Product Name | Mindray MEC-1000 Patient Monitor NIBP Pump DZ16330 KPM27C-12E DC 12V 061103C & Electromagnetic Valve |
Brand | Mindray |
Part No | DZ16330 KPM27C-12E DC 12V 061103C |
MOQ | One piece |
Warranty | 90 days |
NIBP Method | Oscillometric |
Mode | MANUAL, AUTO, CONTINUOUS |
Measuring Interval in AUTO Mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480Min |
Resolution Resolution | 1mmHg |
Static pressure accuracy | ± 3mmHg |
Brand Name | Mindray |
Model Number | DZ16330 KPM27C-12E DC 12V 061103C |
View Detail Information
Explore similar products
Center Patient Monitor System Philip MP70 Patient Monitor Mainboard Wholesale
ICU Patient Monitor SPO2 Board Goldway G30 Monitor SPO2 Board M1020-66414 of
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Product Specification
Payment Terms | T/T(wire transfer), Western Union, Paypal | Delivery Time | 3-5 working days |
Packaging Details | Carton | Product Name | Mindray MEC-1000 Patient Monitor NIBP Pump DZ16330 KPM27C-12E DC 12V 061103C & Electromagnetic Valve |
Brand | Mindray | Part No | DZ16330 KPM27C-12E DC 12V 061103C |
MOQ | One piece | Warranty | 90 days |
NIBP Method | Oscillometric | Mode | MANUAL, AUTO, CONTINUOUS |
Measuring Interval in AUTO Mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480Min | Resolution Resolution | 1mmHg |
Static pressure accuracy | ± 3mmHg | Brand Name | Mindray |
Model Number | DZ16330 KPM27C-12E DC 12V 061103C | ||
High Light | Patient Monitor NIBP Pump ,Mindray MEC-1000 Patient Monitor NIBP Pump ,DZ16330 Patient Monitor NIBP Pump |
Mindray MEC-1000 patient monitor NIBP pump DZ16330 KPM27C-12E DC 12V 061103C & electromagnetic valve
NIBP Module
Introduction to the principle
PNI was measured using the oscillometric method. A cuff placed around the upper arm is inflated until the pressure stops blood flow through the arteries in the upper arm. The cuff is then deflated according to the requirements of the algorithm. As cuff pressure decreases, blood flow through the artery is restored, resulting in a corresponding pulsation in the cuff. Consequently, a pressure sensor connected to the cuff inflation hose generates a pulsed signal. The NIBP module can process these signals and deliver measurement results.
Valve drive circuit
Check valve opening/closing. This circuit, along with the motor drive circuit, completes the cuff inflation and deflation operations.
Motor drive circuit
Check the function of the air pump. This circuit, along with the valve drive circuit, completes the cuff inflation and deflation operations. In addition, it provides motor status signals to the A/D converter for detection.
Non-invasive circuit for processing blood pressure signals.
The PNI signal is a difference signal. The differential amplifier circuit amplifies and converts the differential signal into an unbalanced signal and simultaneously sends one signal to the A/D converter and the other signal to the blocking and amplifier circuit. The DC and AMP blocking circuit removes the DC component from the signal, amplifies the signal and sends it to the A/D converter.
Overvoltage detection
NIBP pressure signal detection. Once the pressure exceeds the protection limit, a message is sent to the CPU system and accordingly the CPU system controls the valve drive circuit to open the valve and deflate the cuff, thereby reducing the pressure.
Product Name | Mindray MEC-1000 patient monitor NIBP pump DZ16330 KPM27C-12E DC 12V 061103C & electromagnetic valve
|
Brand | Mindray |
Part No | DZ16330 KPM27C-12E |
Use for | Mindray MEC-1000 patient monitor |
MOQ | One piece |
Warranty | 90 days |
Condition | Work in Good |
Method Mode
| Oscillometric MANUAL, AUTO, CONTINUOUS
|
Measuring Interval in AUTO Mode
| 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480Min
|
Resolution | |
Pressure
| 1mmHg
|
Static pressure accuracy
| ± 3mmHg
|
Accuracy | |
Pressure Maximum Mean error
| ±5mmHg
|
Pressure Maximum Standard deviation
| 8mmHg
|
Overpressure Protection | |
Adult Mode
| 297±3 mmHg
|
Pediatric Mode
| 240±3 mmHg
|
Neonatal Mode
| 147±3 mmHg
|
Thank you so much for your attention .If you're interested in Mindray MEC-1000 Patient Monitor NIBP Pump DZ16330 KPM27C-12E DC 12V 061103C & Electromagnetic Valve ,feel free to contact us .Thank you .
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!