Payment Terms | T/T, Western Union,PayPal |
Delivery Time | 3-5 working days |
Product name | Goldway |
Type | UT4000F |
Application | medical equipment,ICU,hospital device |
Warranty | 90days |
Color | Green |
Stock Status | Sufficient stock |
Product State | Run Well |
Business purposes | Honest and trustworthy |
Mode of transport | Express delivery |
Minimum purchase | 1pcs |
Product Specialty | Durable in use,Pragmatic |
Supported languages | English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,Arabic, German and all the other languages |
After-sale protection | If there are any problems caused by us, we will be free for you to repair or returned |
Primary Competitive Advantages | Professional technical team |
Brand Name | Goldway |
Model Number | UT4000F |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Payment Terms | T/T, Western Union,PayPal | Delivery Time | 3-5 working days |
Product name | Goldway | Type | UT4000F |
Application | medical equipment,ICU,hospital device | Warranty | 90days |
Color | Green | Stock Status | Sufficient stock |
Product State | Run Well | Business purposes | Honest and trustworthy |
Mode of transport | Express delivery | Minimum purchase | 1pcs |
Product Specialty | Durable in use,Pragmatic | Supported languages | English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,Arabic, German and all the other languages |
After-sale protection | If there are any problems caused by us, we will be free for you to repair or returned | Primary Competitive Advantages | Professional technical team |
Brand Name | Goldway | Model Number | UT4000F |
High Light | UT4000F Patient Monitor Main Board ,CW4F4S02A Patient Monitor Main Board |
PHiliphh Goldway UT4000F Patient Monitor Main Board CW4F4S02A
PHiliphh Goldway UT4000F Patient Monitor Main Board CW4F4S02A Patient Monitor Screen Parts
► Brief Introduction
The PHiliphh Goldway UT4000F Main Board CW4F4S02A refers to the central processing unit (CPU) board used in the PHiliphh Goldway UT4000F patient monitor. This main board plays a critical role in processing and displaying patient vital signs, such as ECG, blood pressure, oxygen saturation, and temperature. It also facilitates data storage and communication functions. Overall, the CW4F4S02A main board is an essential component of the PHiliphh Goldway UT4000F patient monitoring system.
► Feature
High resolution display: The main board supports a high-resolution display, providing clear and detailed images for accurate diagnosis and monitoring.
Advanced imaging technology: The board is equipped with advanced imaging technology, such as harmonic imaging, speckle reduction, and tissue harmonic imaging. These technologies improve image clarity and enhance diagnostic accuracy.
Doppler imaging: The main board includes Doppler imaging capabilities, allowing for the assessment of blood flow and vascular conditions.
Multiple transducer compatibility: The board is compatible with a wide range of transducers, enabling flexibility in its use across various clinical applications.
User-friendly interface: The main board features a user-friendly interface with customizable settings, making it easier for healthcare professionals to operate and navigate through the system.
Storage and connectivity options: It provides options for storing and retrieving patient data and images, as well as connectivity to external devices and networks for data transfer and sharing.
Advanced measurement and analysis tools: The board offers a comprehensive set of measurement and analysis tools to aid in diagnosis and treatment planning.
Workflow optimization: The main board is designed to streamline workflow processes, allowing for faster and more efficient examinations.
► Functional
Ensure that you have the necessary tools and equipment to handle the main board safely. This may include an anti-static wrist strap, screwdriver set, and appropriate safety precautions.
Disconnect the power source and any other connected devices from the UT4000F device. This ensures that you are working in a safe environment and prevents any electrical damage.
Open the casing or panel that houses the main board. This may require removing screws or other fasteners. Refer to the user manual or device documentation for specific instructions on disassembling the UT4000F.
Locate the existing main board in the device and disconnect any cables or connectors attached to it. Take note of the specific connections to ensure proper reinstallation.
Carefully remove the old main board from its mounting or slot. Handle it by the edges and avoid touching any sensitive components.
Place the new PHiliphh Goldway UT4000F Main Board CW4F4S02A in the appropriate spot, aligning it with the mounting holes or slots. Be cautious during this process to avoid damaging any delicate parts.
Reconnect any cables or connectors that were previously attached to the old main board onto the corresponding ports of the new main board. Ensure a secure connection by gently pushing the connectors into place.
Secure the new main board in place by fastening any screws or mounting brackets. Double-check that it is properly inserted and aligned before tightening any screws.
Once the main board is securely installed, you can reattach the casing or panel of the UT4000F device. Make sure all screws or fasteners are tightened appropriately.
Reconnect the power source and any other devices that were disconnected earlier. Power on the UT4000F and verify that it is functioning properly.
If needed, configure any settings or perform software updates on the device. Refer to the user manual or documentation for instructions on these additional steps.
► Specification
Power Supply | 110-230 VAC, 50/60Hz |
Input Power | ≤115VA |
SpO2 Measure Range | 50 ~ 100% |
SpO 2 Averaging | 8 second average |
Repeat Cycles | 1 ~ 10, 15, 30, 60, 90, 120 minutes |
Fuses | Two fuse sockets in the rear panel indicated by symbol of fuse, T2.0AL, 250V ~ |
► Company Profile
As a medical equipment expert, we have many years of experience in the production and sales of medical equipment. Our products are of high quality and have always won unanimous praise from customers at home and abroad. We are proficient in medical equipment maintenance technology, and have always been at the forefront of developing the most advanced types of medical equipment and accessories to provide customers and society with the best quality services. We adhere to the concept of win-win cooperation and are committed to protecting the medical device market, providing perfect preferential prices, excellent quality, and reliable services.
Thank you for your time and interest. If you want to explore more details about PHiliphh Goldway UT4000F Patient Monitor Main Board CW4F4S02A, please let us know.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!