China Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module
China Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module

  1. China Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module
  2. China Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module
  3. China Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module
  4. China Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module

Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union,PayPal
Delivery Time 3-5 working days
Product name Mindray
Type 050-000046-00 051-000058
Application medical equipment,ICU,hospital device
Warranty 90days
Product superiority Original
Product conditions In Good working Condition
Nominal Voltage 110V—240v
Index Terms T4000F PRO Multi-parameter Patient Monitor
Material Plastic, PCB, etc
Operation policy Advanced technology, high-quality products, attentive service
Post-sales service Passion in serving our customer with the best service
Features Introduction Practical,Economic,Durable
Stock On sale
Brand Name Mindray
Model Number 050-000046-00 051-000058

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union,PayPal Delivery Time 3-5 working days
Product name Mindray Type 050-000046-00 051-000058
Application medical equipment,ICU,hospital device Warranty 90days
Product superiority Original Product conditions In Good working Condition
Nominal Voltage 110V—240v Index Terms T4000F PRO Multi-parameter Patient Monitor
Material Plastic, PCB, etc Operation policy Advanced technology, high-quality products, attentive service
Post-sales service Passion in serving our customer with the best service Features Introduction Practical,Economic,Durable
Stock On sale Brand Name Mindray
Model Number 050-000046-00 051-000058
High Light 051-000058 SpO2 BoardMPM Module SpO2 Board050-000046-00 SpO2 Board

 

Mindray MPM Module SpO2 Board 050-000046-00 051-000058

 

 

 

► Brief Introduction

The monitor uses the oscillometric method to measure non-invasive blood pressure (NIBP). NIBP measurement is based on the principle that pulsating blood flow in an artery causes oscillations in the arterial wall. Oscillometric devices use a blood pressure cuff to sense these oscillations, which appear as tiny pulsations in the cuff pressure. Oscillometric methods measure mean pressure and determine systolic and diastolic pressures. Oscillometric devices measure the amplitude of the pressure change in the occlusive cuff as the cuff is deflated from above the systolic pressure. When the pulse breaks through the arterial occlusion, the amplitude suddenly increases. As the cuff pressure is further reduced, the pulsation amplitude increases, reaches a maximum value (close to the mean pressure), and then decreases.

 

 

 

Measurement Modes

There are three NIBP measurement modes:

  • Manual: measurement on demand.
  • Auto: repeated measurements at set interval.
  • STAT: continually rapid series of measurements over a five minute period.
  • Sequence: continually automatic measurement at set durations and intervals.

 

 

► Warning

• Be sure to select the correct patient category setting for your patient before NIBP measurement. Do not apply the higher adult settings for pediatric or neonatal patients. Otherwise, it may present a safety hazard.

• Do not measure NIBP on patients with sickle-cell disease or on the limb where skin damage has occurred or is expected.

• Use clinical judgment to determine whether to perform frequent unattended blood pressure measurements on patients with severe blood clotting disorders because of the risk of hematoma in the limb fitted with the cuff.

• Do not use the NIBP cuff on a limb with an intravenous infusion or arterial catheter in place. This could cause tissue damage around the catheter when the infusion is slowed or blocked during cuff inflation.

• Do not apply cuff on the arm on the side of a mastectomy.

• Continuous cuff pressure due to connection tubing kinking may cause blood flow interference, and resulting in harmful injury to the patient.

• NIBP reading can be affected by the measurement site, the position of the patient, exercise, or the patient's physiologic condition. If you doubt the NIBP measurements, determine the patient’s vital signs by alternative means, and then verify that the monitor is working correctly.

• Devices that exert pressure on tissue have been associated with purpura, ischemia, and neuropathy. Inspect the application site regularly to ensure skin quality and inspect the extremity of the cuffed limb for normal color, warmth and sensitivity. If the skin quality changes, or if the extremity circulation is being affected, move the cuff to another site or stop the blood pressure measurements immediately. Check more frequently when making automatic or STAT measurements. Auto NIBP measurements with one and two minute intervals are not recommended for extended periods of time.

• NIBP diagnostic significance must be decided by the physician.

 

 

 

► Specification

Item Default Setting
TXX
(XX refers to temperature site)
Alarm switch On
High limit 38.0 °C
Low limit 35.0 °C
Priority Med
Alarm Outputs Off
ΔT Alarm switch On
High limit 2.0 °C
Priority Med
Alarm Outputs Off

 

 

 

 

Thank you for your time and interest in Mindray MPM Module SpO2 Board 050-000046-00 051-000058

If you want to explore more details please let us know. Any inquiry will be highly appreciated and thanks for your support. Looking forward to receiving your early inquiry.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2015

  • Employee Number:

    20~50

  • Ecer Certification:

    Verified Supplier

China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...

+ Read More

Get in touch with us

  • Reach Us
  • China World Technology Medical Equipment Service Group
  • TianHe District,GuangZhou,GuangDong
  • https://www.patients-monitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement