Payment Terms | T/T(wire transfer), Western Union, Paypal |
Delivery Time | 3-5 working days |
Packaging Details | Carton |
Product Name | P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
Brand | PHiliph |
Part No . | 453564271711 |
Compatible machine | MX400 MX450 MX series |
Condition | Refurbished |
Warranty | 90 days |
MOQ | One piece |
Stock | Sufficient |
Packaging | Carton |
Delivery time | 3-5 working days |
Brand Name | PHiliph |
Model Number | 453564271711 |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Payment Terms | T/T(wire transfer), Western Union, Paypal | Delivery Time | 3-5 working days |
Packaging Details | Carton | Product Name | P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
Brand | PHiliph | Part No . | 453564271711 |
Compatible machine | MX400 MX450 MX series | Condition | Refurbished |
Warranty | 90 days | MOQ | One piece |
Stock | Sufficient | Packaging | Carton |
Delivery time | 3-5 working days | Brand Name | PHiliph |
Model Number | 453564271711 | ||
High Light | P/N 453564271711 Patient Monitor Mainboard ,MX400 Patient Monitor Mainboard ,Mx450 Patient Monitor Mainboard |
P/N 453564271711 PHiliphhilip MX400 Mx450 MX Series Patient Monitor Mainboard
When multiple patients and priorities demand your attention, having comprehensive patient information at a glance can make a real difference. Your monitoring also needs to change with patient acuity and be able to withstand the rigors of in-hospital transport.
The PHiliphhilip IntelliVue MX450 and MX500 monitor a wide range of flexible vital signs and relevant patient data, while giving you portability when you need it. Whether you are in an ICU or a subacute ward, the MX450 and MX500 monitors provide you with the same high standard of patient monitoring as the rest of the IntelliVue family.
It's important to find what you need right away. The IntelliVue MX450 and MX500's 12" touchscreen makes operation simple. You'll also recognize the familiar, easy-to-use interface common across the IntelliVue monitoring portfolio.
Whether you're examining a patient in a bright environment or letting a patient rest with dimmed room lights, you don't need to adjust your monitor's display brightness. Display with ambient light sensor that automatically adjusts screen brightness for readability in virtually any lighting environment
These monitors also feature built-in advanced clinical solutions that provide tools to aggregate and visualize complex clinical data and its interactions. Multiple streams of information are brought together in one intuitive view.
The IntelliVue MX450 uses a multi-measurement module with basic measurement capabilities. The IntelliVue MX500 adds the ability to add additional measurement modules.
Maintenance Task and Test Schedule
Maintenance and Test Schedule | Frequency |
Monitor Tests | |
Safety checks. Selected tests on the basis of IEC 60601-1 | At least every two years, or as needed after repairs to remove or replace the power supply, or when the monitor has been dropped. |
Monitor Maintenance | |
Check ECG synchronization of the monitor and defibrillator (only if hospital protocol requires use of monitor during defibrillation) | At least once every two years, or as needed. |
MX600/700/800 only Replace backlight (integrated displays only) | 25,000 - 30,000 hours (about three years) of continuous usage, or as needed. |
Multi-measurement Module and Module Tests | |
Performance assurance for all measurements not listed below | At least once every two years, or if you suspect the measurement values are incorrect |
Multi-measurement Module and Module Maintenance | |
NBP calibration | At least once every two years, or as specified by local laws. |
Microstream CO2 calibration and performance test | At least once a year or after 4000 operating hours. |
Mainstream and sidestream CO2 calibration and sidestream flow check (M3014A) | At least once a year, or if you suspect the measurement values are incorrect. |
Mainboard
The motherboard contains the CPU, which includes the graPHiliphhilipics processing unit and USB controller. Main memory, system FPGA, system controller including watchdog, and various power supplies are located on this board. In addition, the board contains the MSL interface, recorder interface, ECG Out hardware and various other interfaces.
System information is stored in serial EEPROM to support automatic configuration of the operating system at boot time.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!