China ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K
China ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K

  1. China ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K
  2. China ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K
  3. China ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K
  4. China ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K

ND-782VC Defibrillator Paddle Nihon Kohden TEC-7621 TEC-7631K TEC-7731K

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T(wire transfer), Western Union, Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name ND-782VC Nihon Kohden TEC-7621 Defibrillator Paddle
Brand Nihon Kohden
Part No. ND-782VC
Paddle electrode size for adult 70±3*106±3(mm²)
Paddle electrode size for Children 45± 3*53 ±3(mm²)
Paddle cord length 2.0mm or more (when it is pulled by 18N force )
Approx Size 270mm L x 230mm W x 120mm H
Approx. Weight 0.940Kg / 940g
Condition New and original
Warranty 90 days
Deliver method DHL ,UPS ,Fedex etc
Brand Name Nihon Kohden
Model Number ND-782VC

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T(wire transfer), Western Union, Paypal Delivery Time 3-5 working days
Packaging Details Carton Product Name ND-782VC Nihon Kohden TEC-7621 Defibrillator Paddle
Brand Nihon Kohden Part No. ND-782VC
Paddle electrode size for adult 70±3*106±3(mm²) Paddle electrode size for Children 45± 3*53 ±3(mm²)
Paddle cord length 2.0mm or more (when it is pulled by 18N force ) Approx Size 270mm L x 230mm W x 120mm H
Approx. Weight 0.940Kg / 940g Condition New and original
Warranty 90 days Deliver method DHL ,UPS ,Fedex etc
Brand Name Nihon Kohden Model Number ND-782VC
High Light ND-782VC Defibrillator PaddleTEC-7631K Defibrillator PaddleTEC-7731K Defibrillator Paddle

ND-782VC Nihon Kohden TEC-7621 Defibrillator Paddle

 

Paddle electrode size

For adults :70±3*106±3(mm²)

For children:45± 3*53 ±3(mm²)

Paddle cord length :2.0mm or more (when it is pulled by 18N force )

 

 

 

 

 

Paddle electrode size

For adults :70±3*106±3(mm²)

For children:45± 3*53 ±3(mm²)

Paddle cord length :2.0mm or more (when it is pulled by 18N force )

 

Name

1. contact lamp

2. Charge button

3. Charge lamp

4. Discharge buttoms

 

 

Specification

 

Part NO ND-782
Approx Size 270mm L x 230mm W x 120mm H
Approx. Weight 0.940Kg / 940g

 

 

Removing the paddles

 

1. Make sure the power is turned off.

2. Disconnect the power cord from the electrical outlet and from the defibrillator.

3. Shovels removed. To remove the headstock, press and hold the headstock release button on the headstock connector and pull the headstock connector toward you

 

 

Warning :When removing the vane, pull the vane connector only. Failure to observe this precaution could damage the plate connector or the plate cable.

 

 

 

  • If a memory card is inserted, remove it.

Caution :

Make sure the card eject button is pressed. Otherwise, when the lower case is removed, the buttons may be damaged and the memory card slot will become unusable.

 

 

 

Maintenance

 

 

Maintenance needs are similar whether the defibrillator is monoPHiliphhilipasic or biPHiliphhilipasic, manual or automatic. Preventive maintenance (PM) is staggered annually according to the manufacturer's guidelines.

 

“During PM, the output and integrity of the unit is a major part of our inspection, as well as the function of the entire system,” said David Scott, CBET, Shared Services Biomedical Division at Denver Hospital. "We use a defibrillator tester where we can discharge the defibrillator at different power settings and record the output. Then we can compare the test from a year ago to the test today and see if the power drops, which could indicate There's something wrong with the defibrillator - probably the charging capacitor. Then we'll have to troubleshoot the device."

 

“Defibrillators do not have complex PM or performance verification, but maintaining them is time-consuming because these devices have many functions such as pacing, pulse oximetry and transmission monitoring including electrocardiogram (EKG), non-invasive and invasive blood pressure device," Borowitz said. "So for PHiliphhilipysiological measurements like blood pressure or electrocardiograms, we have the same testing equipment as bedside monitors. We use pacemakers to test pacemaker function."

 

In addition to annual testing, unit staff inspect equipment at the beginning of each shift. After a brief checklist, staff conduct a defibrillation test to confirm that the device is charging properly and to ensure that all necessary supplies, such as electrodes and disposable patches, are present. Make sure there are no loose parts in the cover; all cables to the device are free of cracks, cuts, or broken wires; and cleaning and sanitizing the exterior and connectors is also important for the operation of the device.

 

"Most people have a checkout process that they follow," Scott said. "They might introduce resistance between paddles with decade boxes to simulate patient impedance, but no matter what you're discharging, all defibrillators, monoPHiliphhilipasic or biPHiliphhilipasic, use a 50 ohm non-inductive test load."

 

After a defibrillator is used on a patient, staff at the unit that uses the device are required to perform similar checks before the device is put back into service.

Name

1. contact lamp

2. Charge button

3. Charge lamp

4. Discharge buttoms

 

 

Specification

 

Part NO ND-782
Approx Size 270mm L x 230mm W x 120mm H
Approx. Weight 0.940Kg / 940g

 

 

Removing the paddles

 

1. Make sure the power is turned off.

2. Disconnect the power cord from the electrical outlet and from the defibrillator.

3. Shovels removed. To remove the headstock, press and hold the headstock release button on the headstock connector and pull the headstock connector toward you

 

 

Warning :When removing the vane, pull the vane connector only. Failure to observe this precaution could damage the plate connector or the plate cable.

 

 

 

  • If a memory card is inserted, remove it.

Caution :

Make sure the card eject button is pressed. Otherwise, when the lower case is removed, the buttons may be damaged and the memory card slot will become unusable.

 

 

 

Maintenance

 

 

Maintenance needs are similar whether the defibrillator is monoPHiliphhilipasic or biPHiliphhilipasic, manual or automatic. Preventive maintenance (PM) is staggered annually according to the manufacturer's guidelines.

 

“During PM, the output and integrity of the unit is a major part of our inspection, as well as the function of the entire system,” said David Scott, CBET, Shared Services Biomedical Division at Denver Hospital. "We use a defibrillator tester where we can discharge the defibrillator at different power settings and record the output. Then we can compare the test from a year ago to the test today and see if the power drops, which could indicate There's something wrong with the defibrillator - probably the charging capacitor. Then we'll have to troubleshoot the device."

 

“Defibrillators do not have complex PM or performance verification, but maintaining them is time-consuming because these devices have many functions such as pacing, pulse oximetry and transmission monitoring including electrocardiogram (EKG), non-invasive and invasive blood pressure device," Borowitz said. "So for PHiliphhilipysiological measurements like blood pressure or electrocardiograms, we have the same testing equipment as bedside monitors. We use pacemakers to test pacemaker function."

 

In addition to annual testing, unit staff inspect equipment at the beginning of each shift. After a brief checklist, staff conduct a defibrillation test to confirm that the device is charging properly and to ensure that all necessary supplies, such as electrodes and disposable patches, are present. Make sure there are no loose parts in the cover; all cables to the device are free of cracks, cuts, or broken wires; and cleaning and sanitizing the exterior and connectors is also important for the operation of the device.

 

"Most people have a checkout process that they follow," Scott said. "They might introduce resistance between paddles with decade boxes to simulate patient impedance, but no matter what you're discharging, all defibrillators, monoPHiliphhilipasic or biPHiliphhilipasic, use a 50 ohm non-inductive test load."

 

After a defibrillator is used on a patient, staff at the unit that uses the device are required to perform similar checks before the device is put back into service.

 

 

If you have any interest in ND-782VC Nihon Kohden TEC-7621 TEC-7631K TEC-7731K Defibrillator Paddle  ,feel free to contact us .

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2015

  • Employee Number:

    20~50

  • Ecer Certification:

    Verified Supplier

China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...

+ Read More

Get in touch with us

  • Reach Us
  • China World Technology Medical Equipment Service Group
  • TianHe District,GuangZhou,GuangDong
  • https://www.patients-monitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement