| Payment Terms | T/T,Western Union,Paypal |
| Delivery Time | 3-5 working days |
| Packaging Details | Carton |
| Product Name | Transducer |
| Compatible with | GE Logiq E9、Logiq P9、Vivid E95、Voluson E10、GE Venue 50 etc. |
| Model | ML6-15-D |
| Array type | Linear |
| Frequency range | 6-15MHz |
| Number of array elements | 256 |
| Maximum effective imaging depth | ≤8cm |
| Application | Small Parts, Pediatrics, Neonatal, Vascular, Breast, Musculoskeletal |
| Cable length | 3.0 meters |
| Insertion and removal lifespan | ≥5000 times |
| Brand Name | GE |
View Detail Information
Explore similar products
Medison NEV4-9ES Ultrasound Transducer Probe For Medison Accuvix V10, SonoAce X8
GE E8C-RS 4D Volumetric Ultrasound Probe with High Resolution for Obstetrics and
GE 11L Linear Array Ultrasound Transducer Probe Used And Good White Metal
GE L6-12-RS 6-12 MHz Linear Array Ultrasound Probe New Original with 90 Days
Product Specification
| Payment Terms | T/T,Western Union,Paypal | Delivery Time | 3-5 working days |
| Packaging Details | Carton | Product Name | Transducer |
| Compatible with | GE Logiq E9、Logiq P9、Vivid E95、Voluson E10、GE Venue 50 etc. | Model | ML6-15-D |
| Array type | Linear | Frequency range | 6-15MHz |
| Number of array elements | 256 | Maximum effective imaging depth | ≤8cm |
| Application | Small Parts, Pediatrics, Neonatal, Vascular, Breast, Musculoskeletal | Cable length | 3.0 meters |
| Insertion and removal lifespan | ≥5000 times | Brand Name | GE |
| High Light | 6-15MHz Ultrasound Probe ,256 Array Elements Ultrasound Transducer ,GE ML6-15-D Linear Array Probe | ||
The GE ML6-15-D is a high-frequency linear array ultrasound imaging probe launched by GE, mainly for the diagnosis of superficial organs and small structures. The probe operates at a frequency of 6-15MHz and has ultra-high resolution. It can image superficial tissues such as thyroid, breast, blood vessels, and muscles and bones, and is a key auxiliary diagnostic device for departments such as endocrinology, breast surgery, and vascular surgery.
1. Superficial Organ Diagnosis
This probe can clearly display the boundaries of thyroid nodules and other structures, helping doctors assess the risk of benign or malignant transformation. It can also identify small lumps in the breast. Suitable for endocrinology, breast surgery, and other departments to improve the detection rate of related diseases.
2. Vascular Ultrasound Diagnosis
Used in cardiology and vascular surgery to assess the degree of vascular stenosis and provide a reference for pre- and post-operative evaluation of vascular interventional procedures.
3. Musculoskeletal System Diagnosis
Used in orthopedics and rehabilitation to diagnose related diseases, providing important information for treatment.
4. Dermatology and Pediatrics Diagnosis
Used in dermatology to diagnose diseases such as eczema and psoriasis. It is also adapted to the physical characteristics of children and can be used in pediatrics to examine various structures in children.
| Name | Transducer |
|---|---|
| Model | GE ML6-15-D |
| Compatible with | GE Logiq E9,Logiq P9,Vivid E95,Voluson E10,GE Venue 50 etc. |
| Array type | Linear |
| Frequency range | 6-15MHz |
| Scanning range | Maximum scanning depth ≤8cm |
| Number of array elements | 256 |
| Applications | Small Parts, Pediatrics, Neonatal, Vascular, Breast, Musculoskeletal |
| Cable length | 3.0 meters |
| Insertion and removal lifespan | ≥5000 times |
Q1: During use, "striped artifacts" are observed in vascular imaging, and adjusting parameters does not improve the situation. What could be the cause?
A1: Artifacts are often caused by uneven application of coupling agent or residual air bubbles. Apply GE's matching coupling agent evenly to the scanning surface and gently press the probe to remove air bubbles. If the artifacts persist, adjusting the probe frequency usually improves image quality.
Q2: After prolonged use, the probe cable shows localized overheating, and the CDFI blood flow signal indicates a lack of blood flow. How should this be handled?
A2: Overheating of the probe cable may be due to an internal conductor short circuit or damage to the shielding layer. Immediately disconnect the cable, stop using it, and check for external damage. Replace the cable if necessary. Abnormal blood flow signals may be due to electromagnetic interference; keep the cable away from high-electromagnetic equipment and recharge.
Q3: When imaging in musculoskeletal mode, the deep fascia layer appears blurry, and adjusting the focus depth does not improve the situation. How can this be resolved?
A3: Reduce the probe frequency and adjust the probe angle to allow the probe to examine deeper layers.
Payment Methods: Bank Transfer / PayPal / Western Union
Shipping Methods: DHL / FedEx
Warranty: 90-day warranty with full after-sales support
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!