Payment Terms | L/C, D/A, D/P, T/T |
Packaging Details | Carton |
Brand | TEPHN |
Color | Metal and glass |
Category | Bulb |
Wattanty | 90 Days |
Packing weight | 1kg |
size | Uniform size |
Application area | Hospitals, private clinics, etc |
Condition | new |
Estimated Ship Time | 3-5 Business Days |
In stock | Enough stock |
Specification | 0.5x0.5cm |
Used for | Biochemical analyzer light |
net weight | 0.5 kg |
Shape | standard |
Brand Name | TEPHN |
Model Number | NT-1000P 12V30W suitable for Neusoft fully automatic biochemical analyzer light source bulb |
Certification | CE/CB/ROSH |
View Detail Information
Explore similar products
Original OSRAM HLX 64610 12V 50W Microscope Slit Bulb 12V 50W
OSRAM HLX 64642 24V 150W Long Life Surgical Shadowless Lamp,Halogen lamp
OSRAM Lamp Cup 64653 HLX ELC 24V250W GX5 New Original ,Die-cast aluminum heat
P/N705-0840 12V 20W Hitachi Biochemical Analyzer 7020 7060 7080 7180 7600 bulb
Product Specification
Payment Terms | L/C, D/A, D/P, T/T | Packaging Details | Carton |
Brand | TEPHN | Color | Metal and glass |
Category | Bulb | Wattanty | 90 Days |
Packing weight | 1kg | size | Uniform size |
Application area | Hospitals, private clinics, etc | Condition | new |
Estimated Ship Time | 3-5 Business Days | In stock | Enough stock |
Specification | 0.5x0.5cm | Used for | Biochemical analyzer light |
net weight | 0.5 kg | Shape | standard |
Brand Name | TEPHN | Model Number | NT-1000P 12V30W suitable for Neusoft fully automatic biochemical analyzer light source bulb |
Certification | CE/CB/ROSH | ||
High Light | Neusoft biochemical analyzer light source bulb ,12V biochemical analyzer light source bulb ,TEPHN biochemical analyzer light source bulb |
Thank you for browsing the TEPHN NT-1000P 12V30W suitable for Neusoft fully automatic biochemical analyzer light source bulb. The light source uses a halogen tungsten lamp as the light source, with up to 16 wavelengths and an effective usage time of not less than 2000 hours. It also uses air cooling and heat dissipation to extend its service life. When the effective time is exceeded or the gain value of the 340nm wavelength is 4.0, it is necessary to replace the light source lamp in a timely manner to ensure the accuracy and stability of the test results. The advantages of this light source are: it can generate strong continuous spectra in some ultraviolet regions and the entire visible light range, with low noise and small drift;
Disadvantages: Short lifespan and time limit.
When the usage time of the light source lamp approaches or reaches its service life, the emitted light intensity will experience energy attenuation, which will affect the detection results.
The light source lamp, as the beam provider in the biochemical analyzer, is crucial in the entire reaction system. Most biochemical analyzers use halogen lamps as the light source, with a working wavelength of 340-804nm. For most enzyme rate based biochemical detection projects, the quality control value changes in a regular manner with the performance changes of the light source lamp. After abnormal curves or results appear, confirmation is needed. At the same time, we need to regularly maintain and calibrate the light source of the biochemical analyzer.
It can be divided into several steps:
1. Maintenance - Routine maintenance - Automatic calibration of photometer
2. Cleaning the color comparison cup: It is necessary to perform a daily cleaning and maintenance of the color comparison cup after turning it on - regular maintenance - cleaning the color comparison cup
3. Cup blank check: Maintenance - Routine maintenance - If the 1 # colorimetric cup displays red or yellow, the photometer needs to be automatically calibrated again.
If in contact with sampling mechanisms, reagent dispensing mechanisms, stirring mechanisms, etc., it may cause injury or infection.
When conducting maintenance checks, please be sure to wear protective tools and follow the order in the user manual. When samples, reagents, etc. adhere to the body, please immediately rinse and disinfect with water, and accept a doctor's diagnosis
Type: | TEPHN NT-1000P 12V30W suitable for Neusoft fully automatic biochemical analyzer light source bulb |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | TEPHN NT-1000P 12V30W |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Metal and glass |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!