Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
ConsentDo not consent
China World Technology Medical Equipment Service Group
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Toshiba PSI-30BX Phased Array Transducer A Used Medical Ultrasound Device With","imgUrl":"https:\/\/img.chinax.com\/nimg\/12\/a7\/76e2d3b3644b6edc3a2c33dcc47d-200x200-1\/toshiba_psi_30bx_phased_array_transducer_a_used_medical_ultrasound_device_with.jpg","attrs":{"Brand Name":"TOSHIBA","Model Number":"PSI-30BX","Minimum Order Quantity":"1","Delivery Time":"3-5 working days"}}
{"title":"Medison NEV4-9ES Ultrasound Transducer Probe For Medison Accuvix V10, SonoAce X8","imgUrl":"https:\/\/img.chinax.com\/nimg\/6e\/24\/428a92526b58459d2bfea92c7497-200x200-1\/medison_nev4_9es_ultrasound_transducer_probe_for_medison_accuvix_v10_2c_sonoace_x8_ultrasound_system.jpg","attrs":{"Brand Name":"Medison","Model Number":"NEV4-9ES","Minimum Order Quantity":"1 Piece","Price":"USD"}}
{"title":"GE 11L Linear Array Ultrasound Transducer Probe Used And Good White Metal","imgUrl":"https:\/\/img.chinax.com\/nimg\/1d\/d9\/486cec5d0a660b1eb934b3df60b5-200x200-1\/ge_11l_linear_array_ultrasound_transducer_probe_used_and_good_white_metal_plastic_for_hospital_2c_clinic_2c_etc.jpg","attrs":{"Brand Name":"GE","Model Number":"11L","Minimum Order Quantity":"1","Price":"USD"}}
{"title":"SuperSonic Ultrasound Machine Linear Vascular Probe SL18-5 Super Linear Array","imgUrl":"https:\/\/img.chinax.com\/nimg\/e2\/cf\/39fc05b00d76698157a9ddf9e711-200x200-1\/supersonic_ultrasound_machine_linear_vascular_probe_sl18_5_super_linear_array_transducer_50mm_5_mhz_to_18_mhz.jpg","attrs":{"Brand Name":"SuperSonic","Model Number":"SL18-5","Minimum Order Quantity":"1","Price":"USD"}}
Toshiba PSI-30BX Phased Array Transducer a used medical ultrasound device with a milky-white exterior and Real-Time Grating Lobe Suppression
Core Components:
Transducer Array: 128-element sectorial crystal array (Frequency: 2~10 MHz), fill factor >85%, supports electronic beam deflection of ±70°.
Host System: Olympus OmniScan X3 platform, supports Total Focusing Method (TFM) and real-time grating lobe suppression.
Toshiba PSI-30BX Phased Array Transducer a used medical ultrasound device with a milky-white exterior. The head of the device features adjustment knobs and is marked with the text "i6sx1," while the tail end has a connector plug. The overall length of the medical device is approximately 1.5 meters.
It is equipped with a curved probe head designed for general imaging of mid-to-deep anatomical structures. The small surface area of the probe allows for easy scanning of the entire heart through the intercostal spaces, producing clear two-dimensional cardiac images. The probe features an ergonomic design with a concave grip for comfortable handling.
This transducer is primarily used for cardiac examinations (e.g., transthoracic echocardiography, TTE). It is operated by hand and requires the use of ultrasound gel. The device is mainly intended for adult patients.
Core Functions:
This ultrasound probe is designed to transmit and receive reflected ultrasonic waves from the human body. It is specifically used for adult cardiac ultrasound examinations.
Cardiac ultrasound examination is a non-invasive diagnostic method that utilizes high-frequency sound waves to penetrate human tissues. These waves are attenuated and reflected back to the device, providing structural information about internal organs.
Usage Instructions:
Follow medical instructions and position the patient in a supine position on the examination table. The patient may need to adjust their posture as directed by the physician to facilitate imaging of different areas.
Brand
TOSHIBA
Application
LOGIQ VOLUSON Series Ultrasound
Model
PSI-30BX
Condition
used
Warranty
90days
Material
plastic
Type
Curved array
Payment
T/T, Western Union, PayPal
Delivery
3-5 days
Safety Precautions
1. It's must use the correct electrical outlet to avoid damage or malfunction.
2. Try to avoid long-term storage, especially in high temperature and high humidity environments.
3. Do not use high-temperature, high-pressure vapour or ionizing radiation as disinfection methods.
4. Do not use chloric disinfectant such as chloride, sodium hypochlorite etc.
5.Before use, ensure the surrounding environment is free from water accumulation, flammable gases, or risks of metal contact to prevent electric shock that could trigger fire or explosion.
6.Ensure the host power is OFF before connecting the probe to prevent transient current damage to the crystal array.
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...