China Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field
China Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field

  1. China Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field

Ophthalmic Digital Fundus SLR Camera One Key Click 135° Wide Field

  1. MOQ: 1
  2. Price: $12,000.00-$13,000.00
  3. Get Latest Price
Payment Terms , T/T
Supply Ability 100
Delivery Time 5 working days
Packaging Details 380mm(L)x550mm(W)x475mm(H)
Product name Non-dilated Digital Fundus Camera
Focus adjustment range ±25D
Weight 26.5Kg
Field View 50°
Working Distance 35mm
Minimum Pupil ≥3.3mm
Shooting light Auto: with shooting mode
Illumination light Infrared led
Brand Name SYSEYE
Model Number RetiCam 3100
Certification FDA
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms , T/T Supply Ability 100
Delivery Time 5 working days Packaging Details 380mm(L)x550mm(W)x475mm(H)
Product name Non-dilated Digital Fundus Camera Focus adjustment range ±25D
Weight 26.5Kg Field View 50°
Working Distance 35mm Minimum Pupil ≥3.3mm
Shooting light Auto: with shooting mode Illumination light Infrared led
Brand Name SYSEYE Model Number RetiCam 3100
Certification FDA Place of Origin China
High Light Ophthalmic Fundus Camera135° Wide Field Fundus CameraDigital Fundus SLR Camera

ophthalmic fundus camera SLR camera one-key click 135° wide field

 

Digital Fundus Camera RetiCam 3100 can be used to capture the anterior and posterior eye images. It has a field of view of 50 degrees for fundus imaging.Digital Fundus Camera Reticam 3100 is a highly recognized and popular automatic fundus imaging system around the world. Through dual camera imaging, image control and feature recognition, eye XYZ 3D automatic positioning is realized. Through CCD imaging feedback, the exposure is measured, and the exposure intensity is automatically and accurately determined, without the need for a doctor's complex operation. By controlling the focusing step length according to the image resolution, the image definition can be automatically adjusted to obtain a clear and accurate fundus image and help doctors make accurate judgments for patients.

 

Field of view 50°
Field of view tolerance ±7%
Resolution  
Center of view ≥60 lp/mm
Field of view center (r/2) ≥40 lp/mm
At the edge of the field of view (r) ≥25 lp/mm
Magnification 1.3 times
Required pupil diameter 4.0 mm or more (3.3 mm or more when using the small pupil shooting function)
Working distance 35 mm
Focus adjustment range ±25D
Shooting light Auto: with shooting mode
  Manual: can be set manually
light source  
Illumination light Infrared led
Shooting light Xenon lights
reflected light  
Scattered light  
camera Digital camera
Fixing light Internal fixing light (LED)
  External fixation light
Moving range  
Stage 90 mm left and right, 35 mm front and rear
Main unit moves vertically 30 mm
Chin-rest tray movement range 60 mm
Rated power supply AC 100V~240V,50/60Hz
size 380 mm(L)x 550 mm(W)x 475 mm(H)
 

 

weight About 26.5kg
When in maximum light intensity/hole bar state
Spectral wavelength 305 nm~1100 nm

 

Equipment classification  
Electric shock protection Class I device

 

Degree of electric shock protection

 

Type B

 

Water-proof protection

 

IPX0

 

Safety level for use in flammable anesthetic gases, oxygen or nitrous oxide mixed with air

 

Not applicable

Standards  

GB 9706.1-2007

IEC 60601-1:1998 + A1:1991 + A2: 1995

Medical electrical equipment - Part 1: General requirements for safety

 

IEC 60601-1:2005

 

Medical electrical equipment - Part 1: General requirements for basic safety and practical performance

 

IEC 60601-1-1:2000

 

Medical electrical equipment - Part 1-1: General requirements for safety - Parallel standard: Safety requirements for medical electrical systems

 

IEC 60601-1-2:2001 + A1:2004

 

Medical electrical equipment - Part 1-2: General requirements for safety - Parallel standard: Electromagnetic compatibility - Requirements and testing

 

IEC 60601-1-2:2007

 

Medical electrical equipment – ​​Part 1-2: Basic safety and

General requirements for practical performance – side-by-side standards: electromagnetic compatibility – requirements and testing

 

 

IEC 60601-1-4:1996 + A1:1999

Medical Electrical Equipment - Part 1-4: Safety General

Seeking – Parallel Standard: Programmable Medical Electrical System

 

IEC 60601-1-6:2010

 

Medical electrical equipment - Part 1-6: General requirements for basic safety and practical performance - Parallel standard: Availability

 

ISO 14971:2007

 

Medical Devices – Risk Management for Medical Devices

 

ISO 15004-1:2006

 

Ophthalmic instruments - Test methods for basic requirements - Part 1: General requirements for all ophthalmic instruments

 

ISO 15004-2:2007

 

Ophthalmic instruments - Test methods for basic requirements - Part 2:

 

ISO 10940:2009

 

Ophthalmic Instruments - Fundus Camera

 

ISO 10993-1:2009 ISO 10993-5:2009 ISO 10993-10:2010

 

Biological evaluation of medical devices

 

IEC 62304:2006

 

Medical Device Software - Software Lifecycle Process

 

IEC 62366:2007

 

Medical Devices – Usability Engineering for Medical Devices

 

GB/T 191-2008

 

Packaging storage and transportation icon

 

GB 4824-2013

 

Industrial, scientific and medical (ism) radio frequency equipment disturbance characteristics limits and methods of measurement

 

GB/T 14710-2009

 

Medical electrical environment requirements and test methods

 

GB/T 16886.1-2011

 

Medical Device Biology Evaluation - Part 1: Evaluation and Testing in Risk Management Process

 

GB/T 16886.5-2003

 

Biological evaluation of medical devices - Part 5: In vitro cytotoxicity test

 

GB/T 16886.10-2005

Biological evaluation of medical devices - Part 10: Stimulation and delayed hypersensitivity test
GB/T 5702-2003 Light source color evaluation method

 

YY 0634-2008

 

Ophthalmic instrument fundus camera

 

YY 0505-2012

Medical electrical equipment - Part 1-2: General requirements for safety - Parallel standard: Electromagnetic compatibility - Requirements and testing

 


 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2011

  • Total Annual:

    20000000-30000000

  • Employee Number:

    200~500

  • Ecer Certification:

    Verified Supplier

Chongqing Bio Newvision Medical Equipment Ltd. Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes ind... Chongqing Bio Newvision Medical Equipment Ltd. Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes ind...

+ Read More

Get in touch with us

  • Reach Us
  • Chongqing Bio Newvision Medical Equipment Ltd.
  • 2nd floor of building #5, 27 Fengsheng Road, Jinfeng Town,High-Tech Industrial Development Zone, 401329 Chongqing, People's Republic of China
  • MrRobert Wang
  • https://www.perimetrymachine.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement