| Delivery Time | 1-30days |
| Item name | pH and ORP controller |
| Detection channel | Two analog channel input |
| Historical data | Can record 10,000 historical data |
| Calibration log | Records the last 100 times |
| Relay output | 2 configurable SPST relays |
| Current output | 2 channel 0/4~20mA |
| communication interface | RS485 interface MODBUS RTU |
| Protection grade | IP66 |
| Operating environment | 0~60℃ |
| Storage environment | 20~70℃ |
| Instrument dimensions | 144*144*120mm |
| Installation method | Wall mounting, pipe clamp, panel |
| Shell Material | Reinforced ABS |
| Power requirements | AC: 100~240V, 50~60Hz; DC: +18~36V |
| Brand Name | Daruifuno |
| Model Number | APX2-PD |
| Certification | ISO, CE |
| Place of Origin | China |
View Detail Information
Explore similar products
24VDC IP66 Industrial Online PH ORP Transmitter With 2 SPST Relays
Differential Signal Input RS485 Online PH ORP Controller 100 ~ 240V AC
RS485 ± 2000mV Digital PH ORP Meter ABS Shell Water Treatment
14pH RS485 Online ORP PH Controller Stable Measuring Meter For Various
Product Specification
| Delivery Time | 1-30days | Item name | pH and ORP controller |
| Detection channel | Two analog channel input | Historical data | Can record 10,000 historical data |
| Calibration log | Records the last 100 times | Relay output | 2 configurable SPST relays |
| Current output | 2 channel 0/4~20mA | communication interface | RS485 interface MODBUS RTU |
| Protection grade | IP66 | Operating environment | 0~60℃ |
| Storage environment | 20~70℃ | Instrument dimensions | 144*144*120mm |
| Installation method | Wall mounting, pipe clamp, panel | Shell Material | Reinforced ABS |
| Power requirements | AC: 100~240V, 50~60Hz; DC: +18~36V | Brand Name | Daruifuno |
| Model Number | APX2-PD | Certification | ISO, CE |
| Place of Origin | China |
Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment
Daruifuno brand APX2-PD dual-channel controller usually supports simultaneous connection of one analog pH electrode and one analog ORP (oxidation-reduction potential) electrode, or two analog pH sensors and two analog ORP sensors. The pH value and oxidation-reduction potential (mV value) of the solution are collected respectively. The internal analog circuit converts the electrode signal into a standard voltage signal, amplifies and filters it, and then the microprocessor of the controller performs numerical processing and judgment, thereby outputting a relay control signal or an analog current (such as 4-20mA) signal.
pH channel: measures pH (0-14) and controls acid/base dosing.
ORP channel: measures oxidation-reduction potential (±2000mV) for disinfection (such as chlorination) or dechlorination.
The electrode is connected to the controller terminal; the controller relay output is connected to the dosing pump, alarm or cleaning device; the control logic, calibration, cleaning cycle, etc. can be set through the menu; regular calibration and data viewing are supported.
Product Parameters
| Model | APX2-PD-A | APX2-PD-D | |
| Measuring Objects | 2 measurement channel inputs, pH or ORP can be selected arbitrarily | ||
| Principle | PH | Glass pH electrode (hydrogen ion concentration index) | |
| ORP | Platinum or gold electrodes (redox potential) | ||
| Display Range | PH: 0~14pH ORP: ± 2000mV Temp: -10~150℃ | ||
| Resolution | PH: 0.01pH ORP: 1mV TEMP: 0.1℃ | ||
| Accuracy | 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one | ||
| Stability | 0.05% of measuring range every 24 hours without accumulation | ||
| Repeatability | Better than 0.1% of measuring range | ||
| Temp. Compensation | Automatic or manual (NTC10K/PT1000) | ||
| Relay Output | Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp. or clean control | ||
| Digital Communication | A two-wire RS485 interface, Modbus RTU and JSON | ||
| Current Output | Two 0/4~20mA current Max. load 1000Ω | ||
| Time Display | Year/month/date hour/minute/second | ||
| Historical Data | Record 10000 historical data and the last 100 calibration maintenance data | ||
| Valuation Object* | Built-in matrix (equivalent to residual chlorine) 0~2.5mg/L | ||
| Support user-defined (20x20 matrix) | |||
| Linear correspondence (water sample stability) | |||
| Display | 128*64 3.2-inch graphic dot matrix LCD | ||
| Calibration Method | PH: 3 points ORP: 2 points, calibration points can be set freely | ||
| Material | Enhanced ABS Protection Grade: IP66 | ||
| Power Supply | AC: 100~240V 50/60Hz | DC: 18~36V | |
| Dimension | 144*144*120mm (Hole size 138*138mm) | ||
| Work Temperature | 0~60℃, RH<95%, non-condensing | ||
| Storage Temperature | -20~70℃, RH<55%, non-condensing | ||
| Installation | Wall mounting, pipe clamp, panel | ||
Advantages and features
Daruifuno PH ORP controller APX2-PD history record and electronic clock function1. History recording function
1.Store measurement data, alarm events, etc.
Recording interval can be set (such as every 10 minutes)
2. Electronic clock function
Real-time clock module to ensure accurate event recording time
![]()
![]()
Daruifuno PH ORP controller APX2-PD two-way relay control dosing principle
Set the pH upper/lower limit. When the set value is exceeded, the relay will be activated.
Example: pH > 9, start the acid dosing pump;
pH < 6, start the alkali dosing pump;
You can set the hysteresis interval to avoid frequent switching.
![]()
Daruifuno PH ORP controller APX2-PD automatic cleaning control principle
The cleaning relay can be set to start at a fixed time (such as every 24 hours); the flushing time setting
starts the solenoid valve or water pump to clean the electrode
avoids measurement errors caused by adhesion on the electrode surface.
![]()
Daruifuno PH ORP controller APX2-PD pH and ORP calibration method
1. pH calibration:
Use standard buffer: pH 4.01, 7.00, 10.01, PH ORP controller produced by our company Daruifuno, the calibration point can be set freely.
Single point calibration: Use pH 7.00 liquid to calibrate the zero point.
Two-point calibration: pH 7.00 and 4.00 or 10.00, calibrate the zero point and slope.
The controller guides the operation, automatically determines stability and stores.
2. ORP calibration:
Use standard buffer, such as +220mV or +470mV.
The calibration process is simple, usually a single point is sufficient.
![]()
![]()
Daruifuno PH ORP controller APX2-PD controller installation methodInstallation method:
Panel installation (opening installation, IP66 protection panel)
Wall installation (adaptive protection shell)
Pipeline installation
Installation environment:
Avoid direct sunlight, high temperature and high humidity;
Cables are routed separately to avoid sharing the same wiring trough with power lines;
![]()
![]()
Aplication:
◇ Surface water
◇ Source water
◇ Aquaculture waters
◇ Landscape water
◇ Import of the waterworks
◇ Water treatment monitoring
◇ Drinking water,
◇ Groundwater, swimming pool
◇Industrial process monitoring and dosing control management
◇Chemical, petroleum, paper, food and medicine, electroplating, PCB manufacturing, etc.
◇ Municipal/industrial water treatment
◇ Circulating cooling water monitoring
◇ Electroplating/chemical liquid control
◇ Food and beverage production line
◇ Acid-base neutralization reaction tank control
![]()
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2015
Ecer Certification:
Verified Supplier
Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ... Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ...