China factories

Chat Now Send Email
China factory - Chengdu Mechan Electronic Technology Co., Ltd

Chengdu Mechan Electronic Technology Co., Ltd

  • China,Chengdu ,Sichuan
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar
China Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar

  1. China Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar
  2. China Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar
  3. China Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar

Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar

  1. MOQ: 1 Piece
  2. Price: USD
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 100000 pieces per year
Delivery Time 5-8 work days
Packaging Details Carton
Feature Minimally-invasive
Function Cutting, hemostasis
Technology Cold RF Plasma
Color Blue
Properties Orthopedic Surgical Instruments
After-sale Service Online Technical Support
Application Knee/Shoulder/Hip joint injury treatment
Brand Name MECHAN
Model Number PLA302
Certification CE, ISO 13485
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 100000 pieces per year
Delivery Time 5-8 work days Packaging Details Carton
Feature Minimally-invasive Function Cutting, hemostasis
Technology Cold RF Plasma Color Blue
Properties Orthopedic Surgical Instruments After-sale Service Online Technical Support
Application Knee/Shoulder/Hip joint injury treatment Brand Name MECHAN
Model Number PLA302 Certification CE, ISO 13485
Place of Origin CHINA
High Light Radiofrequency Plasma Cutting ElectrodeLumbar Puncture Plasma Cutting ElectrodeOrthopedic Surgical Instruments Plasma Electrode

   

                   Mechan Coblation Wand Radiofrequency Plasma Cutting Electrode For Lumbar Puncture

 

01 Detailed Parameters

 

Model No. PLA302
Probe Shape Angle Probe angle 0°/15°/30°
Qty. of pins Cone
Working length 71mm/136mm/86mm
Outer diameter 0.9mm/1.5mm
Usage

Tendinous disease

 

 

Working Temperature: 40-70 Celsius, little thermal damage to surrounding tissues.

With ABLATION and PLACOAG two modes for option.

Online technical guide is always provided.

 

 

02 Indications


Widely used for knee, shoulder, hip, wrist, ankle and elbow joints. Resection, lysis, plasty, debridement and ablation can be applied on meniscus, soft tissue, ligament, synovial membrane, tendon glenoid labrum, etc. For example, complete or partial resection of meniscus, meniscus finishing and repairing, ligament release or tightening, pathological synovial removal, intra-articular residue clearance, agedness osteoarthritis treatment, wound restoring, bone infection treatment, etc.

 

03 Unique Characteristics

  1. Low-temperature resection: less than 70°c
  2. Fibrinogen aggregation hemostasis (clear surgical field and almost no bleeding)
  3. For larger blood vessel: with specialized hemostasis function
  4. Variable-angle joint probe, capable of resection and hemostasis within small articular cavity
  5. Reduce hydrops within articular cavity, almost no soild particles residue
  6. Better and faster recovery of joint function
  7. Low-temperature ablation: less than 50°c
  8. For minimal blood vessel: simultaneously resection and hemostasis
  9. Joint probe with suction tube is capable of suction while resection
  10. Minimize surgery time
  11. Little damage to neighboring tissue, blood vessels and nerves , light pain after surgery
  12. Undertake functions of the power system to a larger extent

04 Thermal Damage Contrast with Laser and Electrosurgical 

 

While most radiofrequency-based surgical products, such as lasers and electrosurgical devices, use imprecise heat-driven processes to remove or cut tissue, our Mechan Plasma creates a controlled, stable plasma field to precisely remove tissue at a low relative temperature, resulting in minimal thermal damage to surrounding soft tissues.

 

 

 

 

 

05 Pain Contrast with Traditional Surgery

 

 

06 Post-op Inflammatory Contrast with Traditional Surgery

 

 

 

* Integrated saline and bipolar energy

Plasma is formed by creating a high density energy field within an electrical conductive fluid, such as saline. A key to sustaining a stable plasma layer is our patented saline delivery system. Without integrated saline, plasma must be formed using the body’s interstitial fluid, which dissipates quickly once energized.Our Mechan Plasma Technology uses bipolar energy to help control the amount of energy and heat delivered to the surrounding tissue.

07 Product Detail Picture

 

 

 

* Controlled, continuous plasma


By combining bipolar energy with continuous saline delivery, our COBLATION technology devices are able to create a stable plasma layer of only 100μm-200μm thick around the active electrode. This allows for the precise excision of tissue while minimizing the heat that is transferred to the patient and ensures a controlled amount of plasma throughout the entire procedure.

 

08 Packaging & Delivery

 

 

Selling Units: Single item
Single package size: 44X17X2 cm
Single gross weight: 0.200 kg
Package Type: by carton

 

09 Certifications

 

 

 

10 FAQ

 

Q1. How about your delivery time?


A: Generally, it will take 1 to 4 weeks after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.

Q2. What is your sample policy?


A: We can supply the sample if we have ready products in stock, but the customers have to pay the sample cost and the courier cost.

Q3. How do you help your distributor sell products?


A: Firstly, We have almost all the necessary certifications to help our distributor to sell Mechan products.
     Secondly, Mechan helps distributors by attending medical fairs in domestic and overseas, such as CMEF every year in China, MEDICA, FIME, Arab Health, etc. and academic conferences in different countries.Mechan helps distributors by attending medical fairs in domestic and overseas, such as CMEF every year in China, MEDICA, FIME, Arab Health, etc. and academic conferences in different countries.

    Thirdly, online technical guide is always provided.


Q4: How do you make our business long-term and good relationship?


A:1. We keep good quality and competitive price to ensure our customers benefit ; We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2002

  • Total Annual:

    100000000-200000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Verified Supplier

Chengdu Mechan Electronic Technology Co., Ltd.   Established in 2002, Mechan Medical is a high-tech medical enterprise with the integration of R&D, manufacture and marketing. It is the pioneer of research, development and manufacturing plasma medical products in mainland China. Mechan... Chengdu Mechan Electronic Technology Co., Ltd.   Established in 2002, Mechan Medical is a high-tech medical enterprise with the integration of R&D, manufacture and marketing. It is the pioneer of research, development and manufacturing plasma medical products in mainland China. Mechan...

+ Read More

Get in touch with us

  • Reach Us
  • Chengdu Mechan Electronic Technology Co., Ltd
  • No. 11, District 9, Huayin Industrial Harbor, No. 618, West Kelin Road, Chengdu Straits Science & Tech Industrial Development Park, Wenjiang District, Chengdu city, Sichuan Province, China. 611130
  • https://www.plasmasurgerysystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement