Payment Terms | L/C, T/T, Western Union |
Supply Ability | 100000 pcs per month |
Delivery Time | 7 working days |
Packaging Details | inner boxes,cartons,pallets |
Valve Series | 2W Series |
Ref. Number | UNI-D Type UW-50 |
Voltage | AC110V AV220V DC24V |
Action | Pilot Diaphragm Drive |
Port Size | 2' Inch |
Media | Water Air Gas |
Fluid Viscossity | Below 20 CST |
Power | Solenoid |
Body Material | Brass |
Diaphragm Material | NBR, FKM and EPDM |
Brand Name | Brando |
Model Number | 2W500-50 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Solenoid Valve For PHILIPS Steam Iron GC8651 GC8616 GC8650
PHILIPS Steam Iron Solenoid Valve 423901709890 292202199016
PHILIPS Steam Generator Iron Solenoid Valve 423901709890 292202199016
PHILIPS Steam Irons Solenoid Valve GC7430 GC8220 GC8225 GC8261
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 100000 pcs per month |
Delivery Time | 7 working days | Packaging Details | inner boxes,cartons,pallets |
Valve Series | 2W Series | Ref. Number | UNI-D Type UW-50 |
Voltage | AC110V AV220V DC24V | Action | Pilot Diaphragm Drive |
Port Size | 2' Inch | Media | Water Air Gas |
Fluid Viscossity | Below 20 CST | Power | Solenoid |
Body Material | Brass | Diaphragm Material | NBR, FKM and EPDM |
Brand Name | Brando | Model Number | 2W500-50 |
Certification | CE | Place of Origin | China |
High Light | 2W Series 2'' Brass Solenoid Valve ,UW-50 Brass Solenoid Valve ,Uni-D Type UW-50 |
2W Series 2'' Inch 2W500-50 UW-50 Water Solenoid Valve
Technical Data of 2W & 2S Solenoid Valve:
2W Series | 2W025-08 | 2W040-10 | 2W160-15 | 2W200-20 | 2W250-25 | 2W350-35 | 2W400-40 | 2W500-50 |
2S Series | 2S025-08 | 2S040-10 | 2S160-15 | 2S200-20 | 2S250-25 | 2S350-35 | 2S400-40 | 2S500-50 |
Orifice Size | 2.5 | 4 | 15 | 20 | 25 | 35 | 40 | 50 |
Port Size | 1/4'' | 3/8'' | 1/2'' | 3/4'' | 1'' | 1-1/4'' | 1-1/2'' | 2'' |
Medium | Water, Air, Gas, Oil | |||||||
Action | Direct Acting | Semi-Direct Diaphragm Operated | ||||||
Function | 2 Way, Normally Closed | |||||||
Fluid Viscosity | 20 CST below | |||||||
Pressure Range | 0 to 1.0 Mpa | |||||||
Temp. Range | -5 to +85℃ |
Main dimension of 2W & 2S Series Solenoid Valves:
2S Series | 2W Series | A | B | C | D | E |
2S025-06 | 2W025-06 | 64.5 | 30 | 75 | 43 | 1/8'' |
2S025-08 | 2W025-08 | 64.5 | 30 | 75 | 43 | 1/4'' |
2S040-10 | 2W040-10 | 70.6 | 32 | 82.4 | 53 | 3/8'' |
2S160-10 | 2W160-10 | 101.5 | 57 | 117 | 69 | 3/8'' |
2S160-15 | 2W160-15 | 101.5 | 57 | 117 | 69 | 1/2'' |
2S200-20 | 2W200-20 | 107 | 57 | 123.5 | 73 | 3/4'' |
2S250-25 | 2W250-25 | 111.5 | 73.5 | 134.5 | 99 | 1'' |
2S350-35 | 2W350-35 | 142 | 95 | 172 | 123 | 1-1/4'' |
2S400-40 | 2W400-40 | 142 | 95 | 172 | 123 | 1-1/2'' |
2S500-50 | 2W500-50 | 172 | 123 | 209 | 168 | 2'' |
Pilot Diaphragm:
In certain cases an internally piloted valve will require a minimum line pressure to insure sealing of the main orifice. This is due to the fact that the diaphragm is usually produced in a flat fashion and is made of some type of elastomeric material which will have a tendency to pull the diaphragm back to its normal position. External Pilot Operated Valves - With these types of valves, an independent external pilot source is used for controlling the pressure for actuation purposes. These valves are either piston or diaphragm types and may be actuated by either air or liquids.
A 3-Way solenoid pilot valve controls the independent external pilot media. In the case of externally piloted valves, the standard internal pilot valves are manipulated in a manner which separates the main valve into two sections. The upper section is the pilot pressure chamber and the lower section is for main media control. In the normal position, with pilot pressure, the main valve is closed preventing the flow of media. Pilot pressure is interrupted when the solenoid is energized. The plunger is pulled from its normal position to the raised position, closing off the pilot inlet orifice. At the same time the pressure is released from the pilot chamber of the valve by means of an exhaust port. When the solenoid is de-energized, the plunger returns to its normal position closing the exhaust port and the pilot pressure again builds in the pilot chamber, creating the diaphragm closing force. (Note - All externally piloted valves will fail to open if for some reason the pilot supply pressure is interrupted).
The Normally Open and closed functions of the main valve rely on the function of the pilot valve. For example, a Normally Closed external pilot valve requires a Normally Open pilot valve. Conversely, a Normally Open external pilot valve requires a Normally Closed pilot valve.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2008
Total Annual:
8million-9million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years. * We have served customers fr... * Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years. * We have served customers fr...
Get in touch with us
Leave a Message, we will call you back quickly!