China factories

China factory - Ningbo Sanmin Import And Export Co.,Ltd.

Ningbo Sanmin Import And Export Co.,Ltd.

  • China,Ningbo ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust
China Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust

  1. China Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust
  2. China Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust
  3. China Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust
  4. China Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust

Sanmin QG-Z-15 76S Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust

  1. MOQ: 20
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10000 PCS
Delivery Time Negotiation
Packaging Details Plastic Bags , Boxes , Carton , Pallet Or As Customer Advice
Pressure 0 . 3 - 0 . 6MPa
Temperature - 25 ~ 60 ℃
Relative Humidity ≤ 85 %
Medium Clean Air
Voltage AC220V / DC24V / AC110V / AC24V Customized
Body ADC 12 Die Cast
Port size G1/2 G3/4 G1 G1-1/2 G2 G2-1/2 G3
Brand Name NBSANMINSE
Model Number QG - Z - 15 / 20 / 25 / 40S / 50S /62S /76S
Certification ISO9001
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10000 PCS Delivery Time Negotiation
Packaging Details Plastic Bags , Boxes , Carton , Pallet Or As Customer Advice Pressure 0 . 3 - 0 . 6MPa
Temperature - 25 ~ 60 ℃ Relative Humidity ≤ 85 %
Medium Clean Air Voltage AC220V / DC24V / AC110V / AC24V Customized
Body ADC 12 Die Cast Port size G1/2 G3/4 G1 G1-1/2 G2 G2-1/2 G3
Brand Name NBSANMINSE Model Number QG - Z - 15 / 20 / 25 / 40S / 50S /62S /76S
Certification ISO9001 Place of Origin CHINA
High Light electromagnetic pulse valvepulse air valve

Sanmin QG-Z-15 Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust Proof Baghouse application GOYEN Type

 

 

 


Technical Parameter                                                                                                                                     

 

  Right angle Embedded Inline Plug
Design-pressure 0.3~0.8MPa 0.2~0.8MPa 0.3~0.8MPa 0.2~1.0MPa
Working-pressure 0.3~0.6MPa 0.2~0.6MPa 0.3~0.6MPa 0.2~0.6MPa
Ambient Temperature -25~60℃ Customized for lower or higher temperature
Relative Humidity ≤85%
Working Medium Clean Air
Voltage AC220V/DC24V/AC110V/AC24V Customized
Protection Class IP65
Diaphragm Life Over One Million Cycles
Cv/Kv Call us for detail

 


Material Construction :                                                                                                                                  

 

Body : ADC12 die cast

Armature : 430 FR stainless steel

Diaphragm : Nitrile or Viton

Spring : 321 stainless steel

Fasteners : 302 stainless steel


 

Use period Failure phenomena Possible Reason Troubleshooting
During installation and commissioning The valves cannot all be opened, but the leading part does act. Check the gas dome pressure to see if it is too low. Check the leakage
Some valves do not work, but the others are normal. Check the valve coil connection and coil Replace the accessories
The valves cannot all be closed. There is leakage. There is no way to establish a gas dome. Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves. Check the leakage
Z-valve. The valve inlet and blowing muzzle are installed backwards. Re-install
Some valves cannot be closed. There is leakage. There is some dirt or debris on the membrane, ii is blocking the moving iron core. Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
A valve closing is slowly. The membrane orifice is blocked. Dredge the membrane orifice
During use period

Some valves are leaking. The membrane cannot close tightly and the valve is always open a

little.

There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked. Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
Coil is hot and burned out. It has been turned on for too long. Check the working condition of the control system.
Voltage exists but the valve does not operate. Membrane is damaged and the orifice is blocked. Replace the accessories in time.
Ambient temperature is below -20℃. The valve is leaking and cannot open. Ambient temperature is too low and here is frost in the valve. Pay attention to insulation and maintaining proper temperatures.


 

Our products are high quality with 12 month guarantee ,and support paypal payment.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company

  • Year Established:

    2014

  • Total Annual:

    2000000-3000000

  • Employee Number:

    40~60

  • Ecer Certification:

    Verified Supplier

NINGBO SANMIN IMPORT & EXPORT CO.,LTD. was established in 2014.Our company is mainly engaged in instrumentation, pneumatic and hydraulic industry accessories and services, has more than 10 series of core products.Focusing on the production of automatic machinery to provide a variety of options, ... NINGBO SANMIN IMPORT & EXPORT CO.,LTD. was established in 2014.Our company is mainly engaged in instrumentation, pneumatic and hydraulic industry accessories and services, has more than 10 series of core products.Focusing on the production of automatic machinery to provide a variety of options, ...

+ Read More

Get in touch with us

  • Reach Us
  • Ningbo Sanmin Import And Export Co.,Ltd.
  • 浙江省宁波市奉化区萧王庙街道科程小微企业园1幢303
  • https://www.pneumaticsolenoid-valve.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement