Switching element | microswitch |
Ambient temp. | -20℃-60℃ |
Medium temp. | 0℃-80℃ |
Repeatability error | ≤1% |
Brand Name | NBSANMINSE |
Model Number | TXK |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
TL1102 pressure switch (anti-corrosion medium pressure) pressure controller
TXK pressure controller
TXK Explosion proof Pressure Controller
TXK differential pressure controller
Product Specification
Switching element | microswitch | Ambient temp. | -20℃-60℃ |
Medium temp. | 0℃-80℃ | Repeatability error | ≤1% |
Brand Name | NBSANMINSE | Model Number | TXK |
Certification | CE | Place of Origin | CHINA |
1, Overview
TXK differential pressure switches can be widely used in large, medium, and small air-cooled or water-cooled chillers using plate heat exchangers, sleeve heat exchangers, and shell and tube heat exchangers for water flow control and monitoring of pump and water filter status. It is also widely used in gas detection, non corrosive media, measuring absolute pressure, and gauge pressure, and is widely used in air conditioning and clean rooms, fan and filter blowing control, fluid and liquid level control.
2, Technical performance
Working viscosity | 1x10-3m2/s |
Switching element | microswitch |
Enclosure ratings | IP65 |
Ambient temperature | -20℃-60℃ |
Medium temperature | 0℃-80℃ |
Anti-Vibration Performance | Max 20m/s² |
Repeatability error | ≤1% |
Contact capacity | Max 220V AC, ≤5A |
3, Specifications
Adjustment range of pressure setting value
| Switching difference not greater than
| **Allowable pressure (Mpa)
| External dimensions | Switching frequency/minute
| Membrane material | Internal thread of interface
|
0.5-3KPa | 0.2KPa | 1 | 01 | 15 | Stainless steel or rubber | NPT1/4 |
1-10KPa | 0.5KPa | 1.2 | 01 | 15 | Stainless steel or rubber | NPT1/4 |
1-16KPa | 1.5KPa | 1.5 | 01 | 15 | Stainless steel or rubber | NPT1/4 |
25~105KPa | 1.8KPa | 3.5 | 01 | 15 | Stainless steel or rubber | NPT1/4 |
20~200KPa(RN) | 2KPa | 5 | 01 | 15 | Stainless steel or rubber | NPT1/4 |
4, Selection Table
TXK - □ □ - □ - □ - □ 1 2 3 4 5 | |||||
1. Product Form | |||||
01 | convention | 02 | double-contact | 03 | EEx d |
04 | Lower differential pressure | 05 | Upper and lower differential pressure | 06 | High hydrostatic pressure |
07 | furnace | ||||
2. Shell | |||||
NN | Regular style | RN | Dual contact model | LC | Ordinary explosion-proof model |
B | Explosion proof model with small viewing window | AL | Furnace shell | ||
3. Diaphragm type | |||||
01 | poly | 02 | stainless steel | 03 | rubber |
4. Connecting thread (customizable as needed) | |||||
01 | NPT1/4 内 | ||||
5. Range | Refer to the detailed range selection table | ||||
Selection example: TXK-05NN-02-01-009 TXK differential pressure controller, product form: upper and lower differential pressure, housing: ordinary type, diaphragm form: stainless steel, connection thread: NPT1/4 internal, range: 5-210KPa. |
Range comparison table
Code | Range | Notes | Code | Range | Notes |
001 | 3.5-27.5MPa | Conventional pressure | 002 | 1.2-12MPa | Conventional pressure |
003 | 0.7-7MPa | Conventional pressure | 004 | 0.37-3.7MPa | Conventional pressure |
005 | 0.25-2.5MPa | Conventional pressure | 006 | 0.15-1.2MPa | Conventional pressure |
007 | 20-700KPa | Conventional pressure | 008 | 10-350KPa | Conventional pressure |
009 | 5-210KPa | Conventional pressure | 010 | 5-170KPa | Conventional pressure |
011 | 0-100KPa | Conventional pressure | 012 | ﹣100-0KPa | Conventional pressure |
013 | ﹣100-100KPa | Conventional pressure | 014 | 25KPa | High hydrostatic pressure |
015 | 0-60KPa | Lower differential pressure | 016 | 20-200KPa | Lower differential pressure |
017 | 50-500KPa | Lower differential pressure | 018 | ﹣0.5-0.5KPa | Furnace differential pressure |
019 | ﹣3-3KPa | Furnace differential pressure | 020 | ﹣6-6KPa | Furnace differential pressure |
021 | ﹣12-12KPa | Furnace differential pressure |
5, Debugging method and switch wiring diagram
Return the adjusting nut to a state of basic weakness, connect the C, NO, NC wires of the switch to the signal light. Observe the status of the signal light, connect the signal light to a green light (C is the common terminal, and when C is connected to NC at the factory, the green light will light up), and adjust the adjusting nut up and down according to the set point indicator to set it to the desired set point. (The downward pressure increases, the upward pressure decreases)
6, Appearance and installation dimensions
01
Company Details
Business Type:
Manufacturer,Importer,Exporter,Trading Company
Year Established:
2014
Total Annual:
2000000-3000000
Employee Number:
40~60
Ecer Certification:
Verified Supplier
NINGBO SANMIN IMPORT & EXPORT CO.,LTD. was established in 2014.Our company is mainly engaged in instrumentation, pneumatic and hydraulic industry accessories and services, has more than 10 series of core products.Focusing on the production of automatic machinery to provide a variety of options, ... NINGBO SANMIN IMPORT & EXPORT CO.,LTD. was established in 2014.Our company is mainly engaged in instrumentation, pneumatic and hydraulic industry accessories and services, has more than 10 series of core products.Focusing on the production of automatic machinery to provide a variety of options, ...
Get in touch with us
Leave a Message, we will call you back quickly!