China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper
China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper

  1. China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper
  2. China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper
  3. China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper
  4. China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper
  5. China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper
  6. China RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper

RVV 5x4.0mm2 5 Core Flexible Cable PVC Multi Circuit Strand Flexible Copper

  1. MOQ: 1 Meter
  2. Price:
  3. Get Latest Price
Insulation PVC (polyvinyl chloride), nominal thickness 0.8 mm, colours: brown, blue, black, grey, yellow/green​ (typical 5-core colour coding)
Design outer diameter ≈ 15.5 mm
Packaging Details General Packaging or As Requirements
Outer sheath PVC​ (polyvinyl chloride), nominal thickness 1.2 mm (typical), colour: black​
Conductor class Class 5 flexible
Overall cable diameter 14 – 17 mm
Filler & bedding minimal
Conductor construction 56×∅0.30 mm (typical)
Supply Ability 100000 meters per month
Number of cores 5
Insulation thickness 0.8 mm
Outer sheath thickness 1.2 mm
Design weight ≈ 465 kg/km
Filler PVC filler or jute, round profile
Conductor (×5) Copper, Class 5 fine-stranded flexible, nominal 56×∅0.30 mm (4.0 mm²), conductor Ø ≈ 3.0 mm
Approx. weight 0.42 – 0.52 kg/m (420–520 kg/km)
Inner bedding PVC tape wrap (optional)
Cable shape Round
Payment Terms L/C,T/T
Conductor nominal area 4.0 mm² (Cu, flexible)
Diameter over insulated core (approx.) 4.6 mm
Delivery Time Less than 15 days
Conductor material Copper (Cu)
Conductor diameter (approx.) 3.0 mm
Model Number RVV 5x4.0mm²
Certification CE/ISO/CCC
Brand Name TONGDU
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Insulation PVC (polyvinyl chloride), nominal thickness 0.8 mm, colours: brown, blue, black, grey, yellow/green​ (typical 5-core colour coding) Design outer diameter ≈ 15.5 mm
Packaging Details General Packaging or As Requirements Outer sheath PVC​ (polyvinyl chloride), nominal thickness 1.2 mm (typical), colour: black​
Conductor class Class 5 flexible Overall cable diameter 14 – 17 mm
Filler & bedding minimal Conductor construction 56×∅0.30 mm (typical)
Supply Ability 100000 meters per month Number of cores 5
Insulation thickness 0.8 mm Outer sheath thickness 1.2 mm
Design weight ≈ 465 kg/km Filler PVC filler or jute, round profile
Conductor (×5) Copper, Class 5 fine-stranded flexible, nominal 56×∅0.30 mm (4.0 mm²), conductor Ø ≈ 3.0 mm Approx. weight 0.42 – 0.52 kg/m (420–520 kg/km)
Inner bedding PVC tape wrap (optional) Cable shape Round
Payment Terms L/C,T/T Conductor nominal area 4.0 mm² (Cu, flexible)
Diameter over insulated core (approx.) 4.6 mm Delivery Time Less than 15 days
Conductor material Copper (Cu) Conductor diameter (approx.) 3.0 mm
Model Number RVV 5x4.0mm² Certification CE/ISO/CCC
Brand Name TONGDU Place of Origin China
High Light RVV 5 Core Flexible Cable ,5x4.0mm2 5 Core Flexible Cable ,Circuit multi strand flexible copper cable

RVV 5x4.0mm2 5 Core Flexible PVC Stranded Copper Cable 300/500V Multi Circuit

Cable Designation & Meaning

Code

Meaning

R

Flexible conductor (Class 5 fine-stranded copper)

V

PVC (polyvinyl chloride) insulation

V

PVC (polyvinyl chloride) outer sheath

5×4.0 mm²

Five cores, each 4.0 mm² flexible copper


Construction: Fine-stranded tinned or plain copper conductor, PVC insulation, PVC sheath, five-core flexible power cable.




RVV-5×4.0 mm² (flexible PVC-sheathed 5-core cable, 3P+N+PE) — Specification & Engineering Data

1. Overview & Ratings. RVV-5×4.0 — copper PVC-insulated PVC-sheathed flexible cable, five 4.0 mm² Class 5 stranded copper cores, PVC inner insulation, one PVC outer sheath, rated 300/500 V AC, 50 Hz; built and tested per GB/T 5023 / JB/T 8734, stranding per GB/T 3956. The 5-core configuration (3-phase + neutral + earth) is designed for 3-phase equipment power connections. Ø ≈ 13.5 mm, ≈ 350 kg/km, 100 m coils.

2. Construction Stack (Conductor → Outer Sheath).

Layer Build Wall Diameter
Conductors (×5) Stranded soft Cu, Class 5, 26 × 0.45 mm per core — ≈ 2.8 mm each
Inner insulation (×5) PVC, colour-coded (R/Y/B/light blue/green) 0.7 mm ≈ 4.2 mm each
Lay-up 5 cores twisted together, filler — ≈ 10.5 mm
Outer sheath PVC, black/grey 1.5 mm ≈ 13.5 mm (finished)


3. Electrical Characteristics. R ≤ 4.61 Ω/km per core at 20 °C; routine test 2.0 kV AC / 5 min between cores; insulation resistance ≥ 0.012 MΩ·km. Reference ampacity (5 cores loaded) ≈ 25 A per core in free air at 30 °C; ≈ 21 A in conduit. Voltage drop ≈ 1.2 V per 100 m at 25 A.

Insulation & Sheath Data

Property

Value

Material (insulation)

PVC (polyvinyl chloride)

Material (sheath)

PVC (polyvinyl chloride)

Insulation nominal thickness

0.8 mm

Sheath nominal thickness

1.2 mm

Long-term service temp.

70 °C​ (continuous)

Short-circuit temp. (≤5 s)

160 °C​ (Cu conductor limit)

Emergency overload temp.

90 °C (short term)

Weather resistance

Limited — indoor/dry use; not UV-resistant

Flame retardant

IEC 60332-1 (single cable, passes)

Smoke density

Standard (non-low-smoke)

Halogen content

Contains halogen (PVC)

Oil resistance

Limited (standard PVC)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

GB/T 5023.5 / IEC 60227-5 (light-duty)

Test voltage AC (50 Hz, 5 min)

2000 V

Routine test

DC resistance @20 °C

≤ 4.95 Ω/km

IEC 60228 Class 5 max, 4.0 mm² flexible Cu

AC resistance @70 °C (est.)

≈ 6.30 Ω/km

per core

Capacitance (approx.)

≈ 0.18 µF/km

core to core

Inductive reactance (approx.)

negligible

5-core bundled

Current rating in free air (30 °C)

28 A​

5-core cable, all cores loaded (derated from single-core)

Current rating in conduit (30 °C)

24 A​

5-core, GB/T 16895

Current rating in tray (40 °C ambient)

22 A​

bundled, derated

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.44 kA (440 A)

4.0 mm² Cu

Frequency

50/60 Hz AC

—


Reference values: 4.0 mm² Cu at 24 A, 3-phase 400 V (3P+1N+PE) → max balanced load ≈ 16.6 kVA. Voltage drop at 24 A ≈ 5.9 V/km per core (≈0.26% per 10 m at 400 V).


4. Thermal & Flame Behaviour. 70 °C continuous, 160 °C short-circuit (≤ 5 s); -15~+70 °C ambient, ≥ -15 °C laying; flame-retardant to GB/T 18380 / IEC 60332-1 (self-extinguishing). PVC contains halogen → RVVSP (LSZH) for halogen-free.

Fire Performance (RVV — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)


5. Installation Practice & Handling. Bend ≥ 6 × OD ≈ 80 mm fixed, ≥ 10 × OD ≈ 135 mm flexed; always use ferrules (cord end terminals) for stranded conductors; lay in trunking, tray, conduit, or indoor sheltered locations. Core colours: R/Y/B = L1/L2/L3, light blue = N, green = PE.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 93 mm at Ø15.5 mm

flexible cable

Max. pulling tension

160 N

fine-stranded Cu, use proper grips

Direct burial

Not recommended

unarmoured, PVC not moisture-tight for burial

Conduit ID

≥ 1.5 × OD → ≥ 23 mm; use 25 mm or 32 mm

—

Fixing

cable ties, clips, tray

—

Impact resistance

Low

flexible, not armoured

Water resistance

Limited

indoor/dry only

UV resistance

Poor

not for outdoor exposed

Flex life

Good

suitable for occasional flexing

Termination note

Strip insulation 10–12 mm; use bootlace ferrules or compression lugs

fine-stranded requires proper termination


6. Typical Service Applications. 3-phase equipment power, motor connections, machine tool supply, distribution panel to machinery, industrial automation, pump/compressor power — indoor or sheltered outdoor.



7. Testing & QA Regime. Routine: conductor DC resistance ≤ 4.61 Ω/km, 2.0 kV AC / 5 min withstand, dimensional check (inner insulation ≥ 0.7 mm, sheath ≥ 1.5 mm, OD ≈ 13.5 mm). Type: heat ageing at 100 °C / 168 h, cold bend at -15 °C, heat shock at 150 °C, insulation resistance, flame retardancy per GB/T 18380.


Cable Parameters


RVV-5×4.0 mm² — Copper PVC-Insulated PVC-Sheathed Flexible Cable (5-core 3P+N+PE) — Full Parameter Sheet 
Copper PVC-insulated PVC-sheathed flexible cable · 5 cores × 4.0 mm² Class 5 stranded Cu · PVC inner insulation + PVC outer sheath · 300/500 V · 3-phase + N + PE · GB/T 5023 / JB/T 8734 · finished Ø ≈ 13.5 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVV (Copper PVC-insulated PVC-sheathed flexible cable) — 5-core = 3P+N+PE

Rated voltage (U0/U) 300/500 V AC Control and equipment power

Number of cores 5 × 4.0 — 3-phase + N + PE

Conductor material Annealed stranded soft copper — Class 5 flexible per GB/T 3956

Inner insulation material Polyvinyl chloride (PVC) — PVC-70 °C grade, colour-coded

Outer sheath material Polyvinyl chloride (PVC) — PVC-70 °C grade, black/grey

Outer sheath colour Black / grey — Standard sheath colour

Standard GB/T 5023 / JB/T 8734 — Chinese PVC cable standard
02 · Conductor (Stranded Soft Copper)

Conductor type Stranded soft copper wire — Class 5 flexible per GB/T 3956

Strand construction (per core) 26 × 0.45 mm 26 strands of 0.45 mm each

Conductor diameter (per core) ≈ 2.8 mm Stranded bundle

Cross-sectional area (per core) 4.0 mm² Nominal

DC resistance @ 20 °C (per core) ≤ 4.61 Ω/km Max per GB/T 3956 Class 5

Conductor weight per km ≈ 180 kg/km 5 × 4.0 mm² Cu
03 · Insulation & Sheath

Inner insulation type Polyvinyl chloride (PVC) — PVC-70 °C grade

Inner insulation thickness 0.7 mm Nominal per core

Core colours Red / yellow / blue / light blue / green — L1/L2/L3/N/PE

Outer sheath type Polyvinyl chloride (PVC) — PVC-70 °C grade

Outer sheath thickness 1.5 mm Nominal

Finished outer diameter ≈ 13.5 mm 5 cores laid up + sheath
04 · Electrical

Rated voltage (AC) 300/500 V Control and equipment power

DC resistance @ 20 °C (per core) ≤ 4.61 Ω/km 4.0 mm² Cu Class 5

Insulation resistance ≥ 0.012 MΩ·km PVC at 20 °C

Conductor loss (at 25 A per core) ≈ 2.9 W/m I²R at 70 °C

Routine test voltage (AC) 2.0 kV / 5 min — Power-frequency withstand

Voltage test (AC) 2.0 kV / 5 min — AC withstand test
05 · Thermal

Max continuous conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C PVC limit (≤ 5 s)

Min installation temp. -15 °C Sheathed cable

Service ambient range -15 to +70 °C Indoor / sheltered outdoor

UV resistance Limited — Sheltered outdoor — not direct UV

Halogen-free No — PVC contains halogen

Flame retardancy IEC 60332-1 / GB/T 18380 — Self-extinguishing
06 · Mechanical

Min bending radius (fixed) ≥ 6 × OD ≈ 80 mm 5-core sheathed

Min bending radius (flexed) ≥ 10 × OD ≈ 135 mm Repeated flexing

Tensile strength (insulation) ≥ 10.0 MPa PVC

Abrasion resistance Good — Sheathed
07 · Ampacity

Air ampacity (per core, 5 cores loaded) ≈ 25 A 300/500 V, 30 °C (est.)

Conduit ampacity (5-core) ≈ 21 A In conduit, grouped

Voltage drop (per 100 m @ 25 A) ≈ 1.2 V Per core
08 · Installation

Laying methods Conduit, trunking, tray, indoor fixed, equipment-to-panel — Indoor / sheltered outdoor

Connectors Ferrules, screw terminals, ring fork terminals — Stranded conductor needs ferrules

Polarity Colour-coded cores — R/Y/B=L1/L2/L3, light blue=N, green=PE

Special tools Wire cutter, stripper, ferrule crimper — Standard tools
09 · Packing

Standard supply length 100 m / coil m Flexible cable

Reel / packing type Coil / wooden drum — Standard packaging

Surface marking RVV, 5×4.0, 300/500 V, GB/T 5023, metre marks — Continuous printing

Storage conditions Dry, indoor, -15 to +40 °C — Protect from UV / moisture
10 · Applications

Typical use 3-phase equipment power, motor connections, machine tool supply, distribution panel to machinery, industrial automation, pump/compressor power — Indoor 3-phase equipment

Max system voltage 500 V AC 300/500 V rated

Circuit current rating Up to 25 A per core Per circuit breaker


Test Parameters


Test Parameters — RVV-5×4.0 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C, per core ≤ 4.61 Ω/km (4.0 mm² Cu Class 5) Routine
2 Power-frequency withstand 2.0 kV AC, 5 min, between cores No breakdown Routine
3 Insulation thickness test Micrometer Inner ≥ 0.7 mm, sheath ≥ 1.5 mm Routine
4 Dimensional check Micrometer OD ≈ 13.5 mm Routine
5 Flame retardancy GB/T 18380 / IEC 60332-1 Self-extinguishing Type
6 Heat ageing 168 h at 100 °C No cracking after bend test Type
7 Cold bend test -15 °C, mandrel 6×OD No cracks Type
8 Heat shock 1 h at 150 °C No cracking Type
9 Insulation resistance At 500 V DC, 20 °C ≥ 0.012 MΩ·km Type
10 Conductor continuity Per GB/T 3956 All 5 cores continuous Routine
11 Core colour check Visual R/Y/B/light blue/green cores Routine
12 Sheath integrity Visual + dimensional No damage, OD consistent Routine


Cable Cross Section Structure



RVV-5×4.0 mm² — Cross-Section Construction Diagram (Schematic)
Flexible cable build-up: 5 stranded Cu cores (R/Y/B/light blue/green) → PVC inner insulation → PVC outer sheath · 300/500 V · 3-phase + N + PE · finished Ø ≈ 13.5 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×5) Stranded soft copper, Class 5, 26 × 0.45 mm per core — ≈ 2.8 each 5 cores; R ≤ 4.61 Ω/km
2 Inner insulation (×5) PVC, colour-coded (R/Y/B/light blue/green) 0.7 ≈ 4.2 each 3P+N+PE identification
3 Lay-up 5 cores twisted together, filler — ≈ 10.5 Round lay-up
4 Outer sheath PVC, black/grey 1.5 ≈ 13.5 (finished) Mechanical protection; 70 °C
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 13.5 mm 5 cores laid up + sheath

Approx. cable mass ≈ 350 kg/km 5 × 4.0 mm² Cu + PVC

Nominal voltage rating 300/500 V AC Equipment power / control

Max continuous conductor temp. 70 °C PVC rated

Short-circuit temp. (≤5 s) 160 °C PVC limit

Min installation temp. -15 °C Sheathed cable

Min bending radius (fixed) ≥ 6 × OD ≈ 80 mm 5-core sheathed

DC resistance @ 20 °C (per core) ≤ 4.61 Ω/km 4.0 mm² Cu Class 5

Insulation resistance ≥ 0.012 MΩ·km PVC

Routine test voltage (AC) 2.0 kV / 5 min — Power-frequency withstand

Air ampacity @ 30 °C ≈ 25 A per core 5 cores loaded (est.)

Flame retardancy GB/T 18380 / IEC 60332-1 — Self-extinguishing

Halogen-free No — PVC contains halogen

Core arrangement 3P + N + PE — R/Y/B/light blue/green







Schematic — not to exact scale. Finished Ø ≈ 13.5 mm and weight ≈ 350 kg/km from cross-referenced industry samples; conductor/insulation dimensions per GB/T 5023 and GB/T 3956; ampacity 25 A per core is an engineering estimate for 5 cores loaded in free air. RVV-5×4.0 is a 5-core flexible PVC-sheathed cable (3-phase + N + PE) rated 300/500 V for equipment power and motor connections. Unlike ZC-YJV 4×50 (XLPE 90 °C, 0.6/1 kV, 175 A, 2380 kg/km, Class 2 compacted conductor), RVV uses PVC 70 °C insulation, Class 5 flexible strands, and is designed for smaller 3-phase equipment. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVV-5×4.0 mm² (flexible 5-core cable)
Layer-by-layer flexible 5-core cable build-up · 5 stranded Cu cores (26×0.45) / PVC inner insulation / PVC outer sheath · 300/500 V · 3-phase + N + PE · finished Ø ≈ 13.5 mm
1. Product Identity & Ratings
RVV-5×4.0 is a copper PVC-insulated PVC-sheathed flexible cable rated 300/500 V, built and tested per GB/T 5023 / JB/T 8734. It has 5 colour-coded cores (red/yellow/blue/light blue/green), each 4.0 mm² stranded soft copper (Class 5, 26×0.45 mm), enclosed in a black/grey PVC outer sheath. The 5-core configuration (3-phase + N + PE) makes it suitable for 3-phase equipment power connections. Unlike ZC-YJV 4×50 (XLPE 90 °C, 0.6/1 kV, 175 A, 2380 kg/km), RVV uses PVC 70 °C insulation and Class 5 flexible strands. Finished Ø ≈ 13.5 mm, mass ≈ 350 kg/km, 100 m coils.
2. Stranded Copper Conductors (5 cores)
Each of the 5 cores uses 26 strands of 0.45 mm annealed soft copper (Class 5 flexible per GB/T 3956), giving R ≤ 4.61 Ω/km per core at 20 °C. Core colours: red (L1), yellow (L2), blue (L3), light blue (N), green (PE). The 5-core layout provides all 3 phases plus neutral and earth in one cable — ideal for connecting 3-phase machinery to a distribution panel.
3. PVC Inner Insulation & Outer Sheath
Each core is insulated with 0.7 mm of PVC (PVC-70 °C grade). The 5 insulated cores are laid up and enclosed in a 1.5 mm PVC outer sheath (black/grey). The outer sheath provides mechanical protection. PVC is rated for 70 °C continuous conductor temperature — lower than XLPE (90 °C) in YJV, but sufficient for equipment power at 300/500 V.
4. Flexible vs. Rigid Construction
Unlike ZC-YJV (Class 2 compacted rigid copper, 15×OD bend radius, heavy drum supply), RVV uses Class 5 flexible strands with a small bend radius (6×OD ≈ 80 mm). This makes RVV easy to route inside equipment and between panels. The flexible construction also means the cable can be supplied in coils rather than heavy drums.
5. Site Handling & Operational Notes
• Install in trunking, tray, conduit, or indoor sheltered locations.  • Bend radius 6×OD (≈ 80 mm) fixed, 10×OD (≈ 135 mm) flexed.  • Service -15 to +70 °C.  • Routine test 2.0 kV AC / 5 min.  • PVC contains halogen — use RVVSP (LSZH) for halogen-free.  • At 350 kg/km, supplied in 100 m coils.  • Use ferrules for stranded conductor termination.  • Core colours: R/Y/B=L1/L2/L3, light blue=N, green=PE.



8. Structure Display



9. Packaging, Storage & Logistics. 100 m per coil. Continuous marking: RVV, 5×4.0, 300/500 V, GB/T 5023, supplier identity, production year, metre marks. Store dry, indoor, -15 to +40 °C.


10. Procurement Specification. State "RVV-5×4.0, 300/500 V" + length. Use ferrules for stranded termination. For halogen-free, specify RVVSP-5×4.0 (LSZH). Core colours R/Y/B/light blue/green = 3P+N+PE.


11. Cable Industry FAQ.

  • Q1: What is the difference between RVV-5×4.0 and ZC-YJV 4×50? RVV-5×4.0 is a 5-core flexible PVC cable (300/500 V, 70 °C, Class 5 strands, 25 A, 350 kg/km) for equipment power. ZC-YJV 4×50 is a 4-core XLPE power cable (0.6/1 kV, 90 °C, Class 2 compacted, 175 A, 2380 kg/km) for distribution trunking. Different voltage, temperature, current, and conductor class.
  • Q2: Why 5 cores? A 5-core cable provides 3 phases (L1/L2/L3) + neutral (N) + protective earth (PE) in one sheath — everything needed for a 3-phase equipment connection. No need to run separate earth wire.
  • Q3: When do I need 5 cores vs 4 cores? Use 5-core when the load requires a neutral (e.g. 3-phase equipment with 230 V control circuits). Use 4-core (3P+PE) for 3-phase loads that don't need neutral (e.g. motors).
  • Q4: Can RVV carry 3-phase motor current? Yes — RVV-5×4.0 at 25 A per core can drive small 3-phase motors up to about 11 kW (at 400 V). For larger motors, use YJV (XLPE, higher ampacity).
  • Q5: What is the difference between RVV and RVVP? RVVP adds a copper wire braid screen over the cores. Use RVVP near EMI sources (VFDs, inverters). RVV is unshielded.
  • Q6: Why use Class 5 flexible strands instead of Class 2 compacted? Class 5 (26×0.45) is flexible — easy to route inside equipment and between panels. Class 2 (7×3.0) is rigid — for fixed underground distribution. RVV is for equipment connections; YJV is for fixed distribution.
  • Q7: What is the minimum bending radius? 6 × OD for fixed (≈ 80 mm), 10 × OD for flexing (≈ 135 mm). Much smaller than ZC-YJV 4×50 (15×OD ≈ 430 mm) because RVV is a small flexible cable.
  • Q8: Can RVV-5×4.0 be used outdoors? Only sheltered. For outdoor or burial, use YJV or YJV22 (armored). RVV's PVC sheath is not UV-stable.
  • Q9: What size ferrules do I use? 4.0 mm² cord end terminals (ferrules), crimped with a ferrule crimper. Do not use bare stranded wire without ferrules.
  • Q10: What is the difference between RVV and RVVB? RVV is round (circular cross-section). RVVB is flat (oblong, 2 cores side by side). For 5-core, RVV is always round.
  • Q11: How do I choose between RVV and YJV for equipment? If the equipment is rated 300/500 V or less and the connection is short/flexible, use RVV. If the equipment is rated 0.6/1 kV and the run is long/high-current, use YJV. For 3-phase small equipment, RVV-5×4.0 is the standard choice.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2009

  • Total Annual:

    50000000-100000000

  • Employee Number:

    260~300

  • Ecer Certification:

    Verified Supplier

Company Profile — Anhui Tongdu Cable Co., Ltd. Company Overview Anhui Tongdu Cable Co., Ltd. (hereinafter "Tongdu Cable") is a professional wire and cable manufacturer headquartered in Zongyang Economic Development Zone, Anhui Province, China. Founded in 2009, the company has grown into one of... Company Profile — Anhui Tongdu Cable Co., Ltd. Company Overview Anhui Tongdu Cable Co., Ltd. (hereinafter "Tongdu Cable") is a professional wire and cable manufacturer headquartered in Zongyang Economic Development Zone, Anhui Province, China. Founded in 2009, the company has grown into one of...

+ Read More

Get in touch with us

  • Reach Us
  • Anhui Tongdu International Trade Co., Ltd.
  • Room 2003,B Building,Jiaqiao International Plaza,Baohe District,Hefei City,Anhui Province
  • https://www.power-cabling.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement