| Delivery Time | 4-6 working days |
| Description | Heavy Duty Connector Inserts, Modules RoHS |
| Packaging Details | - |
| Stock | 2 |
| Brand Name | HA-003-MS |
| Model Number | HA-003-MS |
View Detail Information
Explore similar products
TE Connectivity 3-1105150-1
TE Connectivity T1010061400-000
TE Connectivity T2111042101-000
TE Connectivity T2050722201-000
Product Specification
| Delivery Time | 4-6 working days | Description | Heavy Duty Connector Inserts, Modules RoHS |
| Packaging Details | - | Stock | 2 |
| Brand Name | HA-003-MS | Model Number | HA-003-MS |
This specification covers the performance, tests, and quality standards for the contact inserts of heavy-duty connector series HA-003, HA-004, HA-010, HA-016, HA-032 (2x16), HA-048 (3x16), and HA-064 (4x16). The contact inserts are available for positions 3/4/10/16/32/48/64.
The termination conductor-contact insert is achieved via:
| Test ID | Description | Requirement | Test Method | Conditions |
|---|---|---|---|---|
| 3.5.3 | Mating force | Internal connections: 20N max. External connections: 5 x Mating force, but not higher than 80N | IEC 60512-13-5 Test 13e | For unenclosed connector (internal connections); For multi-pole connector, require provision against incorrect mating; For enclosed connector (external connections) |
| 3.5.3 | Pull out force of terminations | See 6.6 of EN 61984 | - | - |
| 3.5.4 a | Visual tests on the crimp barrel and tensile strength test of the crimp connection | The conductor shall not slip out of crimp barrel and pull out force as specified in Table 1 of EN 60352-2 | EN 60352-2 | Only for crimp contact |
| 3.5.4 a | Mechanical tests on the conductor connection | The conductor of the smallest and largest cross-sectional area shall not slip out of the clamping unit, and pull out force as specified in Table 3, and torque force as specified in Table 4 | IEC 60999-1 or IEC 60999-2 | Only for screw contact connection |
| 3.5.4 a | Mechanical tests on the conductor connection | The conductor of the smallest and largest cross-sectional area shall not slip out of the clamping unit, and pull out force as specified in Table 3 | IEC 60999-1 or IEC 60999-2 or IEC 60352-7 | Only for spring clamp connection |
| 3.5.5 | Contact retention force in normal operation, min | 50N force for insert each pin or socket | IEC 60512-15-1 Test 15a | Shift contacts of 1.0mm; Test load applied in axial direction, test speed: 20mm/min; permissible |
| 3.5.6 | Mechanical strength impact | No damage likely to impair normal use. A reduction of clearance and creepage distance is not allowed. | EN 61984 6.18.1 & 6.18.3; IEC 60512-7-2 Test 7b | Dropping height: 750mm for specimens of mass < 250g; 500mm for specimens of mass > 250g. Dropping cycles: 8 positions in 45 step. |
| 3.5.7 | Mechanical Operation (Durability) | Shall be engaged and disengaged by means of a device under normal operating conditions at the speed of approximately 50mm/min | EN 61984 6.14.1; IEC 60512-9-1 Test 9a | 500 operation cycles without load; manual mating/un-mating 300 cycles max. per hour |
| 3.5.8 | Vibration, Random | No discontinuities greater than 1s | EN 61373, Category 1, Class B; IEC 60068-2-6 Test Fc | Frequency: 5~150Hz; Acceleration: 50m/s |
| 3.5.9 | Shock | No damage likely to impair function | EN 61373 | Duration: 30ms; Total 18 shocks (three positive and three negative in each of the three orthogonal axes) |
| 3.5.10 | Contact Resistance | Initial: Max. 5m; Final: < 5 m. The change of contact resistance shall be no more than 50% of the reference value | IEC 60512-2-2 Test 2b | Test current: 1A; Measure points at the end of the termination; Max three contacts per specimen plus protective earthing, if any |
| 3.5.11 | Temperature Rise Test | The sum of the ambient temperature and the temperature rise (T) of a connector shall not exceed the upper limiting temperature | EN 61984 7.3.8; IEC 60512-5-1 Test 5a | Carry its rated current; Upper limiting temperature: 125C |
| 3.5.12 | Dielectric Voltage Withstand Test | No flashover or breakdown of voltage | EN 61984 6.13; 7.3.12 of EN 61984 | Test voltage 1000V DC; Impulse test voltage according to Table 8, applied three impulses of each polarity and interval of at least 1s between impulses |
| 3.5.13 | Insulation Resistance | Not less than 400M | IEC 60512-3-1 Test 3a Method B | Time: 60s |
| 3.5.14 | Cold | No damage likely to impair function | IEC 60512-11-10 Test 11j (IEC 60068-2-1) | -40C Duration time: 16h |
| 3.5.15 | Dry Heat | No damage likely to impair function | IEC 60512-11-9 Test 11i (IEC 60068-2-2) | +125C Duration time: 168h |
| 3.5.16 | Damp Heat, cyclic | No damage likely to impair function | IEC 60512-11-12 Test 11m | Min ambient temperature: 252C; Max ambient temperature: 402C; Number of cycles: 21; Duration time: 12h+12h; Variant 1 |
| 3.5.17 | Rapid Change of temperature (Temperature Cycle) | No damage likely to impair function | IEC 60512-11-4 Test 11d (IEC 60068-2-14 Test Na) | Ta=-402C to Tb=+1252C, duration t1: 1h each extreme, 100 cycles |
Company Details
Business Type:
Manufacturer
Year Established:
2009
Total Annual:
100000000-20000000
Employee Number:
500~600
Ecer Certification:
Verified Supplier
Shenzhen ECER Network Technology Co., Ltd. is a professional supplier specializing in industrial and power connectors for industrial automation, power systems, electrical equipment, control systems, machinery, and other demanding applications. We focus on providing reliable connector solutions for... Shenzhen ECER Network Technology Co., Ltd. is a professional supplier specializing in industrial and power connectors for industrial automation, power systems, electrical equipment, control systems, machinery, and other demanding applications. We focus on providing reliable connector solutions for...
Get in touch with us
Leave a Message, we will call you back quickly!