Payment Terms | T/T, L/C, Western Union |
Supply Ability | 100 Sets Per Month |
Packaging Details | Carton |
Power Source | AC 110V/220V at Customized |
Control | Computer Control |
Loading Method | Dynamic Load |
Display | LCD |
Load Way | Mechanical Load |
Maxcapacity | <1000KN |
Brand Name | Sansion Power |
Model Number | SXFA-AV |
Certification | ISO, SGS, ilac-MRA, CNAS |
Place of Origin | Wuhan, China |
View Detail Information
Explore similar products
Reliable High / Low Voltage Electrical Safety Test Equipment Wireless Phase
Light Weight High Voltage Cable Testing Equipment 20A Accurate Fast Identifying
50A Transformer Power Testing System , DC Winding Resistance Test Equipment
20kVA / 75kV Power Testing System , Full Range AC High Voltage Test Set
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 100 Sets Per Month |
Packaging Details | Carton | Power Source | AC 110V/220V at Customized |
Control | Computer Control | Loading Method | Dynamic Load |
Display | LCD | Load Way | Mechanical Load |
Maxcapacity | <1000KN | Brand Name | Sansion Power |
Model Number | SXFA-AV | Certification | ISO, SGS, ilac-MRA, CNAS |
Place of Origin | Wuhan, China | ||
High Light | power test equipment ,power system test equipment |
CT PT Onsite Power Testing System Current Voltage Transformer
SXFA-AV CT/PT Onsite Test System consists of:
Name | Specification | Quantity |
CT/PT Analyzer | 2.0 degree | 1 Unit |
PT Load Box | 100V | 1 Unit |
CT Load Box | 5A | 1 Unit |
Self Current Injection CT | 2000,5A ,0.02S | 1 Unit |
Self Boosting PT | 10KV,0.02 degree | 1 Unit |
Self Boosting PT | 35KV,0.02 degree | 1 Unit |
Dual Regulating Controller | 5KVA | 1 Unit |
Large Current Leads |
2000 A*3m*1 1000A*3m*2 500A*3m*2 250A*3m*2 100A*3m*2 |
1 Set |
Secondary Current/Voltage Cable | 1 Set | |
CT/PT Calibrating Software | 1 Piece |
More photos please contact Sansion Power Electric
Features:
√ Integrated with calibrator, load box, regulator, easy to connection.
√ Secondary current to be switched by rotary.
√ External regulator and current injection could be connected to increase or adjust capacity easily.
√ Protective circuit, reliable and safe.
√ Under CT/PT measuring, the impedance of secondary circuit or the active component and idle component of admittance could be measured at any time.
√ Polarity could be indicated automatically, and auto break differential current/voltage circuit to insure the safety and alarming by sound light.
√ To be used as rectangular coordinate system AC potentiometer, to measure the AC low current or low voltage.
√ To be used with isolating PT and control unit to measure the secondary drop voltage of PT.
√ The reference CT/PT or two stage CT/PT or Inductive Divider all could be used as standard reference during measuring.
√ LCD screen, English interface.
√ 40 groups CT storage, the 1% error results also can be stored.
√ PC and corresponding software could be connected to operate.
√ Build-in printer.
Partial Specifications:
1. CT/PT Analyzer
√ Temperature: 5ºC--40ºC RH:<80%(25ºC) Altitude:<2500m
√ Supply frequency:50Hz±0.5 Hz Supply voltage:220V±5V
√ Measuring range:
Cophase component(%): 0.0001~200.0 Resolution:0.0001
Flash component:0.001~700.0 Resolution:0.001
Impedance(Ω): 0.0001~20.0 Resolution:0.0001
Admittance(ms): 0.0001~20.0 Resolution:0.0001
√ Intrinsic error:
Cophase component:ΔX=±(X×2%+Y×2%±Dx)(one degree is optional)
Quadrature component:ΔY=±(X×2%+Y×2%±Dy)(one degree is optional)
"X","Y"--Displayed value
"Dx,Dy"--Displayed value
"Dx, Dy" quantization error
Dx=2, Dy=5
Dial indicator: 1.0 degree
2. PT Load Box
√ Working condition:
Temperature: 5-40ºC
Relative Humidity: <80%(25ºC)
Altitude: <1500m
√ Rated capacity:1.25~158.75VA
√ Voltage range:20%-120%
√ Secondary voltage: 100V
√ Power factor:0.8 ,1.0
√ Accuracy:±3%±0.01VA
√ Testing voltage:2kV
√ Rated frequency:50Hz
3. CT Load Box
√ Working Condition:
Temperature:5-40ºC Humidity:<80%(25ºC)
Altitude: <1500m Supply frequency:50Hz
√ Rated capacity:80VA (O-3.2Ω)
√ Measuring range:5%-120%
√ Secondary current: 5A
√ Power factor:0.8, 1
√ Accuracy: ±3%±0.0025VA
√ Testing voltage:2KV
4. Self Current Injection CT
5. Self Boosting PT
6. Self Boosting PT
7. Dual Regulating Controller
8. Large Current Leads
The max. output capacity should be well matched with booster (current injector), so that the output of regulator can be ensured 10% more than measuring range.
1000A *3m * 1
500A * 3m * 2
250A * 3m * 2
100A *3m * 2
9. Secondary Current/Voltage Cable
10. 10 CT/PT Calibrating Software
Please contact us for further information.
Warranty: One year quality guarantee after shipment.
More information, please kindly contact with us, we can customize the suitable test set according your requirements and give you the best quotation. Thank you!
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2005
Total Annual:
1000000-1000000
Employee Number:
100~200
Ecer Certification:
Active Member
Sansion Power Electric was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, w... Sansion Power Electric was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, w...
Get in touch with us
Leave a Message, we will call you back quickly!