| Payment Terms | T/T, L/C |
| Supply Ability | 1000/Month |
| Delivery Time | 15-20 DAYS |
| Packaging Details | Standard export packaging |
| Total Capacity | 30KW-100kw |
| Fan Section | Centrifugal EC FAN |
| Air Flow(㎡/h) | 9200-27000 |
| Air Fiter | G4 |
| Compressor | Scroll Compressors |
| Refrigerant | R410A |
| Humidifier Inlet Pipe(in) | G1/2" |
| Condensate Drainage DN(mm) | 18 |
| Brand Name | Coolent |
| Model Number | CYA |
| Certification | ISO/CE |
| Place of Origin | China |
View Detail Information
Explore similar products
Experience the Benefits of Our Precision Air Conditioning Units OpenResty Server
Floor Standing Data Center Precision Air Conditioner 100KW With High Dual-Fan
IDC Cooling System Precision Air Conditioning Units
70KW Precision Air Conditioning System , Precision Air Conditioning For Data
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 1000/Month |
| Delivery Time | 15-20 DAYS | Packaging Details | Standard export packaging |
| Total Capacity | 30KW-100kw | Fan Section | Centrifugal EC FAN |
| Air Flow(㎡/h) | 9200-27000 | Air Fiter | G4 |
| Compressor | Scroll Compressors | Refrigerant | R410A |
| Humidifier Inlet Pipe(in) | G1/2" | Condensate Drainage DN(mm) | 18 |
| Brand Name | Coolent | Model Number | CYA |
| Certification | ISO/CE | Place of Origin | China |
| High Light | Intelligent Dual Cycle Precision Air Conditioning ,Dual Cycle Refrigerant Precision Air Conditioning | ||
Product Description
| Coolnet fluorine pump series dual-cycle refrigerant system is a high-efficiency and energy-saving precision air conditioner. It provides precise temperature and humidity control for large and medium-sized data rooms.Dual cycle system makes full use of outdoor natural cold sources and uses a set of refrigeration systems to achieve three refrigeration modes, It adopts high-efficiency compressor and EC centrifugal fan to meet the requirements of 24X7 all-weather continuous operation. |
|
Advantages
| Natural Cooling Mode of Fluorine Pump
component operates independently of the pump, The gaseous refrigerant completely condenses into liquid in the natural cooling coil, significantly reducing the energy consumption of the unit on of the unit is significantly reduced
Mixed Refrigeration Mode
component and compressor operate together, resulting in a significant improvement in overall energy efficiency
Compressor Refrigeration Mode
cooling requirements of the computer room.
|
Factory View
![]()
Product Packaging
![]()
.
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
10,000,000.00-10,000,000.00
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container-qwe789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; } .gtr-container-qwe789 p { font-size: 14px; margin-bottom: 1em; text-align: left !important; word-break: normal; ... .gtr-container-qwe789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; } .gtr-container-qwe789 p { font-size: 14px; margin-bottom: 1em; text-align: left !important; word-break: normal; ...