| Payment Terms | T/T |
| Supply Ability | 1000/Month |
| Delivery Time | 4W |
| Packaging Details | WOODEN |
| cooling capacity | 55KW |
| Mounting | Floor Standing |
| Type | precision air conditioning unit(chilled water) 3ton 5ton 10ton |
| After-sales service provided | Engineers available to service machinery overseas |
| Warranty | 1 Year |
| Product name | Data Center Cooling Unit |
| Refrigerant | R22(R407C/R410A) |
| Application | Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity |
| Color | Black/Grey white/other custom colors |
| Power | 3N-380V-50Hz,220v/50hz/60hz |
| Airflow | Down Flow |
| Brand Name | Coolent |
| Model Number | CYAT40D/U |
| Certification | ISO/CE |
| Place of Origin | China |
View Detail Information
Explore similar products
Advanced Precision Climate Control PAC Unit for Data Centers with High
100KW Floor Standing Data Center Precision Air Conditioner with High Dual-Fan
26kW-120kW Cooling Capacity Precision Air Conditioning Unit with Floor Standing
70KW Floor Standing Precision Air Conditioning System with R407C Refrigerant for
Product Specification
| Payment Terms | T/T | Supply Ability | 1000/Month |
| Delivery Time | 4W | Packaging Details | WOODEN |
| cooling capacity | 55KW | Mounting | Floor Standing |
| Type | precision air conditioning unit(chilled water) 3ton 5ton 10ton | After-sales service provided | Engineers available to service machinery overseas |
| Warranty | 1 Year | Product name | Data Center Cooling Unit |
| Refrigerant | R22(R407C/R410A) | Application | Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity |
| Color | Black/Grey white/other custom colors | Power | 3N-380V-50Hz,220v/50hz/60hz |
| Airflow | Down Flow | Brand Name | Coolent |
| Model Number | CYAT40D/U | Certification | ISO/CE |
| Place of Origin | China | ||
| High Light | Liebert computer room air conditioning unit ,CRAC computer room air conditioning unit ,CCU CRAC air conditioning | ||
Liebert Close Control Unit Computer Room Cooling System 40KW
|
Products Introduction 1.Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer equipment. 2.Unlike comfort air conditioning, close control systems must operate constantly 24/7 requiring high reliability and minimal power consumption. 3.Quiet, compact and energy efficient equipment that can be configured to needed requirements. CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.
Feature & Benefits
|
Air Supply Method
![]()
Scope of Applications
|
Computer room and data center Switch room and mobile center station in telecommunication High-tech environment and lab Industrial automation control room and precision manufacturing workshop Standard test room and calibration center UPS and battery room Test room in hospital Biochemical culture chamber |
Technical Parameters
| Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
| Power Supply | 380V 3Ph-50HZ | |||||||||||||
| Air Discharge | Upflow/Downflow | |||||||||||||
| Cooling Capacity :24℃/50%RH | ||||||||||||||
| Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
| Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
| AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
| Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
| Compressor Hermetic scroll | ||||||||||||||
| Refrigerant | R407C | |||||||||||||
| Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
| Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
| Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
| Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
| Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
| Material | PTC | |||||||||||||
| Humidifier Section Electrode type | ||||||||||||||
| Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
| Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 | |
Certificates
![]()
Factory Details
![]()
Packing & Delivery
![]()
Case
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
10,000,000.00-10,000,000.00
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in ... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in ...
Get in touch with us
Leave a Message, we will call you back quickly!