China factories

China factory - Hefei Coolnet power  Co., ltd

Hefei Coolnet power Co., ltd

  • China,Hefei ,Anhui
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 10 Inch Integrated Monitor Rack Data Center For Financial Outlets
China 10 Inch Integrated Monitor Rack Data Center For Financial Outlets

  1. China 10 Inch Integrated Monitor Rack Data Center For Financial Outlets
  2. China 10 Inch Integrated Monitor Rack Data Center For Financial Outlets
  3. China 10 Inch Integrated Monitor Rack Data Center For Financial Outlets

10 Inch Integrated Monitor Rack Data Center For Financial Outlets

  1. MOQ: 1PCS
  2. Price: USD3000-10000/PCS
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 200 SETS PER MONTH
Delivery Time 20-35Working days
Packaging Details Standard export package
Name Cabinet System of micro data centers
Application Network closets/ Telecom sites/ Edge Computing
Voltage 380v/220v,110-220v/50-60Hz,220V/50Hz
Cabinet Quatities Single cabinet/ multiple cabinets optional
Operating voltage 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
Cabinet type 26U 42U 65U
Brand Name COOLNET
Model Number EC 20 ER 02 EC 12
Certification CE ISO
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 200 SETS PER MONTH
Delivery Time 20-35Working days Packaging Details Standard export package
Name Cabinet System of micro data centers Application Network closets/ Telecom sites/ Edge Computing
Voltage 380v/220v,110-220v/50-60Hz,220V/50Hz Cabinet Quatities Single cabinet/ multiple cabinets optional
Operating voltage 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V Cabinet type 26U 42U 65U
Brand Name COOLNET Model Number EC 20 ER 02 EC 12
Certification CE ISO Place of Origin CHINA
High Light 65U Rack Data CenterFinancial Outlets Rack Data Center65U Cabinet Micro Data Centers

10 Inch Integrated Monitor And Display Unit Rack Data Center For Financial Outlets

 

Procudt Introduction                                               

With the advent of the era of big data, industries such as cloud computing, mobile Internet, and the Internet of Things(IoT) are booming. The scale of data centers continues to expand, showing a trend of polarization. Eventually there are more and more micro data centers. Relying on its rich experience in data centers, Coolnetpower has launched a cabinet-level micro data center solution that integrates UPS power supply and distribution, cooling, cabinets, wiring, monitoring, and fire protection systems. Provide safe, reliable and efficient operation support for IT equipment, and realize one-stop deployment and unified operation and maintenance management of data room.

 

 

 

Features&Adavantages                                                     

1.The reliable UPS power supply and distribution system continuously escorts IT equipment, and can also customize a highly reliable system architecture that meets the national standard A and B standards to meet the availability requirements of different users.


2.Equipped with emergency ventilation device, when the air conditioner fails, natural ventilation can be turned on to provide time for users to back up; it can also be linked with the fire fighting system to make fire extinguishing gas smoothly enter the cabinet.

 

3.The dynamic environment monitoring system monitors comprehensive product operation data, provides alarms and various reports, realizes unattended, remote operation and maintenance; it can also be integrated into the upper management system for centralized management;

 

4.Save construction time: integrated products, on-site installation time is completed within one day, and the construction period is greatly shortened when large-scale deployment.


5.High-efficiency and energy-saving: high-frequency UPS, the efficiency of the whole machine reaches 92%; cabinet-level refrigeration + fully enclosed hot and cold aisle refrigeration, which saves more than 30% energy than the traditional cooling method, and the PUE of the whole machine can be lower than 1.45.

 

 

Technical Parameter                                                         

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 

Application                                                                      

Suitable for small and medium-sized computer rooms; the central computer room of the convergence layer that requires monitoring and management, cabinet cascading, modular construction, and phased deployment.

1. Financial outlets, government, education, medical, military, transportation, small and medium-sized enterprises, supermarkets and retail, etc.

2. No special small computer room is required (less than 50 square meters, or the width is not enough for the computer room)

3. Mainly for load: a small number of core equipment such as servers, switches, gateways and firewalls.

4. Main application areas: construction of small and micro computer rooms, transformation of simple computer rooms, computer rooms of various branches, public security law, universities, hospitals, enterprises, hospitals, city and county business centers (finance, three major operators, etc.).

Certification                                                                       

 

Case                                                                                 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    10,000,000.00-10,000,000.00

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

  Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall s...   Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall s...

+ Read More

Get in touch with us

  • Reach Us
  • Hefei Coolnet power Co., ltd
  • Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
  • Janet Si
  • +86 18326091011
  • https://www.precisionacunits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement