China Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner
China Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner

  1. China Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner
  2. China Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner
  3. China Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner

Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner

  1. MOQ: 1pcs
  2. Price: USD3000-10000/pcs
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 200 SETS PER MONTH
Delivery Time 20-35 days
Packaging Details Standard export package
Application Network Closets/ Telecom Sites /Edge Computing/Smart City
Cabinet Multiple Cabinets/Single Cabinet
Cooling Rack Mounted PAC Units
Operating 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
Brand Name Coolnet
Model Number Mirco data center
Certification CE ISO
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 200 SETS PER MONTH
Delivery Time 20-35 days Packaging Details Standard export package
Application Network Closets/ Telecom Sites /Edge Computing/Smart City Cabinet Multiple Cabinets/Single Cabinet
Cooling Rack Mounted PAC Units Operating 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
Brand Name Coolnet Model Number Mirco data center
Certification CE ISO Place of Origin China
High Light Rack Mounted PAC Micro Data CenterMicro Rack Data Center42U Cabinet Data Center

Cabinet Data Center Micro Data Center With Rack Mounted Precision Air Conditioner

 

Product Introduction                                                           

Coolnet Cabinet Data Center is an integrated cabinet which contains cooling system, power system, monitoring system and rack system, etc.. There are more and more micro data centers, and it has been facing the dilemma that it is difficult to unify the planning, construction and operation management. The integrated cabinet deeply integrates data center infrastructure products, including multiple subsystems such as UPS, power distribution, refrigeration, cabinets, and fire protection, and implements overall management of the entire system through the monitoring system.

 

Advantages                                                                          

1. More precise. In-depth integration of UPS integrated cabinet products, and factory pre-verification tests are more standardized, safe and reliable than on-site construction; the fully sealed design eliminates the harm of external air dust and corrosive gases to IT equipment; the dynamic environment monitoring system is fully Monitor infrastructure in all directions, alert abnormal conditions in time, and be safe and secure.


2. More time-saving. The productized design allows the IC series cabinet-type smart data center to complete the installation and delivery within one day on site, which is more than 2 times faster than the traditional construction mode.


3. Lower space. The Coolent integrated cabinet data center design saves more than 40% of the floor space compared to the traditional computer room and saves supporting investment: fully enclosed design, can be installed in various environments (computer room, utility room, aisle, etc.), without the need for special investment in computer room construction and supporting facilities Save construction time.

 

Feature                                                                                    

 

Cooling System

 

Adopting international advanced components and self-developed precision control system, it has been successfully used in a large number of data centers and integrated cabinets. The cooling capacity is 7KW-12KW, and it can operate for 7*24*365 hours in order to provide a stable working environment for the equipment.

 

UPS System

 

As a public power grid, the mains system is connected to thousands of various loads, some of which are larger inductive, capacitive, switching power supplies and other loads, not only obtain power from the grid, but also have an impact on the grid in turn Deteriorating the quality of the grid. The UPS integrated in the cabinet can provide a stable power supply, which is enough to ensure the stable operation of the server.

 

Rack System

 

Using visual monitoring and display, the main interface is the overall information display, and the detailed information of each subsystem is also viewed, making it easier for managers to obtain equipment information.

 

 

Technical Parameter                                                                

 

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 

Factory View                                                                                 

 

Case                                                                                     

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    10,000,000.00-10,000,000.00

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th...

+ Read More

Get in touch with us

  • Reach Us
  • Hefei Coolnet power Co., ltd
  • Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
  • https://www.precisionacunits.com/