Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
| Payment Terms | T/T |
| Delivery Time | 1week |
| Wireless Compatibility | Fluke Connect® |
| Current Clamp Range | 1A AC to 400 A AC |
| Recording Function | Min/Max/Average |
| Wiring Verification | Identifies common wiring problems |
| Application | Industrial, HVAC, Automotive, Oil & Gas |
| Gfci Test | Integrated |
| Insulation Test Range | 0.01 MΩ to 2.0 GΩ |
| Included Unit | PRV240 Proving Unit |
| Brand Name | FLUKE |
| Model Number | Fluke 15B+ Digital Multimeter |
| Place of Origin | usa |
View Detail Information
Explore similar products
Fluke 15B MAX & 17B MAX Digital Multimeter
Fluke 117 Electrician's Multimeter with Non-Contact Voltage
Fluke 283 FC CAT III 1500V Digital Multimeter
Fluke 87V MAX True-rms Digital Multimeter
Product Specification
| Payment Terms | T/T | Delivery Time | 1week |
| Wireless Compatibility | Fluke Connect® | Current Clamp Range | 1A AC to 400 A AC |
| Recording Function | Min/Max/Average | Wiring Verification | Identifies common wiring problems |
| Application | Industrial, HVAC, Automotive, Oil & Gas | Gfci Test | Integrated |
| Insulation Test Range | 0.01 MΩ to 2.0 GΩ | Included Unit | PRV240 Proving Unit |
| Brand Name | FLUKE | Model Number | Fluke 15B+ Digital Multimeter |
| Place of Origin | usa | ||
| High Light | Fluke 15B+ digital multimeter ,Fluke 15B+ electrical tester ,digital multimeter with warranty | ||
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
| Function | Range | Resolution | Accuracy | |
|---|---|---|---|---|
| AC volts (40 Hz to 500Hz)1 |
4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0% + 3 | |
| DC volts | 4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5% + 3 | |
| AC millivolts | 400.0 mV | 0.1 mV | 3.0% + 3 | |
| DC millivolts | 400.0 mV | 0.1 mV | 1.0% + 10 | |
| Diode test2 | 2.000 V | 0.001 V | 10% | |
| Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 |
|
| Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 |
|
| AC current μA (40 Hz to 400 Hz) |
400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5% + 3 | |
| AC current mA (40 Hz to 400 Hz) |
40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 | |
| AC current A (40 Hz to 400 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 | |
| DC current μA | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5% + 3 | |
| DC current mA | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 | |
| DC current A | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 | |
| Backlight | Yes | |||
| 1AC volts are specified from 1% to 100% of range. Inputs below 1% of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). |
||||
| Function | Overload protection | Input impedance (Nominal) | Common mode rejection ratio | Normal mode rejection ratio |
|---|---|---|---|---|
| AC volts | 1000 V 1 | >10 MΩ <100 pF | >60 dB at dc, 50 Hz or 60 Hz |
- |
| AC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
| DC volts | 1000 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
| DC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
| 1 106 V Hz Max | ||||
| General specifications | |
|---|---|
| Maximum voltage between any terminal and earth ground | 1000 V |
| Display (LCD) | 4000 counts, updates 3/sec |
| Battery type | 2 AA, NEDA 15A, IEC LR6 |
| Battery life | 500 hours minimum |
| Temperature | |
| Operating | 0 °C to 40 °C |
| Storage | -30 °C to 60 °C |
| Relative humidity | |
| Operating humidity | Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C; ≤75% RH at 30 °C to 40 °C |
| 40 MΩ range ≤80% RH at 10 °C to 30 °C; ≤70% RH at 30 °C to 40 °C |
|
| Altitude | |
| Operating | 2000 m |
| Storage | 12,000 m |
| Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
| Fuse protection for current inputs | 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only. |
| Size (H x W x L) | 183 x 91 x 49.5 mm |
| Weight | 455 g |
| IP rating | IP 40 |
| Safety | IEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2 |
| Electromagnetic Compatibility | IEC 61326-1: Portable EMC Environment |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Shaanxi Qindiyuan Environmental Equipment Co., Ltd., established in 2018, is a national high-tech enterprise integrating independent research and development, production, sales, and technical services for industrial instruments and meters as well as explosion-proof inspection robots. We not only... Shaanxi Qindiyuan Environmental Equipment Co., Ltd., established in 2018, is a national high-tech enterprise integrating independent research and development, production, sales, and technical services for industrial instruments and meters as well as explosion-proof inspection robots. We not only...