Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
| Payment Terms | T/T |
| Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days |
| Connection type | 1/4 inch NPT |
| Application | Industrial process control, HVAC, Hydraulic systems |
| Outputsignal | 4-20 mA |
| Material | Stainless Steel |
| Measurementrange | 0 to 1000 psi |
| Responsetime | ≤ 1 second |
| Protectionrating | IP65 |
| Operatingtemperature | -20°C to 80°C |
| Pressuretype | Gauge, Absolute, Differential |
| Productname | Pressure Measurement Instruments |
| Calibration | Factory calibrated |
| Displaytype | Digital LCD |
| Powersupply | 24 V DC |
| Accuracy | ±0.5% |
| Mountingoptions | Panel mount, Wall mount |
| Brand Name | PR |
| Model Number | PR 4116 |
| Certification | CO |
| Place of Origin | Denmark |
View Detail Information
Explore similar products
PR 4131 Universal Trip Amplifier FM Approved 2 Relay Outputs 2 Adjustable Alarm
Universal Trip Amplifier PR 4179B Output 2 Relays Programming Process Monitoring
PR 5115A Signal Calculator Input For RTD Ohm TC MV MA Signals
AC DC Universal Signal Transmitter PR 4179 Outputs Passive / Active Current
Product Specification
| Payment Terms | T/T | Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days | Connection type | 1/4 inch NPT |
| Application | Industrial process control, HVAC, Hydraulic systems | Outputsignal | 4-20 mA |
| Material | Stainless Steel | Measurementrange | 0 to 1000 psi |
| Responsetime | ≤ 1 second | Protectionrating | IP65 |
| Operatingtemperature | -20°C to 80°C | Pressuretype | Gauge, Absolute, Differential |
| Productname | Pressure Measurement Instruments | Calibration | Factory calibrated |
| Displaytype | Digital LCD | Powersupply | 24 V DC |
| Accuracy | ±0.5% | Mountingoptions | Panel mount, Wall mount |
| Brand Name | PR | Model Number | PR 4116 |
| Certification | CO | Place of Origin | Denmark |
| High Light | PR 4116 Universal Transmitter ,Universal Transmitter 4-20mA ,Universal Transmitter PR 4116 | ||
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-condensing) |
| Protection degree | IP20 |
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) with PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 175 g |
| Weight incl. 4501 / 451x (approx.) | 190 g / 205 g |
| Wire size | 0.13...2.08 mm² AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 2...13.2 Hz: ±1 mm 13.2...100 Hz: ±0.7 g |
| Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
| Fuse | 400 mA SB / 250 VAC |
| Max. required power | ≤ 2.5 W |
| Max. power dissipation | ≤ 2.5 W |
| Test voltage | 2.3 kVAC |
| Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
| Temperature input (0...90%, 100...10%) | ≤ 1 s |
| mA / V input (0...90%, 100...10%) | ≤ 400 ms |
| Signal dynamics, input | 24 bit |
| Signal dynamics, output | 16 bit |
| Signal / noise ratio | Min. 60 dB (0...100 kHz) |
| Accuracy | Better than 0.1% of selected range |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
| RTD type | Pt10/20/50/100/200/250; Pt300/400/500/1000; Ni50/100/120/1000; Cu10/20/50/100 |
| Cable resistance per wire | 50 Ω (max.) |
| Sensor current | Nom. 0.2 mA |
| Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
| Sensor error detection | Yes |
| Short circuit detection | < 15 Ω |
| Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
| Cold junction compensation (CJC) via external sensor in 5910 | 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C |
| CJC via internal mounted sensor | ±(2.0°C + 0.4°C * Δt) |
| Sensor error detection | Yes |
| Current input measurement range | 0...23 mA |
| Programmable current ranges | 0...20 and 4...20 mA |
| Voltage input measurement range | 0...12 VDC |
| Programmable voltage ranges | 0/0.2...1, 0/1...5, 0/2...10 VDC |
| Signal range | 0...23 mA |
| Programmable signal ranges | 0...20/4...20/20...0/20...4 mA |
| Load (@ current output) | ≤ 800 Ω |
| Output limitation | 3.8...20.5 mA (4...20 and 20...4 mA signals) 0...20.5 mA (0...20 and 20...0 mA signals) |
| Relay functions | Setpoint, Window, Sensor error, Latch, Power and Off |
| Max. voltage | 250 VAC / VDC |
| Max. current | 2 A |
| Max. AC power | 500 VA |
| c UL us, UL 508 | E231911 |
| FM | 3025177 |
| DNV Marine | TAA0000101 |
| EU RO MR Type Approval | MRA000000Z |
| SIL | Hardware assessed for use in SIL applications |
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
| EAC LVD | TR-CU 004/2011 |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
.gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;... .gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;...
Get in touch with us
Leave a Message, we will call you back quickly!