China factories

Chat Now Send Email
China factory - Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.

Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.

  • China,Xianyang ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work
China HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work

  1. China HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work
  2. China HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work
  3. China HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work
  4. China HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work

HIOKI Ground Resistance Tester FT6041 Strong On-site Adaptability High Work

  1. MOQ: 1
  2. Price: 3475-4360USD
  3. Get Latest Price
Payment Terms T/T
Supply Ability 99pcs/6-8weeks
Delivery Time 6-8weeks
Packaging Details Standard cardboard box packaging
Operatingtemperature -40°C to 85°C
Calibration Factory calibrated
Measurementrange 0 to 1000 psi
Displaytype LCD, Analog Dial
Pressurerange 0 to 10000 psi
Applications Industrial, HVAC, Automotive, Oil & Gas
Responsetime ≤ 1 ms
Ingressprotection IP65
Powersupply 24 V DC
Accuracy ±0.25% of full scale
Protectionrating IP65, IP67
Mounting Panel mount or pipe mount
Brand Name HIOKI
Model Number HIOKI Ground resistance tester FT6041
Certification CO
Place of Origin Japan

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 99pcs/6-8weeks
Delivery Time 6-8weeks Packaging Details Standard cardboard box packaging
Operatingtemperature -40°C to 85°C Calibration Factory calibrated
Measurementrange 0 to 1000 psi Displaytype LCD, Analog Dial
Pressurerange 0 to 10000 psi Applications Industrial, HVAC, Automotive, Oil & Gas
Responsetime ≤ 1 ms Ingressprotection IP65
Powersupply 24 V DC Accuracy ±0.25% of full scale
Protectionrating IP65, IP67 Mounting Panel mount or pipe mount
Brand Name HIOKI Model Number HIOKI Ground resistance tester FT6041
Certification CO Place of Origin Japan
High Light HIOKI ground resistance tester with warrantydigital multimeter with six measurement functionsground resistance tester for on-site adaptability
  • Supports 4-electrode method, offering rich measurement functions
  • MEC function, can measure without cutting off the grounding electrode
  • Dustproof and waterproof IP67, operating temperature -25°C ~ 65°C, drop-resistant
  • No need to insert auxiliary grounding rods when using grounding network components
  • Shortens operation time, measurement time is only 6 seconds, and test line setup and storage are also easy
  • Whether in narrow spaces or on measuring busbars, the current clamp can be easily clamped (optional)
  • Supports wireless communication, allowing measurement data to be sent to a smartphone or tablet (when installing optional Z3210)
  • Measurement can be done using a clamp sensor (FT6041-91 kit includes 2 clamp sensors)
Basic Parameters (Accuracy Guarantee Period: 1 year)

*1: -25°C–40°C (80% RH or lower), 40°C–45°C (60% RH or lower), 45°C–50°C (50% RH or lower), 50°C to 55°C (40% RH or lower), 55°C to 60°C (30% RH or lower), 60°C to 65°C (25% RH or lower)

※2: When using four AA nickel-metal hydride rechargeable batteries (reference value at 23°C)

Measurement items Ground resistance measurement (4-electrode method, 3-electrode method, 2-electrode method, MEC function, clamp type), low-resistance measurement (4-terminal method, 2-terminal method), ground voltage measurement, earth resistivity
Ground voltage measurement 0–30.0 Vrms, accuracy: ± 2.3% rdg ±8 dgt (50/60 Hz), ± 1.3% rdg ±4 dgt (DC)
Function Live warning display, automatic power saving, earth resistivity display (4-electrode method only), zero adjustment, auto hold, continuous measurement, wireless communication (when installing Z3210), buzzer, comparator, display switching, ground overvoltage display (low resistance measurement)
Operating temperature range -25°C to 65°C, ※1 (no condensation)
Temperature and humidity range -25°C to 65°C, below 80% RH (no condensation)
Dustproof and waterproof IP65, IP67(IEC 60529, EN 60529)
Applicable standards EN IEC 61010-2-030: 2021 (Safety), EN 61326 (EMC), EN 61557-1, EN 61557-10, EN 61557-4 (Low Resistance), EN 61557-5 (Ground Resistance Meter)
Power supply No. 5 nickel-metal hydride rechargeable batteries *4 or No. 5 alkaline batteries (LR6) *4
Measurement count (※2) 500 tests (3-electrode method, when Z3210 is not installed), 400 times (3-electrode method, when Z3210 is installed, during wireless communication)
Volume and weight Approx. 189W * 148H * 48D mm, approx. 765g (including battery and sheath)
Attachment Auxiliary grounding rod L9840 (2 pieces per set) *2, Test wire L9841 *1, Test wire L9845-31 *1, Test wire L9845-33 *1, Test wire L9845-52 *1, Grounding grid assembly L9846 *2, Test wire L9787 *1, Carrying box C0208 *1, Carrying box C0209 *1, No. 5 alkaline battery (LR6) *4, User manual *1
Grounding resistance measurement (4-electrode method, 3-electrode method, 2-electrode method)
Operating methods Applied voltage, voltage, and current measurement (effective resistance measured by synchronous detection).
Measurement range 3 Ω (0〜3.000 Ω) 30 Ω (0〜30.00 Ω) 300 Ω (30.0Ω〜300.0 Ω) 300 Ω and 3 k Ω (300Ω to 3000 Ω) 3k Ω to 30k Ω (3.00 k Ω to 30.00 k Ω) 30 k Ω up to 300 k Ω (30.0 k Ω to 300.0 k Ω)
Accuracy Not specified ±1.5% rdg ±6 dg ±1.5% rdg ±4 dgt
The allowable resistance of the auxiliary grounding electrode 5 kΩ 50 kΩ 100 kΩ
Allowed ground voltage 30 V rms or 42.4 V peak
MEC function (4-electrode method + clamp meter, 3-electrode method + clamp meter)
Measurement methods Applied voltage, voltage, and current measurement (effective resistance measured through synchronous detection)
Measurement range 30 Ω (0.00Ω〜30.00 Ω) 300 Ω (30.0Ω〜300.0 Ω) 3000 Ω (300Ω〜3000 Ω) 30.00 k Ω (3 k Ω〜30.00 k Ω)
Accuracy ±5% rdg ±6 dgt ±5% rdg ±3 dgt
Ground resistance measurement (clamp type)
Measurement methods Applied voltage, voltage, and current measurement (effective resistance measured through synchronous detection)
Measurement range 20 Ω (0.02Ω〜20.00 Ω) 200 Ω (20.0Ω〜200.0 Ω) 500 Ω (200Ω〜500 Ω)
Accuracy ±7% rdg ±3 dgt ±35% rdg
Low resistance measurement
Open-circuit voltage 4.0 V〜6.9 V
Measuring current Above 200 mA
Measurement range 30 Ω (0.00Ω〜30.00 Ω) 300 Ω (30.0Ω〜300.0 Ω) 3000 Ω (300Ω〜3000 Ω)
Accuracy ±3 dgt (0.00Ω〜0.19 Ω) ±2% rdg ±2 dgt (0.20Ω〜10.00 Ω) ±2% rdg ±2 dgt

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    5000000-10000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Shaanxi Qindiyuan Environmental Equipment Co., Ltd., established in 2018, is a national high-tech enterprise integrating independent research and development, production, sales, and technical services for industrial instruments and meters as well as explosion-proof inspection robots. We not only... Shaanxi Qindiyuan Environmental Equipment Co., Ltd., established in 2018, is a national high-tech enterprise integrating independent research and development, production, sales, and technical services for industrial instruments and meters as well as explosion-proof inspection robots. We not only...

+ Read More

Get in touch with us

  • Reach Us
  • Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
  • F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
  • https://www.pressure-instruments.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement