Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
| Payment Terms | T/T |
| Supply Ability | 99pcs/6-8weeks |
| Delivery Time | 6-8weeks |
| Packaging Details | Standard cardboard box packaging |
| Powersupply | 24 V DC |
| Mountingtype | Panel, Wall, Pipe |
| Protectionrating | IP65 |
| Mounting | Panel mount or pipe mount |
| Outputsignal | 4-20 mA, 0-10 V |
| Displaytype | Digital LCD |
| Applications | Industrial, Automotive, HVAC, Oil & Gas |
| Measurementtype | Gauge, Absolute, Differential |
| Responsetime | ≤ 1 ms |
| Accuracy | ±0.25% FS |
| Ingressprotection | IP65, IP67 |
| Calibration | Factory calibrated |
| Application | Industrial, HVAC, Automotive |
| Connectiontype | 1/4 inch NPT |
| Operatingtemperature | -20°C to 85°C |
| Brand Name | HIOKI |
| Model Number | HIOKI Digital multimeters DT4281 and DT4282 |
| Certification | CO |
| Place of Origin | Japan |
View Detail Information
Explore similar products
Fluke 15B MAX & 17B MAX Digital Multimeter
Fluke 117 Electrician's Multimeter with Non-Contact Voltage
Fluke 283 FC CAT III 1500V Digital Multimeter
Fluke 87V MAX True-rms Digital Multimeter
Product Specification
| Payment Terms | T/T | Supply Ability | 99pcs/6-8weeks |
| Delivery Time | 6-8weeks | Packaging Details | Standard cardboard box packaging |
| Powersupply | 24 V DC | Mountingtype | Panel, Wall, Pipe |
| Protectionrating | IP65 | Mounting | Panel mount or pipe mount |
| Outputsignal | 4-20 mA, 0-10 V | Displaytype | Digital LCD |
| Applications | Industrial, Automotive, HVAC, Oil & Gas | Measurementtype | Gauge, Absolute, Differential |
| Responsetime | ≤ 1 ms | Accuracy | ±0.25% FS |
| Ingressprotection | IP65, IP67 | Calibration | Factory calibrated |
| Application | Industrial, HVAC, Automotive | Connectiontype | 1/4 inch NPT |
| Operatingtemperature | -20°C to 85°C | Brand Name | HIOKI |
| Model Number | HIOKI Digital multimeters DT4281 and DT4282 | Certification | CO |
| Place of Origin | Japan | ||
| High Light | HIOKI digital multimeter high precision ,DT4282 multimeter high-speed response ,professional DMM testing equipment | ||
| DT4281 | DT4282 | |
|---|---|---|
| DC voltage | 60.000 mV~1000.0 V, 6 ranges, basic accuracy: ±0.025% rdg. ±2 dgt. | |
| AC voltage: 45~66Hz |
60.000 mV~1000.0 V, 6 ranges, frequency response: 20 Hz~100 kHz | |
| Basic accuracy: ±0.3% rdg. ± 25 dgt. (RMS value, crest factor below 3) | ||
| DC + AC voltage: 45~66Hz |
6. 0000 V~1000.0 V, 4 ranges, frequency response: 20 Hz~100 kHz | |
| Basic accuracy: ±0.4% rdg. ±30 dgt. (RMS value, crest factor below 3) | ||
| Resistance | 60.000 Ω~600.0 MΩ, 8 range ranges, [600.00 nS, DT4282 only] | |
| Basic accuracy: ±0.03% rdg. ±2 dgt. | ||
| Direct current | 600.00 μA~600.00 mA, 4 ranges | 600.00 μA~10.000 A, 6 ranges |
| Basic accuracy: ±0.05% rdg. ±5 dgt. | ||
| AC current: 45~66Hz |
600.00 μA~600.00 mA, 4 ranges | 600.00 μA~10.000 A, 6 ranges |
| Basic accuracy: ±0.6% rdg. ±5 dgt. (RMS value, crest factor below 3) | ||
| Frequency Response: 20 Hz~20 kHz (at 600 μA~600 mA range) | ||
| AC current (measured by AC clamp probe) 40~1kHz |
10.00 A~1000 A, 7 range ranges | None |
| Basic accuracy: ±0.6% rdg. ±2 dgt. Plus the clamp probe for testing accuracy (RMS value, crest factor below 3) |
None | |
| Peak measurement | DC V measurement: signal width above 4ms (single pass), over 1ms (repeated) | |
| AC V, DC/AC A measurement, etc.: signal width over 1ms (single pass), 250μs or more (repeated) | ||
| Capacitive coupling | 1.000 nF~100.0 mF, 9 ranges, basic accuracy: ± 1.0% rdg. ±5 dgt. | |
| Continuity check | Conduction ON threshold: 20~500 Ω and below ; Conduction OFF threshold: 220~600 Ω or below; response time: over 5ms |
|
| Diode testing | Open-circuit voltage: below 4.5V, test current: below 1.2mA, clockwise threshold: 0.15~3V, 7 types | |
| Frequency | AC V, DC+AC V, AC A measurement, pulse width above 1μs (duty cycle 50%) 99.999 Hz (above 0.5 Hz) ~ 500.00 kHz, 5 ranges, ± 0.02% rdg. ±3 dgt. |
|
| Decibel conversion measurement | Standard impedance setting (dBm), 4 Ω~1200 Ω, 20 types. Displays the dB conversion value (dBV) of the standard value relative to AC voltage |
|
| Other features | Filtering function (removal of harmonic interference, limited to AC600V/1000V range), display value hold, auto hold, associated display, maximum/minimum value display, measurement value storage, USB communication (optional), percentage conversion display (4-20mA/0-20mA converted to 0~100%), backlight |
|
| Display | 5-digit LCD display, max. 60000 dgt. | |
| Displays the update rate | 5 times/s (Capacitive coupling: based on measurement values 0.05~2 times/s, temperature: 1 time/s) | |
| Power supply | No. 5 alkaline battery (LR6) *4, continuous usage time: 100 hours | |
| Volume and weight | 93W * 197H * 53D mm, 650g (including battery and test cable) | |
| Attachment |
Test line L9207-10※2*1, user manual * 1, AA alkaline battery (LR6) *4 ※2: Starting from March 2025, the L9300 will gradually replace the L9207-10. |
|
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Shaanxi Qindiyuan Environmental Equipment Co., Ltd., established in 2018, is a national high-tech enterprise integrating independent research and development, production, sales, and technical services for industrial instruments and meters as well as explosion-proof inspection robots. We not only... Shaanxi Qindiyuan Environmental Equipment Co., Ltd., established in 2018, is a national high-tech enterprise integrating independent research and development, production, sales, and technical services for industrial instruments and meters as well as explosion-proof inspection robots. We not only...
Get in touch with us
Leave a Message, we will call you back quickly!