Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
| Payment Terms | T/T |
| Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days |
| User Memory | 48 MB |
| Availability | In Stock |
| Hs Code | 85389091 |
| Thread | NPT |
| Load Resistance | 0 to 1,440 ohms |
| Storage Temperature | -40 to 70°C (-40 to 158°F) |
| Coo | Yes |
| Resolution | 12 bit x 12 bit |
| Product No | VE3006 |
| Housing Material | Aluminum or Stainless Steel |
| Supply Voltage | 10.8 to 42.4 Vdc at terminals |
| Actuator Type | Side Rotary - No Lever |
| Stage Design | stage design with dry torque Motor |
| Output | 4-20mADC/1-5VDC |
| Products Name | Differential Pressure Transmitter |
View Detail Information
Explore similar products
PR 3102 Pt100 converter 0.1% accuracy excellent EMC performance selectable
PR 3111 TC Converter Temperature Transmitter 0.05% Accuracy 6.1 mm Slimline
Pt100 converter isolated transmitter 0.05% accuracy 6.1 mm slimline housing
PR 3331 Temperature Converter Loop-Powered Transmitter 0.05% Accuracy 6.1mm
Product Specification
| Payment Terms | T/T | Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days | User Memory | 48 MB |
| Availability | In Stock | Hs Code | 85389091 |
| Thread | NPT | Load Resistance | 0 to 1,440 ohms |
| Storage Temperature | -40 to 70°C (-40 to 158°F) | Coo | Yes |
| Resolution | 12 bit x 12 bit | Product No | VE3006 |
| Housing Material | Aluminum or Stainless Steel | Supply Voltage | 10.8 to 42.4 Vdc at terminals |
| Actuator Type | Side Rotary - No Lever | Stage Design | stage design with dry torque Motor |
| Output | 4-20mADC/1-5VDC | Products Name | Differential Pressure Transmitter |
| High Light | HART 7 temperature transmitter with high accuracy ,isolated temperature converter slimline housing ,pre-calibrated temperature transmitter selectable response time | ||
| Operating temperature | -25°C to +70°C |
| Storage temperature | -40°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
| Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
| Dimensions (HxWxD) | 113 x 6.1 x 115 mm |
| Weight approx. | 70 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.5 mm² / AWG 26...12 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 2...25 Hz: ±1.6 mm 25...100 Hz: ±4 g |
| Supply voltage | 16.8...31.2 VDC |
| Max. required power | 0.70 W |
| Max. power dissipation | 0.70 W |
| Isolation voltage, test / working | 2.5 kVAC / 300 VAC (reinforced) |
| Zone 2 / Div. 2 | 250 VAC |
| Response time HART mode | 60 ms...60 s, programmable |
| Response time DIP mode | < 60 ms |
| Accuracy | Better than 0.05% of selected range |
| Signal / noise ratio | Min. 60 dB |
| Long-term stability | ±0.1% of span / year (±0.3% of span / 5 years) |
| Programming | DIP switches |
| Signal dynamics, input | 23 bit |
| Signal dynamics, output | 18 bit |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity | < ±1% of span |
| Incorrect DIP-switch setting identification | 3.5 mA output; LED 0.5 s / 1 Hz |
| Temperature range, Pt100 | -200...+850°C |
| Min. measurement range (span) | 10°C |
| Accuracy | Better than 0.05% of span or 0.1°C |
| Temperature coefficient | 0.02°C/°C or ≤ ±0.01%/°C |
| Sensor current | < 150 µA |
| Sensor cable resistance | < 50 Ω per wire |
| Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
| Sensor error detection | Yes - selectable via DIP-switch |
| Broken sensor detection | > 800 Ω |
| Shorted sensor detection | < 18 Ω |
| Temperature range, TC J | -100...+1200°C |
| Temperature range, TC K | -180...+1372°C |
| Min. measurement range (span) - TC J & K | 50°C |
| Accuracy | Better than 0.05% of span or 0.5°C |
| Temperature coefficient | 0.1°C/°C or ≤ ±0.01%/°C |
| Sensor cable resistance | < 5 kΩ per wire |
| Cold junction compensation (CJC): Accuracy @ external Pt100 input | Better than ±0.15°C |
| Cold junction compensation (CJC): Accuracy @ internal CJC | Better than ±2.5°C |
| Internal CJC error detection | Yes |
| External CJC error detection | Yes - selectable via DIP-switch |
| Open Thermocouple detection | Yes - selectable via DIP-switch |
| Signal range | 0...23 mA |
| Programmable signal ranges | 4...20 and 20...4 mA |
| Load (@ current output) | ≤ 600 Ω |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Sensor error indication | 3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF |
| Open output | < 20 V |
| HART protocol revisions | HART 7 |
| Updating time | 10 ms |
| ATEX | II 3 G Ex ec IIC T4 Gc |
| IECEx | Ex ec IIC T4 Gc |
| FM, US | Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4 |
| FM, CA | Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4 |
| EAC Ex | 2Ex nA IIC T4 Gc X |
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| ATEX | 2014/34/EU & UK SI 2016/1107 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
| EAC Ex | TR-CU 012/2011 |
| ATEX | KEMA 10ATEX0147 X |
| IECEx | KEM 10.0068X |
| UKEX | DEKRA 21UKEX0055X |
| c FM us | FM17US0004X / FM17CA0003X |
| c UL us, UL 61010-1 | E314307 |
| EAC Ex | EAEU KZ 7500361.01.01.08756 |
| DNV Marine | TAA00001RW |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
.gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;... .gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;...
Get in touch with us
Leave a Message, we will call you back quickly!