| Type | Testing Machine |
| Accuracy Class | High Accuracy |
| Accuracy | / |
| Application | PV Module Testing, Photovoltaic Panel Testing, Mechanical Load Testing, Solar PV Testing |
| customized support | OEM, ODM |
| power | 120V 5A |
| Protection Class | / |
| Voltage | 220 V |
| warranty | 1 Year |
| Cylinder Space | Cylinder space is adjustable |
| Cylinder Type | Low Friction |
| Cylinder Stroke | 400mm |
| Static Mechanical Load 1 | Downward pressure: 800 Pa ~ 12,000 Pa; |
| Static Mechanical Load 2 | Upward pull: 800 Pa ~ 6,000 Pa; |
| Dynamic Mechanical Load 1 | Downward pressure: -2,500 Pa ~ +2,500 Pa(Setting at software) |
| Dynamic Mechanical Load 2 | Cycle: 3~7 cycles/min |
| Brand Name | HAIDA |
| Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
PV Module Bypass Diode Dust Testing Chamber Machine (IP6X) Environmental Dust
Bypass Diode Water Immersion Tank For Precise Temperature Control And Safety
PV Potential Induced Degradation(PID) Testing Machine Photovoltaic Module Humid
Lab PV Salt Spray Tester Salt Spray Corrosion Testing Chamber Machine Photovolta
Product Specification
| Type | Testing Machine | Accuracy Class | High Accuracy |
| Accuracy | / | Application | PV Module Testing, Photovoltaic Panel Testing, Mechanical Load Testing, Solar PV Testing |
| customized support | OEM, ODM | power | 120V 5A |
| Protection Class | / | Voltage | 220 V |
| warranty | 1 Year | Cylinder Space | Cylinder space is adjustable |
| Cylinder Type | Low Friction | Cylinder Stroke | 400mm |
| Static Mechanical Load 1 | Downward pressure: 800 Pa ~ 12,000 Pa; | Static Mechanical Load 2 | Upward pull: 800 Pa ~ 6,000 Pa; |
| Dynamic Mechanical Load 1 | Downward pressure: -2,500 Pa ~ +2,500 Pa(Setting at software) | Dynamic Mechanical Load 2 | Cycle: 3~7 cycles/min |
| Brand Name | HAIDA | Place of Origin | Guangdong, China |
| High Light | Mechanical Load Test Machine ,PV Module Mechanical Load Test Machine | ||
Model: HD-E910
The Solar PV Module Mechanical Load Test Machine employs a combined forward pressure application and reverse suction pressure mode of operation, enabling it to meet the pressure testing requirements for photovoltaic modules under extreme climatic conditions such as deserts and plateaus.
| Feature | Specification |
|---|---|
| Cylinder-type device | Allows component sample to freely bend and deform under applied load, ensuring test surface pressure uniformity remains within ±5% |
| Pressure Method | Gradually and uniformly increase load until reaching set value, using both downward pressure and upward pull methods |
| Max sample size | 2600 × 1400mm (L × W) |
| Cylinder Space | Adjustable cylinder space |
| Cylinder Type | Low Friction |
| Cylinder Stroke | 400mm |
| Cylinder Quantity | 72 sets (12×6) - enables free adjustment of suction cup spacing in both horizontal and vertical directions at equal intervals |
| Cylinder distance | Cylinder Center Point Distance ≤20cm | Edge cylinder center distance from module edge ≤20cm |
| Deformation Detection | Infrared non-contact, deformation measurement range ±10 cm, accuracy ±0.5 mm, with 7 points that can be placed at any position within the same plane |
| DC Stabilized Power Supply | Powering 1 Module | DC Power Supply: 120V 5A |
| Static Mechanical Load | Downward pressure: 800 Pa ~ 12,000 Pa | Upward pull: 800 Pa ~ 6,000 Pa (Setting at software) |
| Dynamic Mechanical Load | Downward pressure: -2,500 Pa ~ +2,500 Pa (Setting at software) | Cycle: 3~7 cycles/min |
| Deflection Detection | Laser non-contact | Measurement range ≥10cm | Accuracy ±0.5mm | Measurement points: 5 points (can be placed at any position within the same plane) |
| Temperature Monitoring | Equipped with one temperature sensor (OMEGA T-type thermocouple) | Calibration point: 25°C |
| Controller | Capable of storing operational data, equipped with USB interface, enabling conversion of operational data into Excel/PDF files and charts |
| Safety Device | Air supply source equipped with safety valve and status indicator lights. In event of test failure, device will sound alarm and halt test |
| Air source | 0.6~0.8Mpa (prepared by user) |
| Power | Single-phase, 220V, 50Hz |
| Machine Dimension | Approximately 3700 × 2000 × 2300mm (W × D × H) |
Company Details
Business Type:
Manufacturer
Year Established:
2003
Total Annual:
5000000-7000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibration and after-sale service of test equipment, such as pap... Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibration and after-sale service of test equipment, such as pap...
Get in touch with us
Leave a Message, we will call you back quickly!