Payment Terms | L/C, Western Union, Western Union, T/T |
Delivery Time | 10-15 work days |
Type | DC/AC Inverters |
Output Type | Single-phase |
Output Current | 20mA |
Frequency Range | ±5% (47.5 ~ 63Hz) |
Output Frequency | 0.1-500Hz |
Nominal Capacity | 2.2 kW |
Vector control | 0–500 Hz |
View Detail Information
Explore similar products
AC220V 2.2kw 3HP Variable Frequency Drives VFD For Forging Machine Tool
AC220v 0.75kw 1HP Variable Frequency Drive For Metallurgical Equipment
Output 7A 50Hz 60Hz Variable Frequency Drives 1.5 Kw VFD VSD
380V 5.5kw 7.5HP VFD adjustable frequency drive Three Phase
Product Specification
Payment Terms | L/C, Western Union, Western Union, T/T | Delivery Time | 10-15 work days |
Type | DC/AC Inverters | Output Type | Single-phase |
Output Current | 20mA | Frequency Range | ±5% (47.5 ~ 63Hz) |
Output Frequency | 0.1-500Hz | Nominal Capacity | 2.2 kW |
Vector control | 0–500 Hz | ||
High Light | 2.2KW Single Phase Variable Frequency Drives ,20mA Variable Frequency Drives ,2.2KW Variable Frequency Drive VFD |
Output Single Phase Variable Frequency Drives VFD 220V 20mA 2.2KW
High Performance Single Phase Variable Frequency Drive 220 V 2.2 kW
Single Phase Variable Frequency Drive Description
The SVD-P is a general-purpose, high performance variable speed applications, offers a series of powerful features, idea for demanding application , compact, high efficiency
equipped with high start torque, overload capability,fast dynamic,built-in PID, PLC, offering a high precise motor control make of speed DSP, high margin IGBT Module, conformal coating, robust time-proven design
Features of Single Phase Variable Frequency Drive
SFVC/CLVC/VF
High Start Torque
Fast Dynamic
High Frequency & Torque stability
Flexible
Cost-effective
Housing types for different voltage and power classes
Voltage & Power Class | Housing Type |
Single-phase 220 V | |
0.4–2.2 kW | Plastic housing |
Three-phase 220 V | |
0.4–7.5 kW | Plastic housing |
11–75 kW | Sheet metal housing |
Three-phase 380 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 480 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 690 V | |
55–500 kW | 55–500 kW |
Technical specifications of the SVD-P
Item | Specifications | ||
Standard functions | Maximum frequency | • Vector control: 0–500 Hz • V/F control: 0–500 Hz | |
Carrier frequency | 0.5–16 kHz The carrier frequency is automatically adjusted based on the load features. | ||
Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% | ||
Control mode | • Sensorless flux vector control (SFVC) • Closed-loop vector control (CLVC) • Voltage/Frequency (V/F) control | ||
Startup torque | • G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC) • P type: 0.5 Hz/100% | ||
Speed range | 1:100 (SFVC) | 1:1000 (CLVC) | |
Speed stability accuracy | • ± 0.5% (SFVC) • ± 0.02% (CLVC) | ||
Torque control accuracy |
± 5% (CLVC) |
Item | Specifications | |
Standard functions |
Overload capacity | • G type: 60s for 150% of the rated current, 3s for 180% of the rated current • P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
Torque boost | • Fixed boost • Customized boost 0.1%–30.0% | |
V/F curve | • Straight-line V/F curve • Multi-point V/F curve • N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | |
V/F separation | Two types: complete separation; half separation | |
Ramp mode | • Straight-line ramp • S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0–6500.0s | |
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0–36.0s Braking action current value: 0.0%–100.0% | |
JOG control | JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s | |
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. | |
Onboard PID | It realizes process-controlled closed loop control system easily. | |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes. | |
Overvoltage/ Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent. | |
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode. | |
Individualized functions |
High performance | Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology. |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. | |
Rapid current limit | It helps to avoid frequent overcurrent faults of the AC drive. | |
Virtual I/Os | Five groups of virtual DI/Dos can realize simple logic control. | |
Timing control | Time range: 0.0–6500.0 minutes |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Total Annual:
1000000-5000000
Employee Number:
zgd001~zgd500
Ecer Certification:
Site Member
As a manufacturer with over 10 years of experience, Shenzhen ZGD Technology Co., Ltd. has more than 10 production lines which can produce 100,000 pieces of UPS every month. Over 10% of our staff members are engineers and professional technicians and more than 400 are skilled workers. Our company spe... As a manufacturer with over 10 years of experience, Shenzhen ZGD Technology Co., Ltd. has more than 10 production lines which can produce 100,000 pieces of UPS every month. Over 10% of our staff members are engineers and professional technicians and more than 400 are skilled workers. Our company spe...