| Explosion Proof Grade | Exia llC T6 Gb |
| Payment Terms | Western Union,T/T,D/P,D/A,L/C |
| Material Of Sensor | PVC or PTFE |
| Supply Ability | 100PCS/Month |
| Connection | Bluetooth/NB-iot/4G |
| Delivery Time | 5-8 work days |
| Protection Class | IP67 |
| Application Fields | mining and metallurgy indusrial |
| Process Pressurerange | Up to 40 bar |
| Protection Rating | IP67 or IP68 |
| Customized Support | OEM, ODM |
| Packaging Details | Carton or wooden box |
| Specification | Flange mounted and Thread mounted |
| Process Temperature | -40℃~+120℃ |
| Brand Name | QINWEIYB |
| Model Number | QWRD80G625 |
| Place of Origin | China |
View Detail Information
Explore similar products
Non-Contact Radar Level Gauge High Precision Anti-Interference
Cable Guided Wave Radar Liquid Level Measurement Wide Range Anti-Interference
Stable Reliable Rod-Type Guided Wave Radar Liquid Level Meter
Low-Frequency Radar Liquid Level Gauge Long Wavelength Penetration
Product Specification
| Explosion Proof Grade | Exia llC T6 Gb | Payment Terms | Western Union,T/T,D/P,D/A,L/C |
| Material Of Sensor | PVC or PTFE | Supply Ability | 100PCS/Month |
| Connection | Bluetooth/NB-iot/4G | Delivery Time | 5-8 work days |
| Protection Class | IP67 | Application Fields | mining and metallurgy indusrial |
| Process Pressurerange | Up to 40 bar | Protection Rating | IP67 or IP68 |
| Customized Support | OEM, ODM | Packaging Details | Carton or wooden box |
| Specification | Flange mounted and Thread mounted | Process Temperature | -40℃~+120℃ |
| Brand Name | QINWEIYB | Model Number | QWRD80G625 |
| Place of Origin | China | ||
| High Light | radar level gauge for water ,liquid level measurement radar ,cement level gauge radar | ||
Batch dips and sight glasses give snapshots, not control. When water towers, cement silos and process tanks must be monitored in real time, a continuous radar level gauge provides the uninterrupted level signal that automation, inventory and safety systems depend on, over long distances and through harsh conditions.
Many plants still check levels intermittently, with manual dipping, level switches or periodic visual inspection. This leaves blind windows between readings: a water tower can run dry, a cement silo can overflow, and a process tank can deviate from setpoint before anyone notices. Continuous level measurement closes these gaps by delivering a live level value at every moment, feeding directly into PLCs, SCADA and inventory systems. It enables automatic pump and valve control, accurate consumption accounting, overflow prevention and consistent product quality. Radar is the ideal continuous technology because it measures without contact, is unaffected by temperature, pressure, steam and dust, and works over the long ranges found in water storage and cement silos, with minimal maintenance over years of service.
The gauge transmits microwave signals toward the product surface and continuously processes the reflected echoes to calculate the distance, and therefore the level, in real time. Using high-frequency radar technology, it delivers a stable, repeating measurement rather than a single snapshot, updating the output continuously so control systems always see the current level. The signal is unaffected by the medium's density, viscosity or conductivity, and the non-contact design means no probe touches the water or cement, eliminating wear, coating and contamination. The continuous 4-20mA signal or digital output connects directly to controllers, providing real-time data for level control, high/low alarms, inventory tracking and reporting.
| Working Condition | Typical Failure | Why Discrete Checks Fail | Continuous Radar Solution |
|---|---|---|---|
| Water tower / reservoir supply management | Dry runs, overflow, supply gaps | Manual dips leave blind windows | Live level feeds pump control and alarms |
| Cement silo inventory and filling | Overfill, inaccurate stock, downtime | Level switches give no trend data | Continuous level enables reorder automation |
Case 1 - Municipal Water Tower Monitoring
Industry: Water supply
Application: Continuous level monitoring of elevated water towers
Measured Medium: Water
Range: 0-15 m
Process Temperature: -10 to +40 °C
Output Signal: 4-20 mA to pump control PLC
Key Challenge: Reliable round-the-clock supply management
Configuration: Continuous radar gauge with flange mounting
Installation: Top-mounted on tower roof
Performance Result: Automatic pump start/stop with live level
Customer Benefit: Uninterrupted supply and lower energy cost
Case 2 - Cement Silo Inventory Control
Industry: Construction materials
Application: Continuous inventory monitoring of cement silos
Measured Medium: Cement powder
Range: 0-30 m
Process Temperature: -10 to +60 °C
Output Signal: Digital output to inventory system
Key Challenge: Dusty atmosphere and long range
Configuration: Long-range radar version
Installation: Top-mounted on silo roof
Performance Result: Real-time stock levels during filling
Customer Benefit: Accurate reorder planning, no overfill
| Parameter | Specification |
|---|---|
| Measurement Type | Continuous non-contact radar |
| Applicable Media | Water, cement, liquids, slurries, powders |
| Measuring Range | Up to 30 m (long-range option) |
| Output Signal | 4-20 mA / digital communication |
| Environment Resistance | Temperature, pressure, steam, dust |
| Mounting | Top mounted, flange / thread |
| Housing Protection | IP-rated industrial housing |
| Warranty | 12 months |
Q1: What does continuous level measurement mean and why is it important?
Continuous level measurement means the instrument provides a live, updated level value at all times, rather than only detecting when a limit is reached or taking a reading on demand. This matters because industrial processes and supply systems constantly change: water is pumped out of towers, cement is drawn from silos, and process tanks are filled and emptied. Only a continuous signal lets control systems react immediately, automating pumps and valves, triggering alarms before overflow or dry-run, and building accurate inventory records. Without it, operators work from snapshots and react late. Continuous radar gives the real-time data that modern automation and management systems require.
Q2: Can one gauge really handle both water and cement?
Yes, because radar measures the surface of any medium that reflects microwaves, regardless of its density, viscosity or conductivity. Water is an excellent reflector with a strong, clean echo, while cement powder returns a weaker but still reliable echo that high-frequency radar processing handles well. The gauge's signal processing is configured for the specific medium and application, so the same instrument family covers water towers, process tanks and cement silos. This versatility simplifies procurement and spares inventory for plants that handle multiple media. Specify your media and vessel when ordering so the gauge is configured correctly.
Q3: How does the gauge handle steam, dust and temperature changes?
Radar signals are electromagnetic waves that travel through steam, dust and vapor with minimal attenuation, unlike ultrasonic signals which are sound waves and are scattered by these conditions. Temperature and pressure changes also have negligible effect on microwave propagation, so the measurement remains stable across wide operating variations. This makes radar particularly suitable for cement silos with filling dust, water systems with condensation, and process tanks with steam above the surface. The non-contact design additionally means no probe is exposed to the medium, so coating and corrosion do not degrade the reading over time.
Q4: What output does the gauge provide for automation integration?
The gauge provides a continuous output signal that connects directly to industrial control equipment. The standard 4-20mA analog signal interfaces with virtually every PLC, DCS and SCADA system, carrying the live level value for display, control and alarming. Digital communication options extend the integration with configuration access, diagnostics and multi-variable data where supported. This allows the gauge to drive automatic pump start/stop, valve control, high/low alarms, inventory tracking and reporting without additional signal conditioning. Our engineers can confirm the best output configuration for your existing control system.
Q5: What support and customization do you offer?
As the manufacturer, we provide direct technical support including range selection, mounting configuration and integration guidance. Customization options include measuring range, process connection, output protocol, housing material, labeling and packaging, plus OEM and ODM programs for system integrators and equipment distributors. Every unit is factory-calibrated and tested before shipment, and our engineers assist with application matching to ensure reliable long-term measurement. Contact us with your tank dimensions, media and control system details for a tailored recommendation and quotation.
Operations run on live data, not occasional checks. This continuous radar level gauge delivers real-time level values for water, cement and industrial tanks, with non-contact reliability, long-range reach and stable performance through steam, dust and temperature swings. It feeds directly into your PLC, SCADA and inventory systems, automating control and preventing the failures that come from blind windows. As the manufacturer, you receive a factory-calibrated instrument, application-matched configuration and direct engineering support. When your process must never lose sight of the level, choose the continuous radar gauge built for round-the-clock duty.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
Establishe
Total Annual:
5 million-10 million
Employee Number:
500~800
Ecer Certification:
Verified Supplier
.gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ... .gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ...
Get in touch with us
Leave a Message, we will call you back quickly!