Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Eccentric Orifice Plate Flowmeter Anti Clogging Anti Deposition For Dirty Medium","imgUrl":"https:\/\/img.chinax.com\/nimg\/1b\/e8\/9da081910df0c71aa660b972dfc2-200x200-1\/eccentric_orifice_plate_flowmeter_anti_clogging_anti_deposition_for_dirty_medium.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB108","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
{"title":"Anti Interference V Cone Flowmeter For Differential Pressure Flow Measurement","imgUrl":"https:\/\/img.chinax.com\/nimg\/15\/bf\/3ff7e3d9cd50fb48ffe64c12b709-200x200-1\/anti_interference_v_cone_flowmeter_for_differential_pressure_flow_measurement.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB101","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
{"title":"Segmental Wedge Flow Meter Anti Blocking Anti Pollution For Measuring Industrial","imgUrl":"https:\/\/img.chinax.com\/nimg\/6a\/a3\/968f6a7e55bf4b0c07a02f05c898-200x200-1\/segmental_wedge_flow_meter_anti_blocking_anti_pollution_for_measuring_industrial_fluids.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB102","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
{"title":"Annular Orifice Plate Flowmeter Dirt Resistant Anti Clogging For Precise Flow","imgUrl":"https:\/\/img.chinax.com\/nimg\/a1\/57\/3f4cbff65fe3f710c491da4937d9-200x200-1\/annular_orifice_plate_flowmeter_dirt_resistant_anti_clogging_for_precise_flow_measurement.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB103","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
{"title":"High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant","imgUrl":"https:\/\/img.chinax.com\/nimg\/6f\/83\/7d49055bebcf4fe60e27e5d13eff-200x200-1\/high_accuracy_venturi_flowmeter_low_pressure_loss_wear_resistant.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB105","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
{"title":"Venturi Differential Pressure Flow Meter , Stainless Steel Flow Nozzle Flow","imgUrl":"https:\/\/img.chinax.com\/nimg\/14\/7d\/bb2b3e6388bf9c05cc7df89edc4e-200x200-1\/venturi_differential_pressure_flow_meter_2c_stainless_steel_flow_nozzle_flow_meter.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB106","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
{"title":"Robust Structure Pitot Tube Flowmeter Stainless Steel Differential Pressure Flow","imgUrl":"https:\/\/img.chinax.com\/nimg\/e1\/ab\/9c876f5fabf1a6d7b0ffa08281a1-200x200-1\/robust_structure_pitot_tube_flowmeter_stainless_steel_differential_pressure_flow_meter.jpg","attrs":{"Brand Name":"QINWEIYB","Model Number":"QWLU-GB111","Place of Origin":"China","Minimum Order Quantity":"1Set"}}
Anti-Clogging And Anti-Deposition, Suitable For Dirty Medium Eccentric Orifice Plate Flowmeter
An eccentric orifice plate flowmeter refers to a circular opening whose center does not coincide with the center of the pipe (i.e., "eccentric").
Main advantages:
Anti-clogging and anti-deposition: This is the core advantage. For slurry, sewage, crude oil, etc., solid particles will pass through the lower part of the pipe along the mainstream and will not accumulate in front of the orifice plate.
Suitable for dirty media: It can measure liquids containing solids, easily crystallizing, easily settling, and gases/steam containing condensate.
Relatively small pressure loss: Compared with standard orifice plates, since the opening does not completely block the pipe, its permanent pressure loss is slightly lower.
The structure is still relatively simple, retaining the advantages of standard orifice plates such as durability and no moving parts.
Typical application scenarios
Liquids containing solid particles:
Slurry and coal slurry in mines and steel mills.
Sludge and wastewater in sewage treatment plants.
Pulp in paper mills.
Crude oil (containing sand and wax).
Gases/steam containing droplets or condensate:
Wet gas and humid compressed air.
Saturated steam or superheated steam (possibly carrying condensate).
Natural gas (possibly containing condensate oil).
The eccentric orifice plate flowmeter is a dedicated solution for specific challenges (measuring dirty media). It sacrifices the "standardization" and "high precision" advantages of standard orifice plates in exchange for the crucial practicality of "anti-clogging".