China factories

Chat Now Send Email
China factory - Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)

Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276
China Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276

  1. China Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276
  2. China Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276
  3. China Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276
  4. China Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276

Double Flange Level Gauge With 316L Stainless Steel / Hastelloy C-276

  1. MOQ: 1Set
  2. Price: Negotiable
  3. Get Latest Price
Connection Type Threaded
Measure Menttype Pressure and Level
Power Supply Battery/External Power
Output Signal 4-20mA / 0-10V
Accuracy ±1.5%
Operating Temperature -20°C to 80°C
Protection Rating IP65
Mounting Type Panel/Wall Mount
Payment Terms L/C,D/A,D/P,T/T
Supply Ability 100PCS/Month
Delivery Time 5-8 work days
Packaging Details Carton
Dimensions 150mm x 100mm x 75mm
Display Type Analog/Digital
Model Number QWBSQ-3052
Brand Name QINWEIYB
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Connection Type Threaded Measure Menttype Pressure and Level
Power Supply Battery/External Power Output Signal 4-20mA / 0-10V
Accuracy ±1.5% Operating Temperature -20°C to 80°C
Protection Rating IP65 Mounting Type Panel/Wall Mount
Payment Terms L/C,D/A,D/P,T/T Supply Ability 100PCS/Month
Delivery Time 5-8 work days Packaging Details Carton
Dimensions 150mm x 100mm x 75mm Display Type Analog/Digital
Model Number QWBSQ-3052 Brand Name QINWEIYB
Place of Origin China
High Light Double Flange Level GaugeHastelloy C-276 Flange Level Gauge316L Stainless Steel Level Gauge

Double Flange Level Transmitter with 316L & Hastelloy C-276 Remote Seals

1. Why You Need a Double Flange Level Transmitter

Closed, pressurized tanks present a measurement problem that open-tank gauges cannot solve: the vapor space above the liquid exerts its own pressure, so a simple gauge reading no longer equals liquid level. Any measurement must cancel the vapor pressure and, for vacuum systems, also account for atmospheric pressure influence. A double flange level transmitter solves this by sensing the pressure at both the bottom and the top of the vessel through remote capillary seals. The differential signal represents only the liquid column, giving a true level reading even in high-pressure, high-temperature, corrosive or crystallizing services where a direct-mounted transmitter would fail.

2. Working Principle of the Double Flange Level Transmitter

The transmitter is a differential-pressure instrument with two remote diaphragm seals. The high-pressure side flange mounts near the bottom of the vessel and senses the liquid head plus vapor pressure; the low-pressure side flange mounts near the top and senses the vapor pressure. Both diaphragms transmit pressure through liquid-filled capillaries (typically silicone oil) to a central sensing element, which outputs the pressure difference as a 4-20 mA signal. Because both sides share the same vapor pressure, it is automatically cancelled, leaving a signal proportional only to liquid level, density and gravity.

3. Double Flange Structure Advantages

  • Vacuum reference stability: top-side seal cancels vapor and atmospheric pressure influence for accurate level in closed and vacuum vessels.
  • High static pressure capability: flange ratings from Class 150 (2.5 MPa) to Class 600 (10 MPa), with up to 16 MPa capacity on select models.
  • Measurement accuracy: intelligent models reach ±0.1% FS with 100:1 to 200:1 turndown ratio.
  • Long-term reliability: ±0.25% FS stability over 5 years, vibration resistant (20g, 5-1000 Hz) and RFI immune (30 V/m).
  • Harsh environment tolerance: capillary insulation or heat tracing keeps error within ±0.05% FS even under ±20 °C ambient swings.

Common Measurement Challenges & Solutions

客户工况问题传统方案问题我们的解决方案最终收益
Closed pressurized tank levelGauge reading includes vapor pressure, giving false levelDual remote seals cancel vapor pressure differentiallyTrue liquid level independent of tank pressure
Strong acid / alkali media316L-only diaphragm corrodes quicklyHastelloy C-276 / tantalum diaphragm optionsExtended service life in aggressive chemistry
High static pressure (Class 600+)Standard seals deform and leakHigh-pressure flange ratings up to 10-16 MPaSafe, reliable measurement at elevated pressure
Ambient temperature swingsCapillary fill expands, causing zero driftInsulated / heat-traced capillaries with compensationError held within ±0.05% FS
Industry: Chemical
Application: Strong-acid storage tank level
Medium: Concentrated sulfuric acid
Pressure Range: 0-2.5 MPa
Operating Temperature: 20-60 °C
Installation Environment: Outdoor tank farm, corrosive atmosphere
Customer Challenge: Acid corroded standard 316L diaphragms within months
Previous Problem: Repeated sensor replacement and inaccurate inventory
Solution: Hastelloy C-276 double flange transmitter
Installation Location: Top and bottom tank flanges
Result: Multi-year service life, reliable acid level monitoring
Industry: Petrochemical
Application: Pressurized LPG / liquefied gas tank level
Medium: Liquefied petroleum gas
Pressure Range: up to 10 MPa
Operating Temperature: -20 to 40 °C
Installation Environment: Hazardous pressurized vessel
Customer Challenge: High vapor pressure distorted open-tank readings
Previous Problem: Inaccurate level, risk of overfill
Solution: Class 600 double flange differential transmitter
Installation Location: Top and bottom vessel flanges
Result: Accurate level with vapor pressure fully cancelled
Industry: Pharmaceutical
Application: Reactor / crystallizer level
Medium: Crystallizing API slurry
Pressure Range: 0-1.6 MPa
Operating Temperature: 10-120 °C
Installation Environment: Clean-room adjacent, sanitary
Customer Challenge: Crystals plugged standard pressure ports
Previous Problem: Frequent cleaning, batch inconsistency
Solution: 316L FDA electropolished double flange seals
Installation Location: Reactor top and bottom
Result: Plug-free measurement, consistent batch control
Industry: Water / Wastewater
Application: Ammonia water storage tank
Medium: Dilute ammonia / DMAC
Pressure Range: 0-1 MPa
Operating Temperature: Ambient to 60 °C
Installation Environment: Corrosive, scaling-prone
Customer Challenge: Scaling and corrosion degraded accuracy
Previous Problem: Drift and frequent recalibration
Solution: Tantalum diaphragm double flange transmitter
Installation Location: Tank top and bottom
Result: Stable, low-maintenance level control

Why Choose Our Double Flange Level Transmitter?

  • True differential measurement cancels vapor and atmospheric pressure influence
  • 316L, Hastelloy C-276 and tantalum diaphragm materials for aggressive media
  • High static pressure ratings from Class 150 up to Class 600 (16 MPa)
  • ±0.1% FS intelligent accuracy with 100:1 to 200:1 turndown
  • ±0.25% FS long-term stability over 5 years
  • FKM and PTFE seal options covering -40 °C to +260 °C
  • Insulated or heat-traced capillaries for ambient temperature compensation
  • Vibration resistant (20g) and RFI immune (30 V/m)
  • FDA electropolished 316L option for food and pharmaceutical use
  • 4-20 mA output with HART digital communication
Technical SpecificationValue
Measurement RangeDifferential, flange-rated
Accuracy±0.1% FS (intelligent), ±0.2% FS (analog)
Output Signal4-20 mA + HART
Process ConnectionRemote flange seals (capillary)
Wetted Material316L / Hastelloy C-276 / tantalum
Operating Temperature-40 °C to +260 °C (seal dependent)
Pressure ReferenceDifferential (top vs bottom seal)
Protection GradeIP65, static pressure up to 16 MPa

Q: What is a double flange level transmitter?

A double flange level transmitter is a differential-pressure instrument that measures the liquid level in closed tanks using two remote diaphragm seals connected by capillaries. One seal mounts at the bottom of the vessel (high-pressure side) and one at the top (low-pressure side). The transmitter subtracts the vapor pressure sensed at the top from the total pressure at the bottom, leaving only the hydrostatic pressure of the liquid column. This gives an accurate level signal regardless of the pressure inside the vessel, making it essential for pressurized, vacuum and corrosive applications.

Q: What is the difference between absolute pressure and gauge pressure?

Gauge pressure is measured relative to local atmospheric pressure, so it changes with weather and altitude. Absolute pressure is measured relative to a perfect vacuum and is independent of the atmosphere. In level measurement this distinction matters: a gauge reading of a sealed tank includes the vapor-space pressure, while a true level signal must isolate the liquid column. Double flange transmitters achieve this by measuring differentially, and absolute-pressure reference transmitters use an internal sealed vacuum chamber, so neither is affected by atmospheric pressure variations.

Q: Why use Hastelloy C-276 for the diaphragm?

Hastelloy C-276 is a nickel-molybdenum-chromium alloy with outstanding resistance to strong acids, alkalis, chlorides and oxidizing media that would quickly corrode 316L stainless steel. In chemical processes involving sulfuric, hydrochloric or phosphoric acid, or in seawater and chlorine environments, Hastelloy C-276 diaphragms dramatically extend sensor life and maintain accuracy. Selecting the correct wetted material is one of the most important decisions in level instrumentation, because a corroded diaphragm leads to drift, leakage and unplanned downtime.

Q: What is the purpose of the capillary in a double flange transmitter?

The capillary is a small-bore tube filled with a stable liquid, usually silicone oil, that transmits the process pressure from the remote flange diaphragm to the central sensing element. It allows the sensing electronics to be mounted away from hot, corrosive or vibrating process connections. The length, fill fluid and insulation of the capillary affect response time and temperature stability, so they are selected to match the process temperature and ambient conditions to minimize zero drift and measurement error.

Q: Can a double flange transmitter measure vacuum tanks?

Yes. Double flange transmitters are well suited to vacuum vessels because they measure the differential pressure between the bottom and top of the tank. In a vacuum, the vapor space pressure is below atmospheric, and a single gauge reference would be misleading. The top-side seal provides the correct reference so the output reflects only the liquid head. This makes the instrument reliable for vacuum distillation, evaporators and deaerators where both level and vacuum control are required.

Q: How accurate is a double flange level transmitter?

Intelligent models achieve ±0.1% of span, while analog versions typically reach ±0.2% of span, with turndown ratios of 100:1 and up to 200:1 on some models. Long-term stability is specified at ±0.25% FS over five years. Accuracy in service also depends on proper capillary selection, temperature compensation and correct zero/span calibration after installation, all of which help the transmitter hold its rated performance over a wide range of process conditions.

Q: Where are double flange level transmitters used?

They are used wherever liquid level must be measured in closed, pressurized, high-temperature or corrosive vessels. Typical industries include chemical, petrochemical, oil and gas, pharmaceutical, food and beverage, and water treatment. Applications range from reaction vessels, storage tanks and tank trucks to boilers and crystallizers, and they are especially valuable for media prone to crystallization, scaling, or containing solid particles or suspended matter.

Q: How do I select the correct seal material?

Seal selection depends on the process medium and temperature. FKM (fluororubber) suits -20 °C to +85 °C, while PTFE handles -40 °C to +260 °C and offers broader chemical resistance. For the wetted diaphragm, 316L works for general corrosive media, Hastelloy C-276 for strong acids and alkalis, and tantalum for the most aggressive chemicals such as aqua regia. For food and pharmaceutical use, FDA-certified electropolished 316L is required. Always match materials to the specific chemistry and temperature of your process.

Q: What are common faults and how are they resolved?

Output fluctuation is often caused by air bubbles in the capillary or diaphragm deformation and is resolved by venting air through the exhaust valve or replacing the diaphragm. Zero drift typically results from ambient temperature changes or silicone-oil aging, fixed by recalibration and checking temperature compensation. No output usually points to power-supply issues (check 24 VDC ±10%), poor cable insulation (≥20 MΩ required) or a HART protocol mismatch, and can be diagnosed using the transmitter's fault codes.

Q: How is a double flange transmitter installed?

The upper flange should be positioned near the top of the container and the lower flange near the bottom to ensure correct differential measurement. Flanges must be aligned and sealed to prevent leakage. The capillary should not be bent sharply or compressed, as this can damage the fill fluid path. Electrical cable should be routed downward to keep moisture out, and a zero and full-scale calibration should be performed after installation to confirm accuracy.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    Establishe

  • Total Annual:

    5 million-10 million

  • Employee Number:

    500~800

  • Ecer Certification:

    Verified Supplier

.gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ... .gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ...

+ Read More

Get in touch with us

  • Reach Us
  • Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)
  • No. 143, Sanqiao Street, Xi'an City, Shaanxi Province, China
  • https://www.radarlevelgauges.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement