Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Time Difference Non Contact Ultrasonic Flow Meter For Fluid Flow Efficient","imgUrl":"https:\/\/img.chinax.com\/nimg\/4d\/b6\/bf2bd6954517ba1ae319ec6c4b7f-200x200-1\/time_difference_non_contact_ultrasonic_flow_meter_for_fluid_flow_efficient.jpg","attrs":{"Pipe Size":"DN15mm-6000mm","Flow Range":"0.01 to 40 m\/s","Transmitter Enclosure":"IP65,ABS\/PC enclosure","Weight":"Transmitter:approximately1.0kg."}}
{"title":"Sectional Ultrasonic Flowmeter Wall Mount Insertion Type Ultrasonic Flow Meter","imgUrl":"https:\/\/img.chinax.com\/nimg\/44\/31\/16d7122d43f926128a6fa8dc476b-200x200-1\/sectional_ultrasonic_flowmeter_wall_mount_insertion_type_ultrasonic_flow_meter.jpg","attrs":{"Installation Method":"Wall Mount","Brand Name":"QINWEIYB","Model Number":"QWLW-GY203","Place of Origin":"China"}}
{"title":"Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement","imgUrl":"https:\/\/img.chinax.com\/nimg\/bb\/bf\/7e0177408c47eb69467b8ba68418-200x200-1\/ultrasonic_open_channel_flowmeter_4_20ma_output_ip65_for_non_contact_measurement.jpg","attrs":{"Output":"4-20mA,LCD Display,RS485","Name":"Easy Installation Ultrasonic Flowmeter","Power Supply":"24 VDC","Pipe Size Range":"1\"~48\" (25mm ~ 1200mm)"}}
{"title":"The Portable, Non-invasive, Fast And Flexible Measurement Expert - Handheld","imgUrl":"https:\/\/img.chinax.com\/nimg\/c5\/a5\/4d42791bd7a164f12cdd50d78ad9-200x200-1\/the_portable_2c_non_invasive_2c_fast_and_flexible_measurement_expert_handheld_ultrasonic_flowmeter.jpg","attrs":{"Skype":"summer.cao39","Operating Temperature":"-20\u00b0C to 80\u00b0C","Material":"Aluminum alloy or stainless steel housing","Output":"4-20mA,LCD Display,RS485"}}
{"title":"Modular Clamp On Ultrasonic Flowmeter \/ High Temperature Ultrasonic Flow Meter","imgUrl":"https:\/\/img.chinax.com\/nimg\/07\/96\/b2813830e809f66501459bb6b9e9-200x200-1\/modular_clamp_on_ultrasonic_flowmeter_2f_high_temperature_ultrasonic_flow_meter.jpg","attrs":{"Flow Range":"0.01 to 40 m\/s","Pipe Size":"Clamp-on:1\"~48\"(25mm~1200mm)","Transmitter Enclosure":"IP65,ABS\/PC enclosure","Skype":"summer.cao39"}}
{"title":"High Precision Ultrasonic Heat Meter , Remote Transmission Water Meter 4-20mA","imgUrl":"https:\/\/img.chinax.com\/nimg\/d9\/00\/8226a3817feea8b350ec6e589685-200x200-1\/high_precision_ultrasonic_heat_meter_2c_remote_transmission_water_meter_4_20ma.jpg","attrs":{"Transducer":"Encapsulated design,IP68","Output Signal":"4-20mA, Pulse, Frequency, Modbus, HART","Pipe Size":"Clamp-on:1\"~48\"(25mm~1200mm)","Power Supply":"24 V DC or 110\/220 V AC"}}
Time-Difference Ultrasonic Flowmeter For Efficient Measurement Of Fluid Flow
The time difference method ultrasonic flowmeter is a high-precision non-contact measuring instrument that calculates flow velocity and flow rate by utilizing the time difference of ultrasonic waves traveling in the fluid in the downstream and upstream directions.
Main Features
High Precision: It is the most accurate ultrasonic flowmeter, with an accuracy of ±0.5% or even higher, suitable for trade settlement.
Wide Range Ratio: It has a wide measurement range, typically over 1:100, capable of meeting the measurement requirements of both low and high flow rates simultaneously.
No Pressure Loss: No components are inserted into the flow channel, thus not impeding the fluid flow at all and saving pumping energy.
Multi-functional: It can measure forward and reverse flow, instantaneous and cumulative flow, and provide diagnostic information such as sound velocity and signal quality.
Broad Medium Compatibility: It is suitable for measuring clean, single-phase, homogeneous liquids, such as tap water, pure water, fuel oil, solvents, chemical reagents, etc.
Installation methods
There are mainly three installation methods for the time difference method:
Installation method
Principle
Advantages
Disadvantages
Scenarios
External clamp type
The probe is fixed to the outer wall of the pipe with coupling agent.
Non-stop installation, no pressure loss, easy maintenance.
Highly affected by pipe material and condition, extremely high installation requirements.
Temporary detection, energy audits, processes where shutdown is difficult.
Insertion type
A hole is drilled in the pipe and the probe is directly inserted into the fluid.
High accuracy, good stability, not affected by pipe wall.
Requires shutdown for installation, slight pressure loss, contact with medium.
Permanent installation, large-diameter pipes with high accuracy requirements.
Pipe section type
The probe is pre-installed on a standard short pipe to form an integrated unit.
Highest accuracy, precisely calibrated before leaving the factory, simple installation.
Measurement medium
Clean fluid: Mainly suitable for clean water, pure water, oil, chemical solvents and other liquids without suspended particles or bubbles.
High precision requirements: Widely used in water supply companies, industrial circulating water, food and beverage, pharmaceutical and other fields with high measurement accuracy requirements.
Extreme working conditions: Some models can withstand high temperatures (-200℃ to 200℃), high pressure and strong corrosive media (such as concentrated sulfuric acid).
Typical Applications
Municipal water supply: Pipeline flow monitoring, leakage detection.
Industrial fields: Petrochemical (LNG transportation), semiconductor ultra-pure water, food and beverage filling, etc.
Open channel flow measurement: Large channel flow monitoring, supporting solar power supply and remote data transmission.
Summary: The time difference method ultrasonic flowmeter is a high-end solution for clean liquid flow measurement. Its successful application highly depends on "correct selection + professional installation + accurate parameters". Under the premise of meeting its working conditions, it can provide unparalleled long-term measurement performance and reliability.