China factories

Chat Now Send Email
China factory - Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)

Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator
China Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator

  1. China Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator
  2. China Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator
  3. China Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator
  4. China Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator

Oil Pressure Calibration Bench 6MPa -80Kpa Vacuum Gauge Calibrator

  1. MOQ: 1Set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T
Supply Ability 100PCS/Month
Delivery Time 5-8 work days
Packaging Details Carton
Working Temperature 5~50℃
Range -0.1~60MPa
Type Gauge, Absolute, Sealed gauge
Voltage 5±0.5VDc
Output Type Analog and Digital
Stability ± 0.10% of URL for 12 months
Flange Pressure 1/4 - 18 NPT thread
Power 5VDC / 12VDC/24VDC /9-30vdc
Electrical Connection M12 Connector
Accuracy ±0.1% FS
Brand Name QINWEIYB
Model Number QWYB-510
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T Supply Ability 100PCS/Month
Delivery Time 5-8 work days Packaging Details Carton
Working Temperature 5~50℃ Range -0.1~60MPa
Type Gauge, Absolute, Sealed gauge Voltage 5±0.5VDc
Output Type Analog and Digital Stability ± 0.10% of URL for 12 months
Flange Pressure 1/4 - 18 NPT thread Power 5VDC / 12VDC/24VDC /9-30vdc
Electrical Connection M12 Connector Accuracy ±0.1% FS
Brand Name QINWEIYB Model Number QWYB-510
Place of Origin China
High Light Oil Pressure Calibration6MPa Vacuum Gauge Calibrator80Kpa Vacuum Gauge Calibrator

Oil Pressure Calibration Bench for Pressure Gauge and Transmitter Verification

1. Why You Need It

Every plant that relies on pressure measurement needs a trusted reference to verify its gauges and transmitters against — otherwise, calibration drifts go unnoticed until they cause process errors or safety issues. This oil pressure calibration bench generates stable pressures from -80 kPa vacuum to 60 MPa, letting technicians calibrate and verify pressure gauges, transmitters and switches against a ±0.1% FS reference. It is the metrology workhorse for instrument workshops, quality labs and field service teams.

2. Working Principle

The calibration bench uses a hand pump or pneumatic/hydraulic pressure source to generate a precise, adjustable test pressure, with oil as the pressure-transmitting medium for high ranges. The pressure under test is compared against an internal high-accuracy reference, and the instrument under test is adjusted to match. With analog and digital output options, the bench provides a stable, repeatable reference for verifying measurement accuracy across a wide range.

3. Key Advantages

  • Range -0.1 to 60 MPa (vacuum to high)
  • ±0.1% FS reference accuracy
  • Analog and digital output
  • Gauge / absolute / sealed gauge
  • 5-50 °C working temperature
  • Multiple power options (5/12/24 V)
  • M12 electrical connection
  • ±0.10% URL 12-month stability
  • Suitable for gauges and transmitters
  • Portable bench-top design

Common Pain Points & Solutions

ProblemConventional IssueOur SolutionResult
Unverified instrumentsCalibration drifts unnoticed±0.1% FS reference benchTrusted calibration verification
Wide pressure coverage neededSingle-range calibrators limited-0.1 to 60 MPa rangeOne bench, many instruments
Vacuum calibration difficultPressure-only calibrators-80 kPa vacuum capabilityFull vacuum and pressure testing
Reference drift over timeUnstable references±0.10% URL / 12-month stabilityConsistent calibration results

Application Cases

Industry: Instrument Workshop
Application: Periodic gauge calibration
Medium: Hydraulic oil
Pressure Range: -0.1 to 60 MPa
Operating Temperature: 5-40 °C
Installation Environment: Workshop
Customer Challenge: Verify gauge accuracy
Previous Problem: No reliable reference
Solution: Calibration bench, ±0.1% FS
Installation Location: Calibration bench
Result: Traceable gauge verification
Industry: Quality Lab
Application: Transmitter acceptance testing
Medium: Oil
Pressure Range: 0-60 MPa
Operating Temperature: 20-25 °C
Installation Environment: Metrology lab
Customer Challenge: Validate incoming transmitters
Previous Problem: Unverified instruments
Solution: Bench with digital output
Installation Location: Test station
Result: Validated transmitter accuracy
Industry: Field Service
Application: On-site gauge checking
Medium: Oil
Pressure Range: -0.1 to 6 MPa
Operating Temperature: 5-45 °C
Installation Environment: Plant site
Customer Challenge: Portable calibration
Previous Problem: Bulky, fixed rigs
Solution: Portable calibration bench
Installation Location: Instrument bay
Result: Convenient on-site calibration
Industry: Process Plant
Application: Pressure switch set-point check
Medium: Oil
Pressure Range: 0-10 MPa
Operating Temperature: 10-40 °C
Installation Environment: Maintenance shop
Customer Challenge: Verify switch set points
Previous Problem: Manual, imprecise checks
Solution: Bench, analog + digital
Installation Location: Maintenance shop
Result: Accurate switch verification

Technical Specifications

SpecificationValue
Measurement Range-0.1 to 60 MPa
Accuracy±0.1% FS
Stability±0.10% URL / 12 months
Output TypeAnalog and digital
Pressure TypeGauge / Absolute / Sealed Gauge
Working Temperature5-50 °C
Power Supply5 / 12 / 24 V DC (9-30 V DC)
Electrical ConnectionM12

FAQ

Q: What is a pressure calibration bench?

A pressure calibration bench is a precision instrument used to generate known pressures and compare them against the reading of a pressure gauge, transmitter or switch. It provides a stable reference pressure so technicians can verify accuracy, adjust calibration and document traceability. It is the standard tool in instrument workshops and calibration laboratories.

Q: What is the pressure range?

The bench covers a range of -0.1 to 60 MPa, spanning deep vacuum (-80 kPa) through to high pressure (60 MPa). This wide range allows calibration of most industrial pressure gauges, transmitters and switches with a single bench, eliminating the need for multiple calibrators.

Q: How accurate is it?

The reference accuracy is ±0.1% FS, providing a trustworthy standard for verifying field instruments that typically have 0.25-1% FS accuracy. The ±0.10% URL stability over 12 months ensures the reference itself remains reliable between recalibrations.

Q: Can it calibrate vacuum instruments?

Yes, the bench generates pressures down to -80 kPa vacuum, so it can calibrate vacuum gauges and transmitters as well as positive-pressure instruments. This vacuum capability is important for process plants that use vacuum measurement and need to verify those instruments.

Q: What instruments can it calibrate?

It can calibrate pressure gauges, pressure transmitters, pressure transducers and pressure switches. The analog and digital outputs and the wide range allow the bench to drive and verify almost any pressure instrument used in industrial service.

Q: Why use oil as the medium?

Oil is used as the pressure-transmitting medium for high pressure ranges because it is incompressible and provides stable, controllable pressure without the risk of gas expansion. For lower ranges and vacuum, the bench's pressure source is configured accordingly. Oil-filled systems are standard for high-pressure calibration.

Q: What output does it provide?

The bench provides analog and digital output options, allowing it to interface with the instrument under test and with data-logging or documentation systems. This supports both manual calibration and automated, traceable calibration procedures.

Q: How is it powered?

It supports multiple power options — 5 V DC, 12 V DC, 24 V DC and 9-30 V DC — making it flexible for different workshop and field power sources. The M12 electrical connection provides a secure interface.

Q: How often should the bench be recalibrated?

The bench itself should be recalibrated against a higher-level standard on a periodic basis, typically annually, to maintain its ±0.1% FS reference accuracy. Its ±0.10% URL 12-month stability means it holds its calibration well, but traceability to a national standard is maintained through periodic recalibration.

Q: Where is it used?

It is used in instrument workshops, quality and metrology laboratories, field service teams and process plant maintenance shops. Anywhere pressure gauges, transmitters and switches must be verified and calibrated to maintain measurement accuracy and traceability.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    Establishe

  • Total Annual:

    5 million-10 million

  • Employee Number:

    500~800

  • Ecer Certification:

    Verified Supplier

.gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ... .gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ...

+ Read More

Get in touch with us

  • Reach Us
  • Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)
  • No. 143, Sanqiao Street, Xi'an City, Shaanxi Province, China
  • https://www.radarlevelgauges.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement