| Precision | <0.1% |
| Process Connection | Flange From DN80 |
| Measurement Principle | Microwave radar |
| Power Supply | Two Wires DC24±6V; Four Wires AC220V |
| Measuring Frequency | 80Hz |
| Payment Terms | L/C,D/A,D/P,T/T |
| Supply Ability | 100PCS/Month |
| Delivery Time | 5-8 work days |
| Packaging Details | Carton |
| Medium temperature | -40~250℃,-40 C~150 C,-40 ℃ ~ 250℃ |
| Material | Stainless steel housing |
| Application | powder,corrosive liquid,strong dust etc,Solid particles,heavy steam conditions |
| Brand Name | QINWEIYB |
| Model Number | QWRD80G609 |
| Certification | Explosion-proof certificate ,Safety certificate |
| Place of Origin | China |
View Detail Information
Explore similar products
Non-Contact Radar Level Gauge High Precision Anti-Interference
Cable Guided Wave Radar Liquid Level Measurement Wide Range Anti-Interference
Stable Reliable Rod-Type Guided Wave Radar Liquid Level Meter
Low-Frequency Radar Liquid Level Gauge Long Wavelength Penetration
Product Specification
| Precision | <0.1% | Process Connection | Flange From DN80 |
| Measurement Principle | Microwave radar | Power Supply | Two Wires DC24±6V; Four Wires AC220V |
| Measuring Frequency | 80Hz | Payment Terms | L/C,D/A,D/P,T/T |
| Supply Ability | 100PCS/Month | Delivery Time | 5-8 work days |
| Packaging Details | Carton | Medium temperature | -40~250℃,-40 C~150 C,-40 ℃ ~ 250℃ |
| Material | Stainless steel housing | Application | powder,corrosive liquid,strong dust etc,Solid particles,heavy steam conditions |
| Brand Name | QINWEIYB | Model Number | QWRD80G609 |
| Certification | Explosion-proof certificate ,Safety certificate | Place of Origin | China |
| High Light | Continuous Wave Radar Level Sensor ,Radar Level Sensor 80Hz ,Explosion Proof Radar Level Transmitter | ||
Hazardous areas demand instruments that are certified safe and still measure reliably through the toughest conditions: dust, powders, corrosive vapors and heavy steam. The QWRD80G609 explosion proof FMCW radar level sensor delivers certified protection, <0.1% precision and a -40 to +250 °C rating for the most demanding solid and liquid level applications.
In plants handling flammable dusts, gases and vapors, every instrument must be certified for the hazardous area, because a single ignition source can turn a storage silo or process vessel into a catastrophe. At the same time, the media in these plants are often the hardest to measure: powders that create dust clouds, corrosive chemicals that attack sensors, and processes with heavy steam that blind ultrasonic and optical instruments. A continuous wave radar with explosion proof certification answers both requirements: it is approved for hazardous installation, and its FMCW microwave measurement penetrates dust, steam and vapor to deliver precise, non-contact level data. For cement, chemicals, food powders, plastics and petrochemicals, this combination of safety and capability is exactly what the application demands.
The QWRD80G609 transmits a continuous, frequency-modulated microwave signal toward the product surface. The reflected signal is compared with the transmitted signal, and the frequency difference, which is proportional to distance, is processed to calculate the level with a precision better than 0.1%. The 80GHz high-frequency signal penetrates dust clouds and steam atmospheres that defeat lower-frequency instruments, while the non-contact measurement avoids wear and contamination from abrasive powders and corrosive media. The instrument is housed in a stainless steel explosion proof enclosure certified for hazardous areas, and can be powered as a two-wire loop at DC 24±6 V or as a four-wire unit at AC 220 V, with a process temperature capability of -40 to +250 °C.
| Working Condition | Typical Failure | Why Ordinary Instruments Fail | QWRD80G609 Solution |
|---|---|---|---|
| Flammable dust and gas atmospheres | Ignition risk, regulatory non-compliance | Non-certified electronics | Explosion proof certified enclosure |
| Dust clouds, corrosive vapors, heavy steam | Signal loss, sensor corrosion | Ultrasonic/optical blocked; contact sensors attacked | 80GHz FMCW penetrates atmosphere; non-contact design |
Case 1 - Powder Storage Silo in Chemical Plant
Industry: Chemical manufacturing
Application: Level monitoring of flammable powder storage silos
Measured Medium: Chemical powders
Range: 0-30 m
Process Temperature: -10 to +80 °C
Output Signal: 4-20 mA + HART to DCS
Key Challenge: Explosion hazard plus dust clouds during filling
Configuration: QWRD80G609 explosion proof version, flange DN80
Installation: Top-mounted on silo roof
Performance Result: Certified-safe, stable readings during pneumatic filling
Customer Benefit: Safe, accurate inventory in a hazardous area
Case 2 - High-Temperature Process Vessel
Industry: Petrochemical / refining
Application: Level measurement in high-temperature process vessels
Measured Medium: Hot hydrocarbons and vapors
Range: 0-15 m
Process Temperature: Up to 250 °C
Output Signal: 4-20 mA to process control
Key Challenge: Extreme heat and heavy vapor above the liquid
Configuration: QWRD80G609 high-temperature version with AC220V supply
Installation: Top-mounted with high-temperature flange
Performance Result: Precise level data despite heat and vapor
Customer Benefit: Reliable process control in severe conditions
| Parameter | Specification |
|---|---|
| Precision | <0.1% |
| Measuring Frequency | 80 GHz (continuous wave FMCW) |
| Process Temperature | -40 to +250 °C |
| Power Supply | Two wires DC24±6V / Four wires AC220V |
| Process Connection | Flange from DN80 |
| Housing Material | Stainless steel |
| Certification | Explosion proof certificate |
| Warranty | 12 months |
Q1: What is continuous wave radar level measurement?
Continuous wave radar, also called FMCW (frequency-modulated continuous wave) radar, transmits a continuous microwave signal whose frequency sweeps linearly over time instead of sending short pulses. The signal reflects off the product surface, and the electronics measure the frequency difference between the transmitted and reflected signals at the same instant. Because this frequency difference is directly proportional to the distance to the surface, the level is calculated with high resolution and precision. Continuous wave radar provides superior signal processing compared with pulse radar, making it more reliable in difficult conditions such as dust, steam, condensation and weak reflections from powders and solids.
Q2: Why is explosion proof certification important for this sensor?
Explosion proof certification means the sensor has been tested and approved for installation in hazardous areas where flammable gases, vapors or dusts may be present. The instrument is designed to contain any internal ignition so that it cannot ignite the surrounding atmosphere. Installing a non-certified instrument in a hazardous area creates a serious risk of fire or explosion and violates safety regulations. The QWRD80G609 carries explosion proof certification, making it suitable for silos and vessels handling flammable powders, chemicals and hydrocarbons. When ordering, please specify your area classification so we can confirm the certification matches your installation requirements.
Q3: How does the sensor measure through dust and steam?
Dust and steam scatter and attenuate measurement signals, which defeats ultrasonic sensors and low-frequency radars. The QWRD80G609 uses an 80GHz high-frequency microwave signal, whose short wavelength penetrates dust clouds, vapor and heavy steam far more effectively than lower frequencies. In addition, the FMCW continuous wave processing analyzes the complete frequency spectrum of the return signal, allowing the electronics to identify the true product echo among the noise created by suspended particles and droplets. This combination keeps the level reading stable and accurate even during pneumatic filling of silos and in vessels with heavy condensation and vapor.
Q4: What power supply options are available?
The QWRD80G609 offers two power supply configurations. The two-wire version operates on DC 24±6 V, using the same two wires for power and the 4-20 mA signal, which is the standard loop-powered arrangement in most plants. The four-wire version operates on AC 220 V, providing a separate power supply with independent signal wiring, which is convenient where AC power is readily available or where higher power is needed for certain configurations. This flexibility allows the sensor to be integrated into plants with either DC loop infrastructure or AC power distribution, simplifying installation in both new and existing facilities.
Q5: What customization and support do you provide?
As the manufacturer, we provide direct engineering support for the QWRD80G609, including hazardous area classification guidance, antenna and flange selection, and installation advice. Customization options include measuring range, process connection from DN80 and above, antenna types for different media, power supply configuration, output protocol, labeling and packaging, plus OEM and ODM programs. With a monthly supply capacity of 100 pieces and delivery within 5-8 working days, we support both individual projects and series production. Contact us with your area classification, media and vessel details for a recommendation and quotation.
Safety and measurement performance are not negotiable in hazardous processes, and the QWRD80G609 delivers both. Its explosion proof certification, 80GHz FMCW technology, <0.1% precision and -40 to +250 °C capability make it the dependable choice for powder silos, corrosive service and high-temperature vessels. As the manufacturer, you receive certified instruments, flexible power and connection options, and direct engineering support. When the atmosphere is hazardous and the media is demanding, choose the radar sensor that is certified for both.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
Establishe
Total Annual:
5 million-10 million
Employee Number:
500~800
Ecer Certification:
Verified Supplier
.gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ... .gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ...
Get in touch with us
Leave a Message, we will call you back quickly!