| Measuring Range | 0-30 m |
| Process Connection | Flange DN50-DN100 |
| Payment Terms | T/T, L/C, PayPal, Western Union |
| Supply Ability | 800 Pieces per Month |
| Output Signal | 4-20 mA + HART |
| Diaphragm Material | 316L / PTFE-lined |
| Diaphragm Type | Flush, level with flange face |
| Media Capability | Viscous, crystallizing, slurry |
| Delivery Time | 5-8 working days |
| Packaging Details | Export-grade carton with foam protection |
| Place of Origin | Guangdong, China |
| Model Number | QWY-FLT201 |
| Brand Name | QINWEIYB |
| Certification | ISO 9001:2015 |
View Detail Information
Explore similar products
Single Flange Level Transmitter Explosion Proof Diaphragm Gauge
Immersion Level Gauge Stainless Steel Panel Mount Measurement
Threaded Installation Pressure Transmitter Panel Surface Mount
Flange Type High Pressure Temperature Transmitter Viscous Media
Product Specification
| Measuring Range | 0-30 m | Process Connection | Flange DN50-DN100 |
| Payment Terms | T/T, L/C, PayPal, Western Union | Supply Ability | 800 Pieces per Month |
| Output Signal | 4-20 mA + HART | Diaphragm Material | 316L / PTFE-lined |
| Diaphragm Type | Flush, level with flange face | Media Capability | Viscous, crystallizing, slurry |
| Delivery Time | 5-8 working days | Packaging Details | Export-grade carton with foam protection |
| Place of Origin | Guangdong, China | Model Number | QWY-FLT201 |
| Brand Name | QINWEIYB | Certification | ISO 9001:2015 |
| High Light | Flush Diaphragm Anti Blocking Design ,Chemical Tank Level Measurement ,HART Flange Level Transmitter | ||
Sticky, crystallizing and slurry media are the enemies of level measurement: they clog, coat and block conventional sensors. The flange mounted level transmitter uses a flush diaphragm that sits level with the flange face, giving anti-blocking performance for chemical tanks, slurry vessels and viscous liquid storage with HART output.
In chemical plants and processing facilities, tanks hold liquids that are viscous, crystallizing, slurry-like or laden with solids. Traditional level sensors with exposed diaphragms or protruding probes quickly become blocked or coated: material builds up on the sensing element, the reading drifts, and the sensor eventually fails. A flange mounted transmitter solves this with a flush diaphragm: the pressure-sensitive diaphragm is mounted level with the flange face, so there is no cavity or protrusion where material can accumulate. The hydrostatic pressure of the liquid column is transmitted through the diaphragm to the sensing element, giving accurate level data while the flush design resists blocking, coating and crystallization. The flange connection also provides a strong, leak-free mount on tank nozzles, and the HART output allows remote configuration and diagnostics. For tanks handling difficult media, the flange mounted flush diaphragm transmitter is the dependable choice.
The transmitter measures level through the hydrostatic pressure of the liquid column in the tank. The flush diaphragm, mounted on the flange face at a known height above the tank bottom, is in direct contact with the liquid; the pressure on the diaphragm increases with the liquid level above it. The sensing element behind the diaphragm converts this pressure into an electronic signal, and the electronics calculate the level by subtracting the known mounting height and compensating for the liquid's density. Because the diaphragm is flush with the flange, no material can lodge in a cavity or build up on a protruding element. The level value is transmitted as a 4-20mA signal with HART digital communication, allowing configuration, calibration and diagnostics from a control room or handheld communicator.
Select the flange size and rating to match your tank nozzle, and choose the diaphragm material compatible with your liquid, considering concentration and temperature. The transmitter should be mounted at a height that keeps the diaphragm covered by liquid at the minimum level to be measured, and the level calculation accounts for the vertical distance between the diaphragm and the tank bottom. For crystallizing or highly viscous media, the flush diaphragm should be mounted vertically or at an angle that allows material to fall away. The HART output connects to your control system with standard two-wire wiring, and the transmitter can be configured for the tank height and liquid density during commissioning. Our engineers support the complete selection and installation process.
| Working Condition | Typical Failure | Why Conventional Sensors Fail | Flush Diaphragm Solution |
|---|---|---|---|
| Viscous and sticky liquids | Coating, drifting readings | Material builds up on sensors | Flush face, nothing to accumulate on |
| Crystallizing media | Blockage, false level | Crystals lodge in cavities | No cavity, crystals fall away |
| Slurries with solids | Probe damage, clogging | Solids block protruding elements | Flush diaphragm resists blocking |
| Corrosive chemicals | Sensor corrosion, failure | Incompatible materials | Corrosion-resistant diaphragm options |
Case 1 - Chemical Storage Tank with Crystallizing Liquid
Industry: Chemical manufacturing
Application: Level monitoring of crystallizing chemical storage
Measured Medium: Salt solution with crystals
Range: 0-6 m
Process Temperature: 10-60 °C
Output Signal: 4-20 mA + HART to DCS
Key Challenge: Crystal buildup blocking conventional sensors
Configuration: Flush diaphragm, PTFE-lined flange
Installation: Side mounted on tank nozzle
Performance Result: No blockage, stable level readings
Case 2 - Slurry Storage Vessel
Industry: Mining and mineral processing
Application: Level monitoring of slurry storage vessels
Measured Medium: Mineral slurry with solids
Range: 0-8 m
Process Temperature: 10-50 °C
Output Signal: 4-20 mA to process control
Key Challenge: Abrasive solids and settling material
Configuration: Flush diaphragm with hardened face
Installation: Side mounted on vessel wall
Performance Result: Reliable level despite solids
| Parameter | Specification |
|---|---|
| Diaphragm Type | Flush, level with flange face |
| Process Connection | Flange (DN50-DN100, customizable) |
| Output Signal | 4-20 mA + HART |
| Measuring Range | 0-30 m (configurable) |
| Diaphragm Material | 316L / PTFE-lined (options) |
| Media Capability | Viscous, crystallizing, slurry, corrosive |
| Supply Voltage | 12-36 VDC (typical 24 VDC) |
| Process Temperature | -20 to +120 °C (media) |
| Overload Capacity | 2x FS |
| Electrical Connection | Terminal block, cable gland |
Q1: What is a flush diaphragm level transmitter?
A flush diaphragm level transmitter is a pressure-based level instrument whose sensing diaphragm is mounted level with the flange face, rather than recessed behind a nozzle or covered by a protective cavity. This flush design is the key to its anti-blocking performance: because there is no recess, cavity or protruding element, viscous liquids, crystallizing media and slurries have nothing to accumulate on or lodge in. The liquid's hydrostatic pressure acts directly on the flush diaphragm and is converted into a level value. This makes the transmitter the preferred choice for tanks containing sticky, crystallizing, slurry-like or solid-laden media where conventional sensors become blocked and unreliable.
Q2: Why does material buildup cause measurement failure?
Material buildup affects level sensors in two ways. First, when media accumulates on or around the sensing element, it creates a barrier that changes how pressure or signal is transmitted, so the reading drifts even though the actual level has not changed. Second, buildup in cavities, nozzles or on protruding probes can harden and block the sensor completely, causing false readings or total failure. For crystallizing media, crystals growing in the sensor cavity physically prevent the diaphragm from moving. The flush diaphragm avoids both problems by presenting a smooth, level surface where material cannot accumulate, and where any slight deposit falls away or is washed off by the liquid itself.
Q3: How is the level calculated from the pressure?
The level is calculated from the hydrostatic pressure using the relationship where pressure equals liquid density times gravity times the height of the liquid column. The transmitter measures the pressure at its mounting height, which is the pressure of the liquid above that point. To obtain the total level, the electronics add the known vertical distance from the diaphragm to the tank bottom, and the result is scaled using the liquid's density, which is configured during commissioning. Because the calculation depends on density, the transmitter is configured for the specific liquid in the tank; if the liquid changes, the density setting is updated through HART configuration. This gives an accurate level value in meters or other units.
Q4: What flange and material options are available?
The transmitter is available with flange sizes and ratings to match your tank nozzle, typically DN50 to DN100 and above, in standard or customized pressure ratings. The diaphragm and wetted parts can be supplied in 316L stainless steel for general chemical service, or with PTFE lining and protective coatings for highly corrosive media such as strong acids and alkalis. For abrasive slurries, hardened diaphragm faces extend service life. When ordering, specify your liquid, its concentration, temperature, pressure and flange requirement, and our engineers will select the correct material and configuration for reliable long-term service.
Q5: How does HART communication help?
HART (Highway Addressable Remote Transducer) superimposes a digital communication signal on the standard 4-20mA analog output, using the same two wires. This gives you the best of both worlds: the analog 4-20mA signal connects directly to PLC and DCS inputs for control, while the digital channel allows remote configuration of range, units, damping and density, plus access to live process values and diagnostics. A technician can configure and troubleshoot the transmitter from a control room or with a handheld communicator without climbing to the tank, reducing commissioning time and improving safety. HART is the most widely supported communication protocol in process plants, ensuring easy integration.
Q6: What support and customization do you offer?
As the manufacturer, we provide direct technical support including flange selection, material compatibility advice, density configuration and installation guidance. Customization options include flange size and rating, diaphragm material, measuring range, output protocol, housing options, labeling and packaging, plus OEM and ODM programs. Every transmitter is factory-calibrated and tested before shipment. Contact us with your tank dimensions, liquid properties and control system details for a tailored recommendation and quotation.
When your tank holds media that blocks, coats and crystallizes, only a flush design keeps measuring. This flange mounted transmitter presents a smooth, level diaphragm to the liquid, eliminating the cavities where material accumulates, and its corrosion-resistant materials and HART output make it a dependable chemical plant workhorse. As the manufacturer, you receive factory calibration, application-matched flange and material configuration, and direct engineering support. When the media is difficult and the level must be true, choose the flush diaphragm transmitter that never blocks.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
Establishe
Total Annual:
5 million-10 million
Employee Number:
500~800
Ecer Certification:
Verified Supplier
.gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ... .gtr-container-q2w3e4 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-q2w3e4 p { ...
Get in touch with us
Leave a Message, we will call you back quickly!