| Payment Terms | L/C, T/T |
| Supply Ability | 450Mwh/year |
| Delivery Time | 2~4weeks for samples; 4~6weeks for mass production |
| Packaging Details | standard export carton |
| Material | LiFePO4 |
| Norminal voltage | 76.8V |
| Norminal capacity | 40Ah |
| Cycle life | ≥2000 (100% DOD) |
| Shipment Voltage | 76.8~81.6V |
| Discharge cut-off voltage | ≤65V |
| Internal Impedance | ≤150mΩ |
| Warranty | 2 years |
| Brand Name | Topband |
| Model Number | TB7240F-S113A |
| Certification | ISO9001, ISO14001, MSDS |
| Place of Origin | China |
View Detail Information
Explore similar products
12 volt Deep Cycle Lithium Battery Pack 100Ah for Solar, Caravan, Marine
40Ah Capacity Rechargeable Lithium Ion Battery Deep Cycle TB1240F-S110C
Long Cycle Life Lithium Ion Battery Rechargeable , Lithium Deep Cycle Battery 12
12V 200Ah LiFePO4 Deep Cycle Lithium Battery Lithium 12v Deep Cycle Battery
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 450Mwh/year |
| Delivery Time | 2~4weeks for samples; 4~6weeks for mass production | Packaging Details | standard export carton |
| Material | LiFePO4 | Norminal voltage | 76.8V |
| Norminal capacity | 40Ah | Cycle life | ≥2000 (100% DOD) |
| Shipment Voltage | 76.8~81.6V | Discharge cut-off voltage | ≤65V |
| Internal Impedance | ≤150mΩ | Warranty | 2 years |
| Brand Name | Topband | Model Number | TB7240F-S113A |
| Certification | ISO9001, ISO14001, MSDS | Place of Origin | China |
| High Light | lithium iron phosphate deep cycle battery ,industrial deep cycle batteries | ||
| NO. | Items | Characteristics | Testing Methods | |
| 1 | Nominal Voltage | 76.8V | Follow GB/T18287-2013> | |
| 2 | Nominal Capacity | 40Ah | Follow | |
| 3 | Minimum Capacity | 38Ah | Follow | |
| 4 | Battery internal Impedance | Internal Impedance≤150mR | Internal Impedance Testing Machine(1kHz ) | |
| 5 | Shipment Voltage | 76.8~81.6V | Multi-meter | |
| 6 | Dimension | Length | 530x240x222mm | Vernier caliper |
| Width | ||||
| Height | ||||
| Gross weight | Approx. 27kg | electronic scale | ||
| 7 | Working Temperature | Charge | 0~45℃,45~85%RH | Temperature & Humidity Instruments |
| Discharge | -20~55℃,45~85%RH | |||
| 8 | Storage Temperature & Humidity Range | Short: above one month | -20~+55℃,45~85%RH | Temperature & Humidity Instruments |
| Medium: above three months | 0~+45℃,45~85%RH | |||
| Long:above one year | +5~+30℃,45~85%RH | |||
| 9 | Allowed maximum continuous charge current | 40A | Multi-meter | |
| 10 | Allowed maximum continuous discharge current | 50A | 170A(8S) | |
| 11 | Allowed maximum reverse charge voltage | NO Allowed | / | |
| 12 | Allowed maximum charge voltage | 87.6±0.2V | Multi-meter | |
| 13 | Discharge cut-off voltage | ≤65V | Multi-meter | |
| No. | Items | Standards | Testing Methods | |
| 1 | Vibration Testing | The appearance of battery should not leakage, break or explosion | Fix a charged battery on a vibrating table, vibrate it for 90 minutes in three mutually perpendicular directions at the 0.8mm resonance. The frequency is to be varied at the rate of 1hz/min between 10 and 55 hertz. | |
| 2 | High Temperature Discharge Testing | The battery should be no remarkable breakage, distortion. Discharge time should not less than 255mins | Place a full charged battery under the environments of 55℃ for 2 hours. Discharge it at the current of 200mA to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours. | |
| 3 | Low Temperature Discharge Testing | The battery should be no remarkable breakage, distortion. Discharge time should not less than 180 minute | Place a full charged battery under the environments of -20℃ for 15-24 hours. Discharge it at the current of 200mA to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours. | |
| 4 | Constant Humidity & Temperature Testing | The battery should be no remarkable breakage, distortion. Discharge time should not less than180mins | Place a full charged battery under the environments of 40℃ and 90% - 95%RH for 48 hours. And keep it in the room temperature for 2 hours. Then discharge it at the current of 200mA to the cut-off voltage. | |
| 5 | High & Low Temperature Storage | The battery should be no remarkable breakage, distortion. And charge/discharge normally | Place a full charged battery in a oven with 55±2℃ for2 hours, then keep it under 20±5℃ for 4hrs, then place it in a oven with -20±2℃ for 2 hours, then keep for 4 hours under 20±5℃, cycle as high temperature-normal temperature-low temperature-normal temperature-high temperature for 10 times | |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1996
Total Annual:
240million-250million
Employee Number:
5000~5500
Ecer Certification:
Active Member
Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007. After years of rapid development, now Topband takes lithium battery as the ... Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007. After years of rapid development, now Topband takes lithium battery as the ...
Get in touch with us