China factories

Chat Now Send Email
China factory - Shenzhen Coolstart Refrigeration Equipment Co., Ltd

Shenzhen Coolstart Refrigeration Equipment Co., Ltd

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Refcomp SRC-S(W)-553 SRC-S-553-L4 Refrigeration Screw Compressor for HVAC Cold
China Refcomp SRC-S(W)-553 SRC-S-553-L4 Refrigeration Screw Compressor for HVAC Cold

  1. China Refcomp SRC-S(W)-553 SRC-S-553-L4 Refrigeration Screw Compressor for HVAC Cold
  2. China Refcomp SRC-S(W)-553 SRC-S-553-L4 Refrigeration Screw Compressor for HVAC Cold
  3. China Refcomp SRC-S(W)-553 SRC-S-553-L4 Refrigeration Screw Compressor for HVAC Cold

Refcomp SRC-S(W)-553 SRC-S-553-L4 Refrigeration Screw Compressor for HVAC Cold

  1. MOQ: 1
  2. Price: Discussed
  3. Get Latest Price
Refrigerant R22, R407C, R404A,R507
Delivery Time 1 Month
Horse Power 200HP/150KW
Packaging Details Wooden Case
Payment Terms T/T,Western Union
Application HVAC,Cold Room,Condensing Unit,Air Conditioning
Displacement 50/60Hz 600/720 m³/hr
Energy regulation 100%,75%,50%,25%(stepless 100%-25%)
Voltage 400V/3/50Hz-460V/3/60Hz
Supply Ability 100000Pcs/Year
Model Number SRC-S(W)-553,SRC-S-553-L4
Brand Name Refcomp
Place of Origin China
Certification CE

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Refrigerant R22, R407C, R404A,R507 Delivery Time 1 Month
Horse Power 200HP/150KW Packaging Details Wooden Case
Payment Terms T/T,Western Union Application HVAC,Cold Room,Condensing Unit,Air Conditioning
Displacement 50/60Hz 600/720 m³/hr Energy regulation 100%,75%,50%,25%(stepless 100%-25%)
Voltage 400V/3/50Hz-460V/3/60Hz Supply Ability 100000Pcs/Year
Model Number SRC-S(W)-553,SRC-S-553-L4 Brand Name Refcomp
Place of Origin China Certification CE
High Light Refrigeration screw compressor for HVAC ,Cold room screw compressor ,SRC-S-553-L4 refrigeration compressor
Refcomp class="lazy" src="/myres/images/load_icon.gif" data-original-S(W)-553 class="lazy" src="/myres/images/load_icon.gif" data-original-S-553-L4 Refrigeration Screw Compressor for HVAC Cold Room
Product Description
Advanced refrigeration screw compressor designed for HVAC cold room applications with superior efficiency and reliability.
  • Precision Rotor Profile: Advanced asymmetrical rotor geometry delivers smooth gas compression and superior volumetric efficiency.
  • Integrated Oil Separation: Built-in multi-stage oil separator reaches up to 99.85% separation efficiency, preserving heat exchange capacity.
  • Heavy-Duty Mechanical Design: High-precision angular contact and thrust bearings absorb high operational loads for continuous long-term durability.
  • Flexible Load Management: Supports step capacity control at 100%, 75%, 50%, and 25%, as well as stepless regulation down to 25% for efficient partial-load performance.

Product Image
Refcomp class=

Technical Parameters
Model class="lazy" src="/myres/images/load_icon.gif" data-original-S(W)-553 class="lazy" src="/myres/images/load_icon.gif" data-original-S-553-L4
Standard Motor Power 200HP/150KW
Displacement (50/60Hz) 600/720 m³/h
Weight 1030KG
Oil Charge 19L
Cooling Capacity Regulation 100%, 75%, 50%, 25% (stepless 100%-25%)
Electrical Heater 275W-230V-50/60Hz
Standard Motor 400/3/50Hz-460/3/60Hz
LRA Y/Δ 543/1645A 595/1802A
Technical diagram of Refcomp class=

Frequently Asked Questions
What technical data is required when requesting model selection for a screw compressor HVAC project?
Please provide required cooling capacity, operating evaporation and condensation temperatures, refrigerant choice, and electrical power supply specifications.
What installation precautions should be taken for suction and discharge piping?
Ensure pipe dimensions match the 80.0 mm discharge and 105.5 mm suction connections, install proper piping supports to isolate vibration, and verify check valve positioning to prevent liquid backflow.
What pre-start checks are mandatory prior to initial commissioning?
Confirm that the 19 dm³ oil level is clearly visible in the sight glass, verify proper signal wiring to the INT69 SNY protection unit, and allow the crankcase heater sufficient time to pre-heat before starting.
What maintenance steps help preserve operational stability during continuous duty?
Periodically inspect suction filter cleanliness, monitor oil pressure differential across internal flow paths, and test thermal protection trip circuits during scheduled maintenance.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Trading Company

  • Year Established:

    2001

  • Total Annual:

    50000000-10000000

  • Employee Number:

    80~100

  • Ecer Certification:

    Verified Supplier

Shenzhen Coolstart Refrigeration Equipment Co., Ltd. is a modern, professional refrigeration manufacturer with over 20 years of industry experience. We focus on the professional production and global sales of high-performance refrigeration equipment, serving as a reliable and cost-effective suppl... Shenzhen Coolstart Refrigeration Equipment Co., Ltd. is a modern, professional refrigeration manufacturer with over 20 years of industry experience. We focus on the professional production and global sales of high-performance refrigeration equipment, serving as a reliable and cost-effective suppl...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Coolstart Refrigeration Equipment Co., Ltd
  • Room 1801, Building 1, Kangli city, No. 66 Pingji Road, Longgang District, Shenzhen, Guangdong,China
  • https://www.refrigerationcoolingunit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement