| Radiolucent | Yes |
| Caster Diameter | 5 Inches |
| Deck Width | 24 Inches |
| Material | Non-magnetic Materials (e.g., Aluminum, Plastic, Fiberglass) |
| Surface Resistivity | Below 10⁹ Ohms |
| Payment Terms | T/T |
| Place Of Origin | China |
| Packaging Details | Wooden Case |
| Delivery Time | 7 Working Days |
| Supply Ability | 300 Pcs Per Month |
| Caster Type | Non-magnetic Stainless Steel Bearings |
| Certification | ISO |
| Model Number | 1-cf-30 |
| Brand Name | Jovi |
View Detail Information
Explore similar products
Total Length 78 Inches Non Magnetic Transport Stretcher Non Magnetic Aluminum
Anti-Ferrous Stretcher, Compatible with MRI Suites & Other Magnet-Free Zones,
Non-Magnetic Aluminum Alloy MRI-Compatible Stretcher with 240 Kg Max Load for
Total Length 78 Inches Non Magnetic Transport Stretcher Medical Patient Transfer
Product Specification
| Radiolucent | Yes | Caster Diameter | 5 Inches |
| Deck Width | 24 Inches | Material | Non-magnetic Materials (e.g., Aluminum, Plastic, Fiberglass) |
| Surface Resistivity | Below 10⁹ Ohms | Payment Terms | T/T |
| Place Of Origin | China | Packaging Details | Wooden Case |
| Delivery Time | 7 Working Days | Supply Ability | 300 Pcs Per Month |
| Caster Type | Non-magnetic Stainless Steel Bearings | Certification | ISO |
| Model Number | 1-cf-30 | Brand Name | Jovi |
Function: The MRI Stretcher with Radiation Shield is designed for patients undergoing MRI following a nuclear medicine procedure (e.g., PET/MRI, or MRI after a radioactive tracer injection). These patients emit low levels of ionizing radiation from the tracer, and while the levels are safe for the patient, staff exposure should be minimized using the ALARA (As Low As Reasonably Achievable) principle. This stretcher incorporates a lead-impregnated vinyl shield that attaches to the underside of the deck, absorbing a portion of the gamma radiation emitted from the patient. The shield is 0.5 mm lead-equivalent, reducing exposure by approximately 90 percent at typical PET tracer energies (511 keV). The shield is removable for cleaning and can be replaced if damaged. The stretcher also includes a radiation dosimeter holder (non-magnetic) that secures a staff dosimeter to the push handle, allowing monitoring of cumulative exposure.
Application: This stretcher is essential for PET/MRI facilities or any MRI department that performs scans on patients who have recently received radioactive tracers. Patients may come from nuclear medicine departments with residual tracer activity, and transporting them on a standard stretcher exposes staff to unnecessary radiation. The lead shield significantly reduces staff exposure during transport and positioning, without requiring staff to wear heavy lead aprons. The stretcher is also used for patients undergoing MRI-guided radiation therapy planning, where the patient may have fiducial markers or radioactive seeds in place. The shield is positioned under the patient, so it does not interfere with MRI imaging (the lead is outside the field of view for most scans). For whole-body scans where the shield might be in the field of view, the shield can be quickly removed.
Company Details
Year Established:
2010
Total Annual:
10000000-20000000
Employee Number:
100~500
Ecer Certification:
Verified Supplier
Jovvi(Beijing Hengtai Tech Co., Ltd) was established in 2010. The company adheres to the development concept of “integrity all over the world and conducts all continents”, adheres to the business policy of “strive to create greater value for customers”, and is committed... Jovvi(Beijing Hengtai Tech Co., Ltd) was established in 2010. The company adheres to the development concept of “integrity all over the world and conducts all continents”, adheres to the business policy of “strive to create greater value for customers”, and is committed...
Get in touch with us