| Payment Terms | T/T, Western Union, MoneyGram |
| Supply Ability | in stock |
| Delivery Time | 1~3 Working Days |
| Packaging Details | Carton |
| Product name | Vector Network Analyzer |
| Frequency | 10MHz-67GHz |
| Condition | Pre-Owned |
| Functions | Tested, in Full Working Conditions |
| Brand Name | Rohde and Schwarz |
| Model Number | ZVA67 |
| Place of Origin | Germany |
View Detail Information
Explore similar products
Keysight N5245B PNA-X Microwave Network Analyzer with 50 GHz Frequency 124 dB
Rohde & Schwarz ZVA24 Vector Network Analyzer 300 KHz to 24 GHz with Multiport
Durable R&S ZNB20 Vector Network Analyzer Multipurpose With Touchscreen
PNA Microwave Vector Network Analyzer Keysight Agilent E8362C
Product Specification
| Payment Terms | T/T, Western Union, MoneyGram | Supply Ability | in stock |
| Delivery Time | 1~3 Working Days | Packaging Details | Carton |
| Product name | Vector Network Analyzer | Frequency | 10MHz-67GHz |
| Condition | Pre-Owned | Functions | Tested, in Full Working Conditions |
| Brand Name | Rohde and Schwarz | Model Number | ZVA67 |
| Place of Origin | Germany | ||
| High Light | 2 ports Vector Network Analyzer ,Used Instruments Vector Network Analyzer | ||
| Option Code | Description |
|---|---|
| B-B18 | Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
| B-B18 | Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7 |
| B-B4 | Oven quartz (OCXO) for ZVA, ZVB, ZVT |
| B-K2 | Time domain (for ZVA, ZVB, ZVT) (software license) |
| B-K30 | Noise figure measurement on 2 port devices (for ZVA and ZVT) |
| B16 | Direct generator-receiver-access (for 2 port ZVA67) |
| B21 | Generator Step Attenuator Port 1, mechanical, 50dB in 10dB steps |
| B22 | Generator Step Attenuator Port 2, mechanical, 50dB in 10dB steps |
| B23 | Generator Step Attenuator Port 3, mechanical, 50dB in 10dB steps |
| B24 | Generator Step Attenuator Port 4, mechanical, 50dB in 10dB steps |
| B31 | Receiver Step Attenuator Port 1, mechanical, 35dB in 5dB steps |
| B32 | Receiver Step Attenuator Port 2, mechanical, 35dB in 5dB steps |
| B33 | Receiver Step Attenuator Port 3, mechanical, 35dB in 5dB steps |
| B34 | Receiver Step Attenuator Port 4, mechanical, 35dB in 5dB steps |
| B7 | Measurements on pulsed signals. Pulse profile, Recording time up to 25ms, up to 30MHz bandwidth |
| B8 | External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E |
| C3 | Three years of calibration coverage based on the R&S recommended calibration interval - includes test data |
| C5 | Five years of calibration coverage based on the R&S recommended calibration interval - includes test data |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| K10 | Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT |
| K17 | Increases the receiver bandwidth to 5MHz |
| K27 | Two internal pulse generators (for ZVA and ZVT) |
| K4 | Frequency converting measurement for ZVA and ZVT |
| K5 | Phase measurement on mixers (for ZVA, ZVT; ZVA/T-B16 and ZVA-K4 required) |
| K6 | True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports |
| K7 | Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth |
| K8 | Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4) |
| K9 | Measurement of group delay on frequency converters without LO access (for ZVA, ZVT) |
| R3 | Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| R5 | Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| ZV-Z218 | 1.85 mm calibration kit, fixed match, TOSM male and female calibration standards |
| ZV-Z96 | Flexible Precision Cable 50 Ohm 1.85mm(f)Rugged. to 1.85mm(m)Rugged.DUT; DC to 67GHz; 635mm(25 inch); 1 piece |
| ZVAB-B18 | Removable Flash Disc for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
| ZVAB-B4 | Oven quartz (OCXO) for ZVA, ZVB, ZVT |
| ZVAB-K2 | Time domain (for ZVA, ZVB, ZVT) |
| ZVAB-K30 | Noise figure measurement on linear and frequency converting 2 port devices (for ZVA, ZBV and ZVT) |
Company Details
Business Type:
Distributor/Wholesaler
Year Established:
2003
Total Annual:
500000-1000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China. Our highly skilled Sale Representatives can assist you with all of your new and refurbished test equipment needs, providing EMC test solutions and building your Anechoic ... Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China. Our highly skilled Sale Representatives can assist you with all of your new and refurbished test equipment needs, providing EMC test solutions and building your Anechoic ...
Get in touch with us
Leave a Message, we will call you back quickly!