Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Rohde Schwarz ESHS10 CISPR EMI Test Receiver with 9 kHz to 30 MHz Range CISPR 16","imgUrl":"https:\/\/img.chinax.com\/nimg\/73\/bc\/4124fd469f1db096116ec205f977-200x200-1\/rohde_schwarz_eshs10_cispr_emi_test_receiver_with_9_khz_to_30_mhz_range_cispr_16.jpg","attrs":{"Price":"Contact for Pricing","Detector Types":"Peak, Quasi-Peak, Average","Payment Terms":"T\/T,L\/C,PayPal","IF Bandwidth":"200 Hz, 9 kHz (CISPR)"}}
{"title":"Rohde And Schwarz EPL1000 EMI Test Receiver with 5 kHz to 30 MHz Frequency Range","imgUrl":"https:\/\/img.chinax.com\/nimg\/5c\/8f\/586ce1275f1aae48a7b93a60b233-200x200-1\/rohde_and_schwarz_epl1000_emi_test_receiver_with_5_khz_to_30_mhz_frequency_range_and_color_display_for_cispr16_1_1_compliance_test.jpg","attrs":{"Brand Name":"R&S","Model Number":"EPL1000","Place of Origin":"Germany","Minimum Order Quantity":"1 set"}}
{"title":"Rohde And Schwarz HFH2-Z2E Active Loop Antenna with 8.3 kHz to 30 MHz Frequency","imgUrl":"https:\/\/img.chinax.com\/nimg\/af\/3b\/1177c6cfc15a3c6765868fb94040-200x200-1\/rohde_and_schwarz_hfh2_z2e_active_loop_antenna_with_8_3_khz_to_30_mhz_frequency_high_sensitivity_and_integrated_overload_warning.jpg","attrs":{"Brand Name":"R&S","Model Number":"HFH2-Z2E","Place of Origin":"Germany","Minimum Order Quantity":"1 set"}}
{"title":"Keysight Agilent 8902A Measuring Receiver with 150 kHz to 1.3 GHz Range, \u00b1(0.015","imgUrl":"https:\/\/img.chinax.com\/nimg\/47\/5d\/e0cc0c5f2f1cc2b33ec1c1e7ec43-200x200-1\/keysight_agilent_8902a_measuring_receiver_with_150_khz_to_1_3_ghz_range_2c_c2_b1_280_015_db_2b_0_005_db_2f10_db_step_29_accuracy_2.jpg","attrs":{"Brand Name":"Keysight (Agilent)","Model Number":"8902A","Certification":"ISO17025","Place of Origin":"Malaysia"}}
{"title":"R&S\u00ae ESCI 7 EMI Emc Test Receiver 9 kHz - 7 GHz","imgUrl":"https:\/\/img.chinax.com\/nimg\/01\/d1\/e6b91ab78adcd9ee5985abfb0146-200x200-1\/r_26s_c2_ae_esci_7_emi_emc_test_receiver_9_khz_7_ghz.jpg","attrs":{"Brand Name":"Rohde & Schwarz","Model Number":"ESCI 7","Certification":"ISO 9001","Place of Origin":"German"}}
{"title":"EN Emc Receiver R&S\u00aeESL3 9 KHz To 3 GHz Compact","imgUrl":"https:\/\/img.chinax.com\/nimg\/73\/cf\/d9c9aad517d821793c86e8f6ac79-200x200-1\/en_emc_receiver_r_26s_c2_aeesl3_9_khz_to_3_ghz_compact.jpg","attrs":{"Brand Name":"Rohde & Schwarz","Model Number":"ESL3","Certification":"ISO 9001","Place of Origin":"German"}}
{"title":"R&S\u00aeESPI3 EMI Test Receiver 9 kHz to 3 GHz with CISPR Compliance and Fast","imgUrl":"https:\/\/img.chinax.com\/nimg\/0f\/e2\/a7fb403f1c9da9cb7eb0e51855ce-200x200-1\/r_26s_c2_aeespi3_emi_test_receiver_9_khz_to_3_ghz_with_cispr_compliance_and_fast_measurement_speed.jpg","attrs":{"Brand Name":"Rohde & Schwarz","Model Number":"ESPI3","Certification":"ISO 9001","Place of Origin":"German"}}
Rohde Schwarz ESHS10 CISPR EMI Test Receiver Conducted Emission 9 kHz to 30 MHz Laboratory Measurement Instrument
Rohde & Schwarz ESHS10 CISPR EMI Test Receiver — 9 kHz to 30 MHz
The Rohde & Schwarz ESHS10 is a CISPR-compliant EMI test receiver designed for conducted emission measurements from 9 kHz to 30 MHz. Equipped with peak, quasi-peak, and average detectors, a built-in preselector, and automated frequency scanning, the ESHS10 meets CISPR 16-1-1 requirements for EMC pre-compliance and full-compliance testing of electrical and electronic equipment.
Key Features
CISPR 16-1-1 Compliant: Full compliance with CISPR 16-1-1 and EN 55016 standards for conducted emission measurements using peak, quasi-peak, and average detectors.
Conducted Emission Coverage: 9 kHz to 30 MHz frequency range covering all conducted emission regulatory bands for power line and signal line EMC testing.
Built-in Preselector: Integrated tracking preselector improves dynamic range and suppresses out-of-band signals for accurate conducted emission measurements.
Multiple Detector Modes: Simultaneous peak, quasi-peak, and average detection with CISPR-defined time constants for standardized emission compliance testing.
Programmable Attenuation: 0 to 70 dB programmable RF attenuation with overload protection for safe connection to conducted emission test setups.
Automated Scanning: Built-in frequency scanning and measurement routines with limit line comparison for efficient EMC compliance testing.
EMC Compliance Testing
Conducted Emissions: Ideal for measuring conducted disturbances on AC mains and signal lines per CISPR 11, 14-1, 22/32, and EN 55011/55022 standards.
LISN Integration: Compatible with standard Line Impedance Stabilization Networks (LISNs) and artificial mains networks (AMNs) for conducted emission measurements.
Limit Line Comparison: Built-in limit line storage and pass/fail evaluation for CISPR and EN conducted emission limits.
Report Generation: Automated measurement reports with trace data, limit comparison, and test configuration documentation.
Automation and Remote Control
GPIB (IEEE-488.2) interface for fully automated EMC test system integration with SCPI command support.
RS-232 serial interface for simple remote control and data logging applications.
Compatible with R&S EMC32 and other EMC test automation software for comprehensive compliance testing and reporting.
Applications
Conducted emission pre-compliance and full-compliance testing
EMC testing of household appliances, lighting equipment, and power tools (CISPR 14-1)
IT and multimedia equipment testing (CISPR 22/32)
Industrial, scientific, and medical (ISM) equipment testing (CISPR 11)
Automotive component conducted emission testing
EMC laboratory and test house standard reference instrument
Specifications Summary
Frequency Range
9 kHz to 30 MHz
Compliance
CISPR 16-1-1, EN 55016
Detectors
Peak, Quasi-Peak, Average
IF Bandwidth
200 Hz, 9 kHz (CISPR)
Preselector
Built-in Tracking
Attenuation
0-70 dB, Programmable
Interfaces
GPIB (IEEE-488), RS-232
Weight
12 kg (26.5 lbs)
Contact us today for a competitive quotation, calibration certificates, and worldwide shipping. Our technical team provides comprehensive pre-sales consultation and after-sales support for all Rohde & Schwarz EMC test instruments.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Distributor/Wholesaler
Year Established:
2003
Total Annual:
500000-1000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China.
Our highly skilled Sale Representatives can assist you with all of your
new and refurbished test equipment needs, providing EMC test solutions
and building your Anechoic ... Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China.
Our highly skilled Sale Representatives can assist you with all of your
new and refurbished test equipment needs, providing EMC test solutions
and building your Anechoic ...