| System Dynamic Range | 117 dB (0.5-2 GHz), 120 dB (2-10 GHz), 121 dB (10-20 GHz) |
| Frequency Resolution | 1 Hz |
| Power Range | -25 to +5 dBm (45 MHz-10 GHz), -24 to +3 dBm (10-20 GHz) |
| Weight | 29 kg net, 36 kg shipping |
| Dimensions | 267 x 426 x 427 mm |
| Phase Noise | -60 dBc at 1 kHz offset (10 MHz-10 GHz), -55 dBc (10-20 GHz) |
| Line Power | 100-240 V, 50/60/400 Hz, 350 W max |
| Measurement Channels | 32 independent channels |
| Operating Temperature | 0 C to +40 C |
| Series | Agilent / Keysight PNA Series Microwave Network Analyzers |
| Power Resolution | 0.01 dB |
| CPU | Intel 1.1 GHz Pentium M, 1 GB RAM |
| Storage Temperature | -40 C to +70 C |
| Type | Vector Network Analyzer (VNA) |
| Supported Options | 010 Time Domain, 014 Configurable Test Set, UNL Extended Power Range and Bias Tees, 080 Frequency Offset, 081 Reference Channel Switch, 082 Scalar Converter, 083 Frequency Converter, H08 Pulsed, H11 External IF Inputs |
| Test Ports | 2 ports, 3.5 mm male, 50 Ohm |
| Test Port Noise Floor | < -114 dBm (10 Hz IFBW, 0.5-2 GHz), < -120 dBm (10-20 GHz) |
| Power Level Accuracy | +/- 1.5 dB (45 MHz-10 GHz), +/- 2.0 dB (10-20 GHz) |
| Interfaces | GPIB IEEE 488.2, LAN 10Base-T, USB, SICL/LAN, DCOM |
| Safety | IEC/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1 |
| Delivery Time | 3-7 working days for stock, 15-25 days for bulk order |
| Nominal Output Power | 0 dBm standard |
| Calibration Types | Full 2-port, 1-port, response and isolation, TRL/TRM, scalar and vector mixer |
| Warranty | Per manufacturer, extended warranty available |
| Model | Agilent E8362B |
| Third Order Intercept | +24 dBm typical (0.5-20 GHz) |
| Points Per Sweep | 2 to 16,001 |
| Display | 8.4 in colour LCD, 640 x 480 |
| Payment Terms | T/T,L/C,Western Union |
| Supply Ability | 15 Pieces per Month |
| Trace Noise Magnitude | < 0.006 dB rms at 1 kHz IFBW |
| Receivers | 4 (A, B, R1, R2) |
| CW Accuracy | +/- 1 ppm |
| Receiver Dynamic Range | 119 dB (0.5-2 GHz), 122 dB (2-10 GHz), 125 dB (10-20 GHz) |
| Trace Noise Phase | < 0.060 deg rms at 1 kHz IFBW |
| Packaging Details | Factory foam-lined instrument carton with front panel protection, export-grade double-wall corrugated crate |
| Frequency Range | 10 MHz to 20 GHz |
| IF Bandwidth Range | 1 Hz to 40 kHz |
| Model Number | E8362B |
| Brand Name | Agilent / Keysight |
| Certification | CE, IEC/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1 |
| Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
Keysight E5080B 4-port Vector Network Analyzer with 9 kHz to 20 GHz Range and
Rohde & Schwarz ZVA24 Vector Network Analyzer 300 KHz to 24 GHz with Multiport
Durable R&S ZNB20 Vector Network Analyzer Multipurpose With Touchscreen
PNA Microwave Vector Network Analyzer Keysight Agilent E8362C
Product Specification
| System Dynamic Range | 117 dB (0.5-2 GHz), 120 dB (2-10 GHz), 121 dB (10-20 GHz) | Frequency Resolution | 1 Hz |
| Power Range | -25 to +5 dBm (45 MHz-10 GHz), -24 to +3 dBm (10-20 GHz) | Weight | 29 kg net, 36 kg shipping |
| Dimensions | 267 x 426 x 427 mm | Phase Noise | -60 dBc at 1 kHz offset (10 MHz-10 GHz), -55 dBc (10-20 GHz) |
| Line Power | 100-240 V, 50/60/400 Hz, 350 W max | Measurement Channels | 32 independent channels |
| Operating Temperature | 0 C to +40 C | Series | Agilent / Keysight PNA Series Microwave Network Analyzers |
| Power Resolution | 0.01 dB | CPU | Intel 1.1 GHz Pentium M, 1 GB RAM |
| Storage Temperature | -40 C to +70 C | Type | Vector Network Analyzer (VNA) |
| Supported Options | 010 Time Domain, 014 Configurable Test Set, UNL Extended Power Range and Bias Tees, 080 Frequency Offset, 081 Reference Channel Switch, 082 Scalar Converter, 083 Frequency Converter, H08 Pulsed, H11 External IF Inputs | Test Ports | 2 ports, 3.5 mm male, 50 Ohm |
| Test Port Noise Floor | < -114 dBm (10 Hz IFBW, 0.5-2 GHz), < -120 dBm (10-20 GHz) | Power Level Accuracy | +/- 1.5 dB (45 MHz-10 GHz), +/- 2.0 dB (10-20 GHz) |
| Interfaces | GPIB IEEE 488.2, LAN 10Base-T, USB, SICL/LAN, DCOM | Safety | IEC/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1 |
| Delivery Time | 3-7 working days for stock, 15-25 days for bulk order | Nominal Output Power | 0 dBm standard |
| Calibration Types | Full 2-port, 1-port, response and isolation, TRL/TRM, scalar and vector mixer | Warranty | Per manufacturer, extended warranty available |
| Model | Agilent E8362B | Third Order Intercept | +24 dBm typical (0.5-20 GHz) |
| Points Per Sweep | 2 to 16,001 | Display | 8.4 in colour LCD, 640 x 480 |
| Payment Terms | T/T,L/C,Western Union | Supply Ability | 15 Pieces per Month |
| Trace Noise Magnitude | < 0.006 dB rms at 1 kHz IFBW | Receivers | 4 (A, B, R1, R2) |
| CW Accuracy | +/- 1 ppm | Receiver Dynamic Range | 119 dB (0.5-2 GHz), 122 dB (2-10 GHz), 125 dB (10-20 GHz) |
| Trace Noise Phase | < 0.060 deg rms at 1 kHz IFBW | Packaging Details | Factory foam-lined instrument carton with front panel protection, export-grade double-wall corrugated crate |
| Frequency Range | 10 MHz to 20 GHz | IF Bandwidth Range | 1 Hz to 40 kHz |
| Model Number | E8362B | Brand Name | Agilent / Keysight |
| Certification | CE, IEC/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1 | Place of Origin | Guangdong, China |
| High Light | 121 dB Dynamic Range 3.5 mm ,Four Receiver PNA Architecture ,0.006 dB rms Trace Noise | ||
The Agilent (now Keysight) E8362B is a 2-port PNA Series microwave vector network analyzer covering 10 MHz to 20 GHz with 3.5 mm test ports. It belongs to the four-receiver PNA microwave family that also includes the E8363B (40 GHz), E8364B (50 GHz) and E8361A (67 GHz), sharing the same firmware, calibration engine and user interface.
With 121 dB system dynamic range in the 10 to 20 GHz band and typical trace noise below 0.006 dB rms, the E8362B resolves deep stop-band rejection, high-Q filter skirts and low-level spurious responses that simpler analyzers miss. The four-receiver architecture (A, B, R1 and R2) supports true TRL and TRM calibration for on-wafer, in-fixture and waveguide environments, while the configurable test set and extended power range options allow the instrument to be tailored for active device measurement.
| Model | Agilent E8362B PNA Series microwave network analyzer |
| Frequency range | 10 MHz to 20 GHz |
| Test ports | 2 ports, 3.5 mm male, 50 Ω |
| Receivers | 4 (A, B, R1, R2) |
| Frequency resolution | 1 Hz |
| CW accuracy | ± 1 ppm |
| Frequency stability | ± 1 ppm 0 to 40 °C typical, ± 0.2 ppm/year typical |
| System dynamic range | 117 dB (500 MHz to 2 GHz), 120 dB (2 to 10 GHz), 121 dB (10 to 20 GHz) |
| Receiver dynamic range | 119 dB (500 MHz to 2 GHz), 122 dB (2 to 10 GHz), 125 dB (10 to 20 GHz) |
| Test port noise floor (10 Hz IFBW) | < -114 dBm (500 MHz to 2 GHz), < -117 dBm (2 to 10 GHz), < -120 dBm (10 to 20 GHz) |
| Trace noise magnitude | < 0.006 dB rms at 1 kHz IFBW (500 MHz to 20 GHz) |
| Trace noise phase | < 0.060° rms at 1 kHz IFBW (500 MHz to 20 GHz) |
| Nominal output power | 0 dBm (standard), power range -24 to +3 dB (10 to 20 GHz), -25 to +5 dB (45 MHz to 10 GHz) |
| Power level accuracy | ± 1.5 dB (45 MHz to 10 GHz), ± 2.0 dB (10 to 20 GHz) |
| Power resolution | 0.01 dB |
| Third order intercept | +24 dBm typical (500 MHz to 20 GHz, 100 kHz to 5 MHz tone spacing) |
| Phase noise (1 kHz offset) | -60 dBc typical (10 MHz to 10 GHz), -55 dBc typical (10 to 20 GHz) |
| Receiver compression | < 0.1 dB at -5 dBm and < 0.45 dB at +5 dBm (10 MHz to 20 GHz) |
| Damage input level | 30 dBm or ± 40 VDC at test ports |
| IF bandwidth range | 1 Hz to 40 kHz nominal |
| Display | 8.4 in diagonal colour active matrix LCD, 640 x 480 |
| Display range | Magnitude ± 200 dB, phase ± 500° |
| Display resolution | 0.001 dB/div magnitude, 0.01°/div phase |
| Measurement channels | 32 independent channels |
| Windows and traces | Up to 16 windows, 4 active plus 4 memory traces per window, 10 markers per trace |
| Points per sweep | 2 to 16,001 |
| Sweep types | Linear, CW, power, segment sweep |
| CPU | Intel 1.1 GHz Pentium M, 1 GB RAM |
| Interfaces | GPIB IEEE 488.2, LAN 10Base-T, USB, SICL/LAN, DCOM, COM |
| Line power | 100-120 V at 50/60/400 Hz, 220-240 V at 50/60 Hz, auto switching, 350 W maximum |
| Dimensions | 267 mm H x 426 mm W x 427 mm D (cabinet, excluding front and rear hardware) |
| Weight | 29 kg net, 36 kg shipping, nominal |
| Operating temperature | 0 °C to +40 °C |
| Storage temperature | -40 °C to +70 °C |
| EMC | IEC/EN 61326, CISPR 11 Group 1 Class A, AS/NZS CISPR 11, ICES/NMB-001 |
| Safety | IEC/EN 61010-1, CSA C22.2 No. 61010-1, UL 61010-1 |
Full two-port calibration removes directivity, source match, load match, reflection and transmission tracking plus crosstalk systematic errors. Available calibration types include frequency response, response and isolation, one-port, two-port, TRL/TRM and both scalar and vector mixer calibration, with interpolated error correction over the full frequency range.
Send us your measurement frequency range, device type and calibration kit in use and we will confirm the option configuration, calibration certificate status, lead time and shipping terms.
Company Details
Business Type:
Distributor/Wholesaler
Year Established:
2003
Total Annual:
500000-1000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China. Our highly skilled Sale Representatives can assist you with all of your new and refurbished test equipment needs, providing EMC test solutions and building your Anechoic ... Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China. Our highly skilled Sale Representatives can assist you with all of your new and refurbished test equipment needs, providing EMC test solutions and building your Anechoic ...
Get in touch with us
Leave a Message, we will call you back quickly!