| Payment Terms | T/T |
| Supply Ability | in stock |
| Product name | True-RMS Clamp Meter |
| Condition | New |
| Voltage | to 1000 V AC or DC |
| Resistance | to 60 kΩ |
| Resolution | 0.1 A |
| Functions | Tested, in Full Working Conditions |
| Brand Name | Fluke |
| Model Number | 376FC |
| Place of Origin | USA |
View Detail Information
Explore similar products
Keysight 34405A 5 1/2 Digit Benchtop Multimeter with SCPI Language Compatibility
Keysight 4155C Semiconductor Parameter Analyzer with 10 Femtoamp Resolution 200V
Keysight 4156C Semiconductor Parameter Analyzer with 1 Femtoamp Resolution 200V
Keysight N1914B EPM Series Dual-Channel Power Meter with DC to 120 GHz Frequency
Product Specification
| Payment Terms | T/T | Supply Ability | in stock |
| Product name | True-RMS Clamp Meter | Condition | New |
| Voltage | to 1000 V AC or DC | Resistance | to 60 kΩ |
| Resolution | 0.1 A | Functions | Tested, in Full Working Conditions |
| Brand Name | Fluke | Model Number | 376FC |
| Place of Origin | USA | ||
| High Light | True-RMS Clamp Meter ,iFlex True-RMS Clamp Meter ,Fluke 376 FC Clamp Meter | ||
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
| General Specifications | |||
|---|---|---|---|
| AC Current via Jaw | |||
| Range | 999.9 A | ||
| Resolution | 0.1 A | ||
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) |
||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2 |
||
| AC Current via Flexible Current Probe | |||
| Range | 2500 A | ||
| Resolution | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
||
| Accuracy | 3% ±5 digits (5 - 500 Hz) | ||
| Crest Factor (50/60Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
||
| Flex Probe Specifications | |||
| i2500-10 Flex | i2500-18 Flex | i2500-36 Flex | |
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | 4.8 in (122.2 mm) |
| Error | ±0.5 % | ±0.5 % | ±0.5 % |
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | 5.3 in (133.6 mm) |
| Error | ±1.0 % | ±1.0 % | ±1.0 % |
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | 5.8 in (147.6 mm) |
| Error | ±2.0 % | ±2.0 % | ±2.0 % |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | |||
| DC Current | |||
| Range | 999.9 A | ||
| Resolution | 0.1 A | ||
| Accuracy | 2% ±5 digits | ||
| AC Voltage | |||
| Range | 1000 V | ||
| Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
||
| Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | ||
| DC Voltage | |||
| Range | 1000 V | ||
| Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
||
| Accuracy | 1% ±5 digits | ||
| mV DC | |||
| Range | 500.0 mV | ||
| Resolution | 0.1 mV | ||
| Accuracy | 1% ±5 digits | ||
| Frequency via Jaw | |||
| Range | 5.0 Hz to 500.0 Hz | ||
| Resolution | 0.1 Hz | ||
| Accuracy | 0.5% ±5 digits | ||
| Trigger level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A |
||
| Frequency via Flexible Current Probe | |||
| Range | 5.0 Hz to 500.0 Hz | ||
| Resolution | 0.1 Hz | ||
| Accuracy | 0.5% ±5 digits | ||
| Trigger level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A |
||
| Resistance | |||
| Range | 60 kΩ | ||
| Resolution | 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) |
||
| Accuracy | 1% ±5 digits | ||
| Capacitance | |||
| Range | 1000 μF | ||
| Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
||
| Accuracy | 1% ±4 digits | ||
Fluke 376 FC with 18-inch iFlex
Includes:
Fluke 376 FC with 36-inch iFlex
Includes:
Company Details
Business Type:
Distributor/Wholesaler
Year Established:
2003
Total Annual:
500000-1000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China. Our highly skilled Sale Representatives can assist you with all of your new and refurbished test equipment needs, providing EMC test solutions and building your Anechoic ... Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China. Our highly skilled Sale Representatives can assist you with all of your new and refurbished test equipment needs, providing EMC test solutions and building your Anechoic ...
Get in touch with us
Leave a Message, we will call you back quickly!