Payment Terms | T/T,PAYPAL |
Supply Ability | 3000 PCS/MONTH |
Delivery Time | 7 days for samples |
Packaging Details | 1pcs vibration sensor in each inner box , 50pcs/ctn |
Name | roller vibration measure |
Protocol | RION 68 protocol and MODBUS RTU protocol |
Power on/off repeatability | <2mg |
Input(VDD_VSS) | 9~36 VDC |
Output Interface | RS232/RS485/TTL |
material | stainless steel |
Brand Name | RION |
Model Number | AKG392-485 |
Certification | CE, ISO |
Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
AKF398 Current Output 4 - 20mA 3 Axis Vibration Detection Sensor
Output 0 - 5V Triaxial Accelerometer Vibration Detection Sensor
AKF398 triple axis vibraton meter analog output vibration sensor motor vibration
AKG39 4000Hz Output Triaxial Digital Accelerometer , RS232 MEMS Vibration Sensor
Product Specification
Payment Terms | T/T,PAYPAL | Supply Ability | 3000 PCS/MONTH |
Delivery Time | 7 days for samples | Packaging Details | 1pcs vibration sensor in each inner box , 50pcs/ctn |
Name | roller vibration measure | Protocol | RION 68 protocol and MODBUS RTU protocol |
Power on/off repeatability | <2mg | Input(VDD_VSS) | 9~36 VDC |
Output Interface | RS232/RS485/TTL | material | stainless steel |
Brand Name | RION | Model Number | AKG392-485 |
Certification | CE, ISO | Place of Origin | Guangdong, China |
High Light | MEMS Digital Accelerometer ,AKF392 MEMS Digital Accelerometer ,Bridge Monitoring Vibration Detection Sensor |
RION AKG392 MEMS Digital Accelerometer Three axis Vibration Sensor for Bridge Monitoring
▶ MAIN FEATURE
★ Three axes (X, Y, Z)
★ Output signal: RS232; RS485; TTL
★ Power supply voltage: 9~36V
★ Size: L34.3×W34.3×H38.5mm
★ Working temperature: -40°C ~ +85°C
★ Storage temperature: -40°C ~ +85°C
★Excellent deviation stability, good environmental performance (shock, vibration and temperature)
▶ APPLICATION
★ Medical equipment
★ Bridge
★ Large machinery, engines
★ Automobile
★ Road roller
★ Crash records, fatigue monitoring and prediction
★ Wind power generation
★ Low-frequency vibration and automatic monitoring
★ Traffic system monitoring, roadbed analysis and high-speed railway
fault detection
Specifications
AKG392 | PARAMETERS | UNIT | |||||
Range | ±2 | ±4 | ±8 | ±10 | ±20 | ±40 | g |
Bias calibration | <1 | <1 | <1 | <1 | <1 | <1 | mg |
Measure axis | X,Y,Z | X,Y,Z | X,Y,Z | X,Y,Z | X,Y,Z | X,Y,Z | axis |
Power on/off repeatability | <2 | <2 | <2 | <2 | <2 | <2 | mg(max) |
Bias temperature coefficient | 0.15 | 0.15 | 0.15 | 0.75 | 0.75 | 0.75 | %/℃(typical) |
Resolution/threshold (@ 1Hz) | < 1 | < 1 | < 1 | < 1 | < 1 | < 1 | mg(max) |
Non-linearity | <0.5 | <0.8 | <1 | <1 | <1 | <1 | % FS(max) |
Bandwidth (3DB) | 500 | 500 | 500 | 500 | 500 | 500 | Hz |
Cross axis sensitivity | 1 | 1 | 1 | 2 | 2 | 2 | % |
Transverse vibration sensitivity ratio | 1 | 1 | 2 | 5 | 5 | 5 | % |
Density of noise | 21 | 21 | 21 | 86.6 | 86.6 | 86.6 | μg/√Hz |
Resonance frequency | 2.4 | 2.4 | 2.4 | 5.5 | 5.5 | 5.5 | kHz |
Output rate | 5Hz,10Hz,25Hz,50Hz,100Hz,200Hz,500Hz,1000Hz | ||||||
Output Interface | RS232/RS485/TTL | ||||||
Protocol | RION 68 protocol and MODBUS RTU protocol | ||||||
Input(VDD_VSS) | 9~36 VDC | ||||||
Operating current consumption | <60mA @ 12 VDC | ||||||
Connector | Industry standard M12 connector | ||||||
Weight | Product net weight: 82g, Magnetic base: 48g, L-shaped adapter plate 20g | ||||||
Size | Product size: 34.3*34.3*38.5mm Magnetic adsorption base size: 34.23*34.23*6mm L-shaped adapter plate size: 36*44*15mm |
▶ COMMUNICATION PROTOCOL
The product includes 68 protocol and MODBUS RTU two protocols. The default configuration parameters of the protocol are as follows:
PROTOCOL | RION 68 PROTOCOL | MODBUS-RTU |
Address code | 0 | 1 |
Broadcast address | 255 | 0 |
Serial port baud rate | 9600 | 9600 |
Parity bit | No parity | Even parity |
Serial port start bit | 1 bit | 1 bit |
Serial port data length | 8 bits | 8 bits |
Serial port stop bit | 1 bit | 1 bit |
Output mode | Question and answer | Question and answer |
Data Format | Data format | Data format |
Data check method | Checksum | CRC16 |
RION 68 protocol and MODBUS protocol mutual switching method:
Open the serial port debugging assistant, select the baud rate 115200, no parity, stop bit 1, the connection port number, make the host computer send hexadecimal 0xAA regularly for every 10ms. Power on the product and reply "RION" or "MRTU" to indicate that the change to the corresponding protocol is successful. After the switch is successful, the parameters are all the above default parameters.
Size
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2008
Total Annual:
50000000-60000000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Shenzhen Rion Technology Co., Limited(RION for short) is a high-tech company specialized in design and manufacturing MEMS inclinometer, 3D compass. RION has excellent developing team both in software and hardware. In hardware, RION has the ability of manufacture and test advanced inertial navig... Shenzhen Rion Technology Co., Limited(RION for short) is a high-tech company specialized in design and manufacturing MEMS inclinometer, 3D compass. RION has excellent developing team both in software and hardware. In hardware, RION has the ability of manufacture and test advanced inertial navig...
Get in touch with us
Leave a Message, we will call you back quickly!