China factories

China factory - Jingte 'er Environmental Protection Engineering Co.,Ltd

Jingte 'er Environmental Protection Engineering Co.,Ltd

  • China,Zhengzhou ,Henan
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Automatic 3 ton of double-stage reverse osmosis equipment for Industrial
China Automatic 3 ton of double-stage reverse osmosis equipment for Industrial

  1. China Automatic 3 ton of double-stage reverse osmosis equipment for Industrial

Automatic 3 ton of double-stage reverse osmosis equipment for Industrial

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, T/T, Western Union, MoneyGram
Supply Ability 200 sets /month
Delivery Time 7 days
Packaging Details wooden case
Applicable Industries Other, Mineral/ Commercial Water Industry
Video Outgoing-inspection Provided
Control Automatic
Showroom Locaiton None
Warranty 1 year
Power 220/380v
Brand Name HYJB
Model Number 3 tons single-stage
Place of Origin Zhengzhou ,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, T/T, Western Union, MoneyGram Supply Ability 200 sets /month
Delivery Time 7 days Packaging Details wooden case
Applicable Industries Other, Mineral/ Commercial Water Industry Video Outgoing-inspection Provided
Control Automatic Showroom Locaiton None
Warranty 1 year Power 220/380v
Brand Name HYJB Model Number 3 tons single-stage
Place of Origin Zhengzhou ,China

Automatic 3 ton of double-stage reverse osmosis equipment for Industrial Applications

 

 

 

 

Product Description

 

Reverse osmosis water treatment equipment as a pure water filtration production of special equipment, the use of reverse osmosis membrane selective permeability principle, through the equipment of the high-pressure pump through the reverse osmosis membrane of the raw water to apply a certain pressure, so that the water molecules in the raw water can be dialyzed out through the membrane, while other inorganic salts, microorganisms and organic matter due to the reverse osmosis membrane on the retention of these substances can not pass through the membrane, so that you can obtain pure Non-ionized water.

 

Reverse osmosis (RO) is an important part of membrane separation technology, under the action of higher than the osmotic pressure of the solution, based on other substances can not pass through the semi-permeable membrane and these substances and water to leave.

 

 

 

Parameter Table

 

Model
Water Making Ability
Inlet Caliber
Effluent Caliber
Blowdown alCer
Size(mm)
Power
YSRO-0.5T
0.5m3/h
DN20
DN20
DN15
1500×600×1500
1.3kw
YSRO-1T
1m3/h
DN25
DN25
DN20
1700×600×1500
2.1kw
YSRO-2T
2m3/h
DN32
DN25
DN20
2500×1000×1950
4.4kw
YSRO-3T
3m3/h
DN40
DN32
DN25
2500×1200×2150
4.5kw
YSRO-5T
5m3/h
DN50
DN40
DN32
2500×1350×2150
7.0kw
YSRO-8T
8m3/h
DN50
DN50
DN40
3500×1500×2150
11kw
YSRO-10T
10m3/h
DN50
DN50
DN40
3500×1600×2300
15kw

 

 

 

 

 

Key Advantage

 

 

1. The reverse osmosis membrane is imported rolled composite membrane. Membrane material: aromatic polyacryl.


2. High water permeability and high desalination rate. Under normal circumstances ≥ 98%


3. High retention and removal of organic matter, colloids, particles, bacteria, viruses, heat sources and so on.


4. Small energy consumption, high water utilization rate, lower operating costs than other desalination equipment.


5. There is no phase change in the separation process, and it has reliable stability.


6. Small size of equipment, simple operation, easy maintenance, strong adaptability, long service life.

 

 

 

 

 

Maintenance

 

After a period of normal operation, membrane elements can become contaminated with suspended or insoluble material that may be present in the feed water. Cleaning should be carried out in a timely manner when the performance of the system decreases by 10% under standard conditions, or when scaling or fouling and plugging apparently occurs. Periodic water flushing and chemical dosing for cleaning can restore the performance of the membrane elements and extend their service life.

System in the short-term stop operation period, should be every 5 days flushing system, flushing after closing the valve to prevent scaling and clogging.

System out of operation for a long period of time (more than 30 days), add 1% sodium bisulfite solution to prevent bacterial propagation.

 

 

 

 

 

Product Display

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2016

  • Employee Number:

    80~100

  • Ecer Certification:

    Verified Supplier

Jingte’er.company is a professional enterprise involved in manufacturing and marketing the best quality water treatment equipment for a wide range and variety of customers home and abroad. It is located in Zhengzhou, Henan province, China. Now, over 90% of our workers and engineers have m... Jingte’er.company is a professional enterprise involved in manufacturing and marketing the best quality water treatment equipment for a wide range and variety of customers home and abroad. It is located in Zhengzhou, Henan province, China. Now, over 90% of our workers and engineers have m...

+ Read More

Get in touch with us

  • Reach Us
  • Jingte 'er Environmental Protection Engineering Co.,Ltd
  • Building 30, Zhengzhou Equipment Manufacturing Industrial Park, No.1 Science and Technology Road 2, Xingyang, Zhengzhou, Henan, China
  • https://www.ro-waterplant.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement