China Cable And Optical Cable Line Integrity Combustion And Fire Resistance Characteri
China Cable And Optical Cable Line Integrity Combustion And Fire Resistance Characteri

  1. China Cable And Optical Cable Line Integrity Combustion And Fire Resistance Characteri
  2. China Cable And Optical Cable Line Integrity Combustion And Fire Resistance Characteri
  3. China Cable And Optical Cable Line Integrity Combustion And Fire Resistance Characteri

Cable And Optical Cable Line Integrity Combustion And Fire Resistance Characteri

  1. MOQ: 1 Set
  2. Price: US$2000-$30000
  3. Get Latest Price
Payment Terms T/T, Cash.L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability 5 units per month
Delivery Time 10 Work Days
Packaging Details Wooden cases
Gas pressure gauges: Air 0-0.6MPa, gas 0-0.25MPa;
Timer: 0 to 99.99s/m/h can be set arbitrarily;
Ignition device: Automatic piezoelectric ignition;
Voltage regulator: Capacity 8KVA
Test voltage: Continuously adjustable from 100 to AC1000V
ammeter display range: 0-5A
Brand Name CHENGFENG
Model Number CF8422
Certification ISO,CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Cash.L/C, D/A, D/P, Western Union, MoneyGram Supply Ability 5 units per month
Delivery Time 10 Work Days Packaging Details Wooden cases
Gas pressure gauges: Air 0-0.6MPa, gas 0-0.25MPa; Timer: 0 to 99.99s/m/h can be set arbitrarily;
Ignition device: Automatic piezoelectric ignition; Voltage regulator: Capacity 8KVA
Test voltage: Continuously adjustable from 100 to AC1000V ammeter display range: 0-5A
Brand Name CHENGFENG Model Number CF8422
Certification ISO,CE Place of Origin China
High Light cable testing machine fire resistanceoptical cable line integrity testercable combustion characteristics testing equipment

I. Equipment Overview:
This equipment is used to determine whether cables and optical cables can continuously operate in the specified state when burning under the specified fire source and time
Ability.
Ii. Compliance with Standards
This testing machine complies with GB/T19216.11-2003/ EC60331-11:1999 "Test for Line Integrity of cables and optical cables under Flame Conditions - Part 11: The test apparatus - a separate fire supply with a flame temperature not lower than 750℃ is designed and fully complies with GB/T19216.21-2003/1 EC60331-21:1999 "Test for Line integrity of cables and optical cables under Flame Conditions - Part 21:" Test procedures and requirements ---- cables with rated voltage of 0.6/1.0kv and below ", GB/T19216.23-2003/1 EC60331-23:1999 "Test for line integrity of cables and optical cables under flame conditions - Part 23: Test procedures and requirements - "Data Cables" GB/T19216.25-2003/1 EC60331-25:1999 "Line integrity test of flat cables and optical cables under flame extinguishing conditions - Part 25: Test procedures and requirements ---- optical cables" test standard. It shall replace GB/T12666.6-1990 "Test Methods for Burning of wires and Cables - Part 6: Test methods for fire resistance characteristics of wires and cables" as of the date of implementation. Iii. Equipment Features
1. It adopts imported rotameters, blowtorches and Venturi mixers, ensuring precise flow control, stable and uniform flames, and consistent temperature
Good consistency;
2. Imported thermometers and thermocouples, with a temperature measurement error of no more than 1%.
3. The equipment is equipped with leakage, overcurrent and overvoltage protection devices. In case of a fault, it will automatically cut off the high-voltage source to ensure the safety of the equipment and operation
Personnel safety;
4. The equipment is equipped with an airflow barrier inside to ensure that the shape of the flame is not affected by the airflow.
5. The equipment is equipped with excellent exhaust and waste gas treatment devices, ensuring that the test exhaust gas will not pollute the laboratory environment.
6. All the equipment is made of 304 stainless steel, which is aesthetically pleasing and will not rust even after long-term use.
Iv. Equipment Composition
1. Design of the combustion chamber (see Figure 1
The entire cubic combustion chamber is formed by fixing double-layer SUS304 stainless steel materials on the stainless steel square tube bracket. The space between the inner and outer partitions of the combustion chamber is filled with insulation cotton. The dimensions of the combustion chamber are 3Mx3Mx3M, totaling 27 cubic meters.
2. Sample support: The sample is supported by two or three metal rings with an inner diameter of approximately 150mm, as shown in Figure 2
V. Main Technical Parameters
(1) Combustion device:
1. Blowtorch: It is a propane gas blowtorch with a nozzle nominal length of 500mm and a width of 15mm, equipped with a Venturi mixer. The nozzle has three rows of staggered drill holes with a nominal diameter of 1.32mm and a center distance of 3.2mm. See Figure 3;
2. Flowmeters: Rotameter (Air) : 100L/min, rotameter (propane) : 10L/min;
3. Gas pressure gauges: Air 0-0.6MPa, gas 0-0.25MPa;
4. Components of the blowtorch control system: pressure regulating valve, piezoelectric igniter, flameout device, thermometer, K-type thermocouple, gas source (provided by the customer), regulating valve, ignition device, gas pipeline, flowmeter, Venturi mixer, blowtorch, ball valve, air pipeline, compressed air (provided by the customer).
5. Timer: 0 to 99.99s/m/h can be set arbitrarily;
6. Ignition device: Automatic piezoelectric ignition;
7. Temperature controller: It has two K-type thermocouple measurement inputs, with a temperature range of 0 to 1200℃ that can be set arbitrarily.
(2) Line Load control Section: (As shown in Figure 4
Test transformer: One 8KVA capacity, three-phase 1000V output AC transformer;
Voltage regulator: Capacity 8KVA, input 380V, output adjustable from 0 to 400V;
Test voltage: Continuously adjustable from 100 to AC1000V;
Voltage and current display: Voltmeter display range: 0-2000V, ammeter display range: 0-5A.
Test current: Maximum 3A;
1- Transformer 2- Fuse (2A) L1, L2, L3 3- Connect to L3 (or L1 or L2) phase N
4- Support ring 5- Test conductor 6- Load and indication device (such as bulb) 7- Sample 8- Metal shielding
(3) Exhaust gas treatment device: The exhaust gas treatment adopts a spray-type gas absorption tower to absorb the smoke dust and harmful gases produced during combustion
The body can be shared with the bundled cable combustion testing machine or other combustion machines.
Build · Honest service

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2004

  • Total Annual:

    5000-8000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

CHENGFENG is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment 6. Plastic T... CHENGFENG is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment 6. Plastic T...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan Chengfeng Testing Equipment Co., Ltd
  • No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China
  • https://www.rubbertestequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement