| Payment Terms | T/T, Cash.L/C, D/A, D/P, Western Union, MoneyGram |
| Supply Ability | 5 units per month |
| Delivery Time | 10 Work Days |
| Packaging Details | Wooden cases |
| Overall dimensions | L800* W850* H1200mm |
| Rated voltage | AC 220V |
| Total weight | 160KG |
| Total power | ≤5.0kW |
| Heating power | ≤4.5kW |
| The fastest heating rate | 20℃/min |
| Temperature control accuracy | ≤0.5%FS |
| Sample size | digital display meter |
| Hot plate size | 370*370mm, cold plate: 300*300mm, 2 pieces, for easy replacement |
| Maximum loading pressure | 5000N |
| Brand Name | CHENGFENG |
| Model Number | CF8635A |
| Certification | ISO,CE |
| Place of Origin | China |
View Detail Information
Explore similar products
BS476-6 Building Materials And Structures Fire Propagation Index Tester
Shock, Vibration, Rain, Combustion Testing Machine, Fire Resistance, Water Spray
EN ISO 9239 Radiant Heat Source Method Test Combustion Chamber
EN 13823 Single Burner Testing Machine SBI Measurement Of Fire Resistance
Product Specification
| Payment Terms | T/T, Cash.L/C, D/A, D/P, Western Union, MoneyGram | Supply Ability | 5 units per month |
| Delivery Time | 10 Work Days | Packaging Details | Wooden cases |
| Overall dimensions | L800* W850* H1200mm | Rated voltage | AC 220V |
| Total weight | 160KG | Total power | ≤5.0kW |
| Heating power | ≤4.5kW | The fastest heating rate | 20℃/min |
| Temperature control accuracy | ≤0.5%FS | Sample size | digital display meter |
| Hot plate size | 370*370mm, cold plate: 300*300mm, 2 pieces, for easy replacement | Maximum loading pressure | 5000N |
| Brand Name | CHENGFENG | Model Number | CF8635A |
| Certification | ISO,CE | Place of Origin | China |
| High Light | thermal insulation material tester ,heat loss tester with warranty ,flammability testing equipment temperature range | ||
Overview
In order to meet the requirements of production processes and energy conservation and emission reduction, improve working conditions, enhance economic benefits, and ensure the quality of thermal insulation engineering design, pump equipment is designed in accordance with the GB 50264-2013 standard.
This equipment is suitable for measuring the heat loss of thermal insulation materials on the outer surface of industrial equipment and pipelines with temperatures ranging from -196℃ to 850℃.
It is not applicable to equipment and pipelines with special requirements in nuclear energy, aviation and aerospace systems, as well as buildings, cold storage facilities and buried pipelines.
Instrument reference standard
GBT 10294-2008 Determination of Steady-state Thermal Resistance and Related Properties of Thermal Insulation Materials - Protected
hot Plate Method
GB 50264-2013 Code for Design of Thermal Insulation Engineering of Industrial Equipment and Pipelines
Temperature Control System
It is mainly composed of heating wires, iron plates, etc., and is heated by a temperature instrument. The maximum heating
temperature in the temperature zone can reach up to 600 degrees Celsius
It can be used at 500 degrees Celsius for a long time
A total of 12 temperature collection channels are equipped. Among them, the heating temperature channel is a closed-loop control
of the temperature zone, with 5 temperature monitoring points set. The remaining heat protection hot plate is equipped with 2
temperature monitoring points, and the cold surface is arranged with 5 temperature measurement points.
Pressurization System
It is mainly composed of cylinders. The required pressure value is achieved by fine-tuning the air pressure, and the current
status is displayed in real time within the control system.
Cooling System
It is mainly composed of a chiller, thermocouples, etc. The chiller cools the heating part of the equipment. The thermocouple
detects the temperature of the bottom surface. After the test is completed, when the temperature of the bottom surface is greater
than 50℃, the system prompts "Turn on the chiller" to quickly cool the hot plate.
Working principle
The equipment is composed of a sample back temperature measurement plate, a constant temperature heating plate and a
pressurization system. The sample back temperature measurement plate is equipped with five temperature sensors to measure the back
temperature of the sample in real time. The constant temperature heating plate provides a stable high-temperature heat source, and
the pressurization system supplies a stable pressure to the sample, ensuring the reliability of the test.
2. The equipment has two functions: measuring the thermal conductivity of insulating materials and the amount of heat loss. It
first tests the thermal conductivity and then the amount of heat loss. Completed at the same workstation;
3. Calculate the heat loss:
Calculate the amount of heat loss in accordance with standard GB 50264-2013 5.4
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
5000-8000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
CHENGFENG is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment 6. Plastic T... CHENGFENG is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment 6. Plastic T...
Get in touch with us
Leave a Message, we will call you back quickly!