Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"Mid-Scale Fire Exposure Test Furnace for Measuring Fire Resistance and Fire","imgUrl":"https:\/\/img.chinax.com\/nimg\/a8\/a5\/90c79a4f252d2b0e7d85c81a8f13-200x200-1\/mid_scale_fire_exposure_test_furnace_for_measuring_fire_resistance_and_fire_endurance_properties_of_building_elements.jpg","attrs":{"Certification":"ISO,CE","Temperature range":"-40 \u2103 to+150 \u2103","Price":"Negotiate","Packaging Details":"Wooden cases"}}
{"title":"BS476-6 Building Materials And Structures Fire Spread Index Tester Is A Test","imgUrl":"https:\/\/img.chinax.com\/nimg\/cc\/07\/1fed4edcca1250fc93ea43d987ea-200x200-1\/bs476_6_building_materials_and_structures_fire_spread_index_tester_is_a_test_method_for_measuring_the_flame_spread_characteristics.jpg","attrs":{"Brand Name":"CHENGFENG","Model Number":"CF8298","Certification":"ISO,CE","Place of Origin":"China"}}
{"title":"Medium-Sized Fire Test Furnace Designed for Fire Endurance Performance Testing","imgUrl":"https:\/\/img.chinax.com\/nimg\/1b\/b1\/5a436b82b465393dd991df1438b9-200x200-1\/medium_sized_fire_test_furnace_designed_for_fire_endurance_performance_testing_of_various_building_structural_elements.jpg","attrs":{"Delivery Time":"10 Work Days","Temperature resolution":"0.01\u2103","Brand Name":"CHENGFENG","Equipment weight":"350KG"}}
{"title":"Medium Fire Endurance Test Furnace","imgUrl":"https:\/\/img.chinax.com\/nimg\/48\/9b\/7e660dfe834661f008070645ab1d-200x200-1\/medium_fire_endurance_test_furnace.jpg","attrs":{"Certification":"ISO,CE","Temperature range":"-40 \u2103 to+150 \u2103","Price":"Negotiate","Packaging Details":"Wooden cases"}}
{"title":"Moisture and Heat Resistance Testing Machine","imgUrl":"https:\/\/img.chinax.com\/nimg\/75\/c5\/9a8b07d6eeef3dd24b4ae4fbd1ae-200x200-1\/moisture_and_heat_resistance_testing_machine.jpg","attrs":{"Certification":"ISO,CE","Temperature range":"-40 \u2103 to+150 \u2103","Temperature fluctuations":"\u00b10.5\u2103","Delivery Time":"10 Work Days"}}
Integrated design of 19 inch standard cabinet, beautiful and elegant, easy to operate, avoiding interference factors such as vibration
Cone Heater - Within a truncated cone, 230V, 5000W, heat output ranging from 0 to 120 kW/m2
. The entire testing process is controlled by a computer with a 19 inch touch screen
It has functions such as automatic ignition, automatic timing, automatic gas cut-off and shutdown, and is equipped with online testing camera function to capture the entire combustion testing process; The computer software is equipped with a video detection interface and can automatically save to the computer.
Three K-type thermocouples and a three-stage PID temperature controller are used to regulate the temperature
Automatic Splitting Gate - Protect the sample area before testing to ensure stable initial quality measurement. Operators may have additional time to perform system testing before testing begins. For flammable samples, if there is no opening and closing mechanism, it is easy to burn prematurely. This extra time is very important for the operator
Sample holder - sample size 100mm x 100mm, thickness not exceeding 50mm;
Possess expansion functions/interfaces for subsequent combustion equipment and heat release measurement systems
The internal packaging of the gas analyzer contains CO ₂/CO standard gas, which can be automatically calibrated at full capacity through computer software without the need for external standard gas
Ignition system 2.1, 10kV spark igniter, equipped with a safety stop fire device. The igniter is automatically positioned through a lever connected to the shut-off mechanism 2.2, and the system automatically ignites; Automatic timing; Automatic shut-off and shutdown;
Exhaust system 3.1, composed of axial flow fan, stainless steel exhaust pipe, diffuser plate, smoke hood, exhaust pipe, orifice flowmeter and thermometer; 3.2. Made of stainless steel to extend its lifespan. Including cover, gas sample sampling needle, exhaust fan
Gas sampling system 4.1, including annular sampler, suction pump, particulate filter, cold trap, exhaust valve, moisture filter and CO ₂ filter 4.2, three-stage filter; Filtering accuracy of 0.5 μ m 4.3, cryogenic trap; Compressor refrigeration system; Control temperature from 0 to 5 ℃ 4.4, the sampler has 12 small holes opposite to the airflow direction; Equipped with smoke and dust filters inside; 685mm away from the smoke hood;
Measurement system 5.1, equipped with ABB original brand paramagnetic oxygen analyzer imported from Germany, with a range between 0-25%; Oxygen range between 0-100%, error<0.01%, repeatability<0.01%; Response time: 4S; 5.2. German imported ABB original brand paramagnetic oxygen analyzer CO ₂ range: 0~10%, error: 2% FS, repeatability<3%; CO range 0~1%, error: 2% FS, repeatability<3%; Response time: 2.5S; 5.3. Measurement accuracy error of smoke density using the American Soreb laser system: 2%; Use photodiodes, 0.5mW helium neon laser, primary and backup photodetectors. 5.4. Measure the weight changes of the test material during the testing process using high-precision load-bearing sensors. 5.5. Temperature control system: Equipped with Omega original brand thermocouples from the United States, with an accuracy of 0.1 degrees Celsius. Fast temperature collection speed and durable lifespan; 5.6. Adopting a micro differential pressure sensor imported from the United States, with accuracy of ± 1% FS and hysteresis of ± 0.1% FS; maximum linear pressure of 69Kpa; 5.7. American imported Methem thermopile heat flux meter - used to set the radiation level on the sample surface; And equipped with a water cooling system and a safety protection heat flow meter. The design range is 0-120 kW/m ², the accuracy of the heat flow meter is ± 3%, and the repeatability is ± 0.5%; 5.8. Configure Kofloc original brand quality flow controller from Japan: flow accuracy of 2%;
User operating system1. Labview control system specifically designed for experimental instruments, with a user-friendly interface, easy operation, and precise control; 2. The PID temperature control module is linked to the power adjustment module and controlled by a programmable controller for constant temperature regulation; 3. The signal acquisition and processing module is linked to the air flow circuit control module, and the output is calculated through the logic of a programmable controller to intelligently adjust the preset air speed; 4. The system provides query function. The system automatically stores the numbering, temperature curve, and data of the test samples into the database within the system; And can input the number of the tested sample, testing date, etc. for query.
Parameter specifications (1) Size 1800 (W) × 900 (D) × 2650 (H) mm (2) Power supply AC 220V, 50/60Hz, 30A (3) Exhaust furnace body: 24L/s, minimum exhaust rate: 50L/s (4) Tool methane, CO (0.8%)/CO ₂ (8%), nitrogen, computer, vacuum cleaner, compressed gas
Reference standard
- ISO 5660: Testing for fire reactions - Heat release rate, smoke production rate, and mass loss rate • ASTM E 1354: Standard test method for thermal and visible smoke release rate of materials • BS 476 Pt.15: Testing of building materials and building structures: - Method for testing product heat release rate • GB/T 16172-2007 Test method for heat release rate of building materials • NFPA 264,
Our company also sells other related products such as imported cone calorimeter, FTT cone calorimeter, and high-end cone calorimeter
Product Introduction -
Heat release is a core measurement parameter for evaluating the fire characteristics of materials and products. Cone calorimeter can meet all existing standards, including ISO 5660, ASTM E 1354, ASTM E 1474, ASTM E 1740, ASTM F 1550, ASTM D 6113, NFPA 264,CAN ULC 135 According to BS 476 Part 15, it is also possible to purchase in the form of components. This way, if the laboratory needs specific tests such as heat release, mass loss, smoke generation, etc., the required components can be purchased first, and then other instruments can be gradually added to the same test chamber to become complete specification instruments. This flexible feature is one of the many advantages of the conical calorimeter. The testing theory of a cone calorimeter is based on the fact that the amount of oxygen burned is directly proportional to the amount of pure calories burned. For every 1KG of oxygen burned, 13.1 MJ/kg of gas will be produced. The thermal emissions, ignition time, oxygen consumption rate, CO, CO2 generation rate, and gas flow of the test gas will all be measured.
1. Unique selling point: 12 years of professional research and development, only solving problems for customers. 2. Professional team: A technical research and development team with 12 years of experience, leading in professional knowledge and practical skills. 3. Quality assurance: The company strictly controls quality standards, meets customer standard requirements, and exceeds customer expectations. 4. Innovation ability: Develop products that meet customer needs, and years of experience make product development forward-looking and leading. 5. Competitive advantages: reliable quality, flexible and applicable equipment performance, reasonable equipment prices, high delivery speed, and guaranteed customer after-sales service. 6. Provide customized solutions for customers: fully understand customer needs, provide personalized solutions, and completely solve customer problems. 7. Reliability and credibility: The company operates steadily for a long time, winning the long-term trust of customers and solving their concerns.
Customer Photos
Packing & Delivery
FAQ
Q:Are you factory or trading company?
A:We are factory in Dongguan City, Guangdong Province,China.Near Shenzhen or Guangzhou.
Q:What kind of certificate you have?
A:ISO9001 Certification, CE Certification.
Q:What is the lead time of the product?
A: Generally 7-15 days after getting the deposit.
Q:How about the payment term?
A: T/T, by cash, western union, or L/C.
Q:How about the warranty term?
A:1 year warranty,The engineer can teach the machine on the spot.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
5000-8000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
CHENGFENG is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment
1. Fire Testing Equipment
2. Building Material Fire Tester
3. Wire and Cable Fire Tester
4. Environmental Test Chamber
5. Textile Testing Equipment
6. Plastic T... CHENGFENG is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment
1. Fire Testing Equipment
2. Building Material Fire Tester
3. Wire and Cable Fire Tester
4. Environmental Test Chamber
5. Textile Testing Equipment
6. Plastic T...