| Payment Terms | T/T |
| Delivery Time | 15 days |
| Warranty | 1 year |
| Display Type | LCD |
| Accuracy | +/- 0.5 PSI |
| Repeatability: | Measure the same sand sample, and the difference between the larger and smallest values of the ten measurements of ventilation time should not exceed 0.5 seconds |
| Measurement range: | 0.001-0.1 ㎡/g |
| Brand Name | MORITA |
| Model Number | QR-SMT |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Coating Surface Abrasion Tester Microcomputer Controlled Surface Performance
220V Raw Sand Specific Surface Area Tester Surface Performance Testing
Highly Accurate Surface Hardness Testing With Green Sand Surface Performance
Precision 60r/Min Surface Stability Tester For Molding Sand
Product Specification
| Payment Terms | T/T | Delivery Time | 15 days |
| Warranty | 1 year | Display Type | LCD |
| Accuracy | +/- 0.5 PSI | Repeatability: | Measure the same sand sample, and the difference between the larger and smallest values of the ten measurements of ventilation time should not exceed 0.5 seconds |
| Measurement range: | 0.001-0.1 ㎡/g | Brand Name | MORITA |
| Model Number | QR-SMT | Place of Origin | CHINA |
| High Light | surface resistivity tester ,LCD Display surface resistivity tester ,LCD Display surface resistance tester | ||
1, Overview
Specific surface area(SSA) refers to the total area per unit mass of material. Divided into two categories: external surface area and internal surface area. The national standard unit is square meters per gram. The ideal non porous material only has an external surface area,. This instrument adopts the principle of ventilation method to measure the time (t) required for air to pass through a certain amount of sand column, and then substitute the time (t) into the given formula to calculate the actual specific surface area of the silicon sand sample for casting.
This instrument measures the porosity and actual specific surface area of silicon sand (raw sand, recycled sand) for casting according to the GB/T 9442-1998 standard "Silicon Sand for Casting" and Appendix B "Method for Determining the Angular Factor of Silicon Sand for Casting". Using SM high-precision timing instrument, the timing accuracy is high, and it can be set to 999 seconds and 99 milliseconds. Infrared sensors have high sensitivity and strong anti-interference ability. Automated control system, one click completion of the entire measurement process.
2, Structure and principle of the instrument
1. Structure of the instrument: (see Figure 1)
![]()
2. Working principle of the instrument: (see Figure 2)
![]()
The working principle of the instrument is to remove the mud from the original sand through strong washing, and after drying, weigh 50 ± 0.01g and put it into a sand bearing glass scale test tube. It can also be sieved and a single sieve sand can be taken as the sample. Gently tap the test tube with a small wooden stick until the volume of sand no longer decreases, record the volume of sand V (ml), and measure or read the height of the sand column h (cm). Then fix the sand bearing test tube on the test tube seat and seal it. Turn on the power switch and observe if the timing instrument displays 000.00. Otherwise, press the up key (▲) to return to zero (because this meter has a power-off record keeping function). Press the "Start" button (the instrument will automatically complete the entire measurement process), and the three-way solenoid valve DZ and the exhaust fan will work simultaneously to raise the liquid level to the infrared control sensor K1. The solenoid valve DZ and the exhaust fan will stop working at the same time, and the instrument will automatically switch to timing measurement. When the float liquid level reaches the infrared timing sensor K2, the instrument will start timing, and when the liquid level reaches the infrared timing sensor K3, timing will stop. Record the timing time, and the test will end. Perform 5 consecutive tests, discard the larger and smallest values of the recorded time, and calculate the average time t. Substitute the measured time (t) into the formula to calculate the actual specific surface area of the measured sand.
3, Technical parameters
1. Measurement range: 0.001-0.1 ㎡/g
2. Timing range 0-99.9s
3. Power supply: 220V ± 10% 50Hz
4. Pipeline sealing: The liquid level drops by no more than 5mm within 10 minutes
5. Repeatability: Measure the same sand sample, and the difference between the larger and smallest values of the ten measurements of ventilation time should not exceed 0.5 seconds
Company Details
Business Type:
Manufacturer,Seller
Total Annual:
100-1000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Wuxi Qianrong Instrument Co., Ltd. is a high-tech enterprise specializing in analytical and testing instruments, with a particular emphasis on new product development and research, and excels in software design, updating, and improvement. The company's main products include precision measuring e... Wuxi Qianrong Instrument Co., Ltd. is a high-tech enterprise specializing in analytical and testing instruments, with a particular emphasis on new product development and research, and excels in software design, updating, and improvement. The company's main products include precision measuring e...