China factories

Chat Now Send Email
China factory - JIANGSU MORUITA  CO., LTD

JIANGSU MORUITA CO., LTD

  • China
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China QR-9 Direct Reading Optical Emission Spectrometer Machine For Quality Control
China QR-9 Direct Reading Optical Emission Spectrometer Machine For Quality Control

  1. China QR-9 Direct Reading Optical Emission Spectrometer Machine For Quality Control
  2. China QR-9 Direct Reading Optical Emission Spectrometer Machine For Quality Control

QR-9 Direct Reading Optical Emission Spectrometer Machine For Quality Control

  1. MOQ: 1 PC
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Supply Ability 100 pcs per month
Delivery Time 15 days
Packaging Details wooden case
Operating System Windows 10
Power Requirements 220V, 50/60Hz
Detector Type CCD
Model QR-9 Spectrometer
Brand Name MORITA
Model Number QR-9
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 100 pcs per month
Delivery Time 15 days Packaging Details wooden case
Operating System Windows 10 Power Requirements 220V, 50/60Hz
Detector Type CCD Model QR-9 Spectrometer
Brand Name MORITA Model Number QR-9
Place of Origin China
High Light Spectrometer Machine Direct ReadingSpectrometer Machine QR-9Full Spectrum optical emission spectrophotometer

QR-9 Full-Spectrum Direct-Reading Optical Emission Spectrometer For Quality Control In Metal Smelting QR-9

 

The QR-9 Full-Spectrum Direct-Reading Optical Emission Spectrometer (OES) is a high-performance analytical instrument specifically designed for the metal smelting industry, providing fast, precise, and reliable elemental analysis for quality monitoring, material classification, and process control. With a detection time of just 25 seconds and a broad wavelength range of 130–800 nm, the QR-9 enables rapid assessment of major and trace elements in metals and alloys, ensuring compliance with industry standards and optimizing production processes.


Product Introduction

Metal smelting requires strict control over elemental composition to ensure product quality and consistency. The QR-9 spectrometer integrates full-spectrum direct-reading technology with a high-resolution CCD detector to deliver accurate and reproducible measurements across a wide range of metallic elements. Featuring a vacuum optical chamber and digital excitation light source, the QR-9 reduces detection limits and minimizes measurement errors, making it an ideal instrument for smelters, laboratories, and quality assurance teams.

This advanced spectrometer replaces traditional bulky photomultiplier tube (PMT) designs with a full-digital CCD detection system, offering higher sensitivity, faster readout speeds, and superior long-term stability. The instrument is factory-calibrated with preconfigured work curves, enabling users to begin measurements immediately after installation.


Key Advantages

  • Rapid Detection – Complete elemental analysis in 25 seconds, significantly increasing production efficiency.

  • Wide Wavelength Coverage – Measures elements in the 130–800 nm range, enabling detection of both major and trace metals in smelting processes.

  • High Precision & Stability – CCD detector ensures reproducible results with minimal drift over long-term operation.

  • Vacuum Optical Chamber – Maintains clean, stable measurement conditions and reduces optical path losses.

  • Automatic Optical Path Calibration – Ensures correct spectral alignment and accurate peak identification without manual intervention.

  • Prefabricated Work Curves – Factory-optimized parameters allow immediate operation and reliable results.

  • Error Prevention System – Protects optical components and detectors from contamination, ensuring consistent performance.


Technical Specifications

Parameter Specification
Instrument Type Full-Spectrum Direct-Reading OES
Detection Time 25 seconds
Wavelength Range 130–800 nm
Detector High-resolution CCD, Multi-detector
Excitation Source Digital full-spectrum light source
Optical Chamber Vacuum design
Applicable Materials Metals and alloys
Working Temperature 10℃ – 35℃
Working Moisture 20% – 80%
Power Supply AC220V/50Hz (customizable)
Dimensions 860 mm (L) × 660 mm (W) × 360 mm (H)
Weight ~80 kg

Applications

  • Quality Monitoring in Metal Smelting – Ensures alloys and metals meet strict compositional requirements.

  • Process Control – Monitors elemental variations during smelting to optimize production parameters.

  • Material Grade Identification – Accurately classifies ferrous and non-ferrous alloys for further processing.

  • Research & Development – Supports alloy innovation and metallurgical studies.

  • Industrial Laboratory Analysis – Enables rapid, reliable testing for large-scale production environments.

  •  

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Total Annual:

    100-1000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Wuxi Qianrong Instrument Co., Ltd. is a high-tech enterprise specializing in analytical and testing instruments, with a particular emphasis on new product development and research, and excels in software design, updating, and improvement. The company's main products include precision measuring e... Wuxi Qianrong Instrument Co., Ltd. is a high-tech enterprise specializing in analytical and testing instruments, with a particular emphasis on new product development and research, and excels in software design, updating, and improvement. The company's main products include precision measuring e...

+ Read More

Get in touch with us

  • Reach Us
  • JIANGSU MORUITA CO., LTD
  • https://www.sand-tester.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement