China 30kV VLF Tester 0.1Hz Ultra Low Frequency High Voltage Withstand Test Equipment
China 30kV VLF Tester 0.1Hz Ultra Low Frequency High Voltage Withstand Test Equipment

  1. China 30kV VLF Tester 0.1Hz Ultra Low Frequency High Voltage Withstand Test Equipment
  2. China 30kV VLF Tester 0.1Hz Ultra Low Frequency High Voltage Withstand Test Equipment
  3. China 30kV VLF Tester 0.1Hz Ultra Low Frequency High Voltage Withstand Test Equipment

30kV VLF Tester 0.1Hz Ultra Low Frequency High Voltage Withstand Test Equipment

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Output Voltage 30kV
Operating Temperature -10℃~+40℃
Working Power Supply AC220V±5%, 50/60Hz
Delivery Time 30 work days
Payment Terms T/T,L/C
Load Capacity 0.5 μF at 0.1Hz, 1.1 μF at 0.05Hz, 2.2 μF at 0.02Hz, 5.5 μF at 0.01Hz
Packaging Details plywood case
Output Frequency 0.1Hz, 0.05Hz, 0.02Hz, 0.01Hz
Measurement Accuracy 3%
Model Number SXCDP
Brand Name Sansion
Certification CE SGS ISO9001
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Output Voltage 30kV Operating Temperature -10℃~+40℃
Working Power Supply AC220V±5%, 50/60Hz Delivery Time 30 work days
Payment Terms T/T,L/C Load Capacity 0.5 μF at 0.1Hz, 1.1 μF at 0.05Hz, 2.2 μF at 0.02Hz, 5.5 μF at 0.01Hz
Packaging Details plywood case Output Frequency 0.1Hz, 0.05Hz, 0.02Hz, 0.01Hz
Measurement Accuracy 3% Model Number SXCDP
Brand Name Sansion Certification CE SGS ISO9001
Place of Origin China
High Light 30kV VLF tester for power cable ,ultra low frequency high voltage tester ,VLF withstand test equipment

Product Description

SXCDP-30kV VLF AC Hipot Tester is a compact and intelligent very low frequency withstand voltage testing system designed for insulation testing of electrical equipment with relatively large equivalent capacitance, including power cables, power capacitors, large generators and motors.

The system provides selectable test frequencies of 0.1 Hz, 0.05 Hz, 0.02 Hz and 0.01 Hz, with a maximum output voltage of 30 kV. It integrates digital frequency conversion technology, microcomputer control, automatic voltage ramp-up/down, measurement and protection, making it suitable for both laboratory and outdoor field testing.

Key Features

  • Intelligent Automatic Operation
  • 7-Inch Touchscreen Control
  • Multiple Protection Functions
  • Low-Voltage Optical Isolation Control
  • Closed-Loop Feedback Control
  • Automatic Data Storage & Printing
  • Compact and Lightweight Design

Technical Specifications

Item Specification
Model SXCDP-30kV
Product Type Very Low Frequency AC Hipot Tester / VLF AC Withstand Voltage Tester
Input Power AC 220V ±5%, 50/60 Hz
Maximum Output Voltage 30 kV
Output Frequency 0.1 Hz / 0.05 Hz / 0.02 Hz / 0.01 Hz
Load Capacity at 0.1 Hz Max. 0.5 μF
Load Capacity at 0.05 Hz Max. 1.1 μF
Load Capacity at 0.02 Hz Max. 2.2 μF
Load Capacity at 0.01 Hz Max. 5.5 μF
Measurement Accuracy 3%
Positive/Negative Peak Voltage Error ≤3%
Voltage Waveform Distortion ≤5%
Operating Temperature -10°C to +40°C
Operating Humidity ≤85% RH
Display & Control 7-inch LCD touchscreen
Language Chinese / English

Typical Applications

Power Cable Testing
Suitable for withstand voltage testing of power cables, particularly applications where the tested object has relatively large equivalent capacitance.

Power Capacitor Testing
The VLF testing system can be used for withstand voltage testing of power capacitors.

Generator Testing
Suitable for insulation withstand voltage testing of large and medium-sized generators.

Motor Testing
Can be applied to withstand voltage testing of large and medium-sized motors.
The source document specifically identifies power cables, power capacitors, large and medium-sized generators and motors as representative applications.

FAQ

Q1:What is a VLF AC Hipot Tester?

A VLF AC Hipot Tester is a high-voltage withstand testing instrument that uses very low frequency AC voltage for insulation testing. The SXCDP-30kV supports four test frequencies from 0.1 Hz to 0.01 Hz.

Q2:What is the maximum output voltage of SXCDP-30kV?

The maximum output voltage is 30 kV.

Q3:Which frequencies does the SXCDP-30kV support?

It supports 0.1 Hz, 0.05 Hz, 0.02 Hz and 0.01 Hz.

Q4:What equipment can be tested with this VLF tester?

Power cables, power capacitors, large and medium-sized generators and motors.

Q5:What is the maximum test load at 0.1 Hz?

At 0.1 Hz, the maximum specified load capacity is 0.5 μF.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Total Annual:

    50000000-80000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.sansionpower.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement